Crestron Control Systems: CP4 vs CP4N vs DMPS Guide

Crestron CP4 4-Series control processor

Creation Networks |

Last updated November 6, 2026

The difference between a Crestron CP4 and a CP4N is one port. Both are 1 RU 4-Series control processors with 2 GB SDRAM and 8 GB flash and identical control I/O. The CP4N adds a second gigabit Ethernet port Crestron calls the CONTROL SUBNET — a dedicated LAN for Crestron devices that the processor runs as a DHCP server and can firewall off from the building network. Choose a DMPS all-in-one instead when the room needs switching, mic mixing, and amplification in one chassis and you can accept a 3-Series engine. This guide covers all three, what Crestron support covers versus what your integrator covers, and the contract term that matters more than the hardware.

Quick answer: The CP4 and CP4N are functionally identical 4-Series control processors - the CP4N just adds a dedicated CONTROL SUBNET Ethernet port for isolating Crestron devices from the building LAN. Choose a DMPS all-in-one instead when a room needs switching, mic mixing, and amplification in one chassis and can accept a lower-spec 3-Series engine. The term that matters more than any hardware choice: get the editable program source code named as a deliverable in your PO before final payment - without it, a future change means paying someone to rewrite the room from scratch.

What a 4-Series control processor does, and when a room needs one

A control processor is the room's logic. It holds a compiled program that watches inputs and drives outputs: power a display over RS-232, route a source, mute a mic, close a relay to drop a screen, read an occupancy sensor on a Versiport. Crestron's 4-Series manual states that “Up to 10 programs can communicate together while operating independently and simultaneously,” and that the systems support “Full network security protocols, including 802.1X, SSH, TLS, and Active Directory service,” plus SNMP and BACnet/IP.

Not every room needs one. A single-display huddle room with two laptop inputs and no shades or scheduling logic is better served by an auto-switching presentation switcher. Crestron's HD-PS622 documentation describes “Automatic input switching, automatic display control” based on “the last connected input or on an assigned routing priority,” and the unit runs without a control processor. Add a processor for conditional behavior: multiple displays with different routing rules, combine/divide walls, DSP presets, environmental control, or status reporting. There is a middle case as well. When the real requirement is audio — mic mixing, echo cancellation, zone routing — with only light logic on top, a networked DSP with a control engine in the same box, such as the QSC Core Nano Q-SYS processor, covers both jobs and removes a device from the rack. Which side of that line a room falls on is a design question, and it belongs in AV system design and consulting before the BOM is locked. Crestron's MC4 is the middle option — PoE-powered at 7 W typical, 1.07 in. high, one RS-232 COM, four IR outputs, two relays, two Versiports.

Crestron CP4 4-Series control processor

Crestron CP4 vs CP4N: what is the actual difference?

Per Crestron's CP4 and CP4N manual the two are “functionally similar,” and the CP4N's distinguishing feature is that “An isolated control subnet port provides a Gigabit Ethernet LAN dedicated to Crestron devices.” Crestron's specification pages confirm it. For the Crestron CP4 4-Series control system, Crestron lists “(1) 8-pin RJ-45 connector, female; 100BASE-TX/1000BASE-T Ethernet port” and no control subnet. For the Crestron CP4N 4-Series control system, it lists that same LAN port plus a second, separately labeled “CONTROL SUBNET” port of the same type.

Crestron CP4N 4-Series control processor with a dedicated control subnet port

Crestron's 4-Series manual describes what that port buys you: “dedicated communication between the control system and Crestron Ethernet devices without interference from other network traffic on the LAN,” where “The control system acts as a DHCP server to all devices connected to the Control Subnet.” It can also be sealed — “When in isolation mode, the firewall is configured so that no communication can occur between the LAN and devices on the Control Subnet.” The AV4 and PRO4 carry four such ports with PoE+; the CP4N has one.

Practical rule for IT: buy the CP4N when the network team does not want to manage addresses for touch panels, sensors, and DM endpoints, or when policy keeps AV devices off the production VLAN. Buy the CP4 when the network team owns addressing anyway. Either way that port is a single uplink, not a switch — a room with several Crestron Ethernet devices still needs a switch downstream. And if the campus standard is heading a different direction, that is a fair time to ask the question: an Extron control system does the same job with a different programming toolchain, and standardising a building on one platform is usually worth more than picking the better processor room by room.

When a DMPS all-in-one makes more sense than a separate processor plus switcher

A DMPS puts the control engine, video matrix, mic mixer, DSP, and amplifier in one chassis. For a front-of-room space with local speakers and a few wired mics, that consolidation is real: fewer boxes, fewer power supplies, fewer interconnects to commission, one firmware target.

The trade is the control engine. Crestron's specifications for the DMPS3-4K-350-C and DMPS3-4K-250-C list a “Crestron 3-Series; real-time, preemptive, multi-threaded/multitasking kernel” with 512 MB SDRAM and 4 GB flash — a quarter of the RAM and half the flash of a CP4. If the room needs the 4-Series security stack or program headroom, a separate processor plus switcher is the better build. If it is a classroom with predictable behavior, the DMPS is fewer things to fail.

Crestron DMPS3-4K-350-C 3-Series 4K DigitalMedia presentation system
Specification CP4 CP4N DMPS3-4K-350-C
Control engine 4-Series 4-Series 3-Series
SDRAM / flash 2 GB / 8 GB 2 GB / 8 GB 512 MB / 4 GB
LAN ports (1) 100BASE-TX/1000BASE-T (1) LAN + (1) CONTROL SUBNET LAN, dedicated Control Subnet with PoE, CONTENT LAN IN
Video switching None None 9x4 matrix; 6 HDMI + 2 DM 8G+ + streaming/AirMedia in; 2 HDMI + 2 DM 8G+ out
Audio None None 6-channel mic mixer; 10-band graphic and 4-band parametric EQ per output
Amplifier None None 25 W RMS per channel @ 4 or 8 Ω, or 50 W RMS @ 70 or 100 V
COM ports COM 1 RS-232/422/485; COM 2–3 RS-232, to 115.2k baud Same as CP4 (2) RS-232
IR outputs (8), to 1.2 MHz (8), to 1.2 MHz (4)
Relays (8) normally open, 1 A @ 30 VAC/VDC (8) normally open, 1 A @ 30 VAC/VDC (4)
Versiport I/O (8) digital I/O or analog input (8) digital I/O or analog input (4) digital input
Rack space 1 RU 1 RU 3 RU
Power 24 VDC, PW-2420RU included; 15 W 24 VDC, PW-2420RU included; 15 W 100–240 VAC; 93 W typical, 72 W idle

All figures come from Crestron's published specifications. Note that the DMPS catalog is now short: Crestron's DMPS3-4K end-of-sale notice lists the DMPS3-300-C, DMPS3-4K-50, DMPS3-4K-100-C, DMPS3-4K-150-C, and the AirMedia-bundled 250-C and 350-C part numbers as discontinued, with an “End of Sale Announcement Date” of 7/1/2022 and an “End of Support Date” of 9/30/2025. The DMPS3-4K-250-C and DMPS3-4K-350-C remain the two live models, with AirMedia moving to a separate SW-DMPS3-AIRMEDIA license.

Who programs it, and who owns the source code?

The processor is a commodity. Two integrators can quote the identical CP4N and deliver rooms that feel nothing alike, because the program is where behavior lives. Put the programmer in the proposal by name, with their Crestron certification level, and ask how many programming hours are in the number. “Programming included” is a place for a change order to hide.

Then handle the part almost nobody puts in writing.

Require, in the purchase order, that the customer receives the editable source code and documentation at project closeout. Not the compiled program on the processor — the source: SIMPL Windows or SIMPL# project files, touch panel project files, DSP configuration files, device credentials, the IP table, and as-built drawings. A compiled program cannot be edited. If the only source sits on a laptop belonging to a programmer who has left the integrator, and that integrator will not release it, your options are to pay to have the room reverse-engineered and rewritten from scratch, or to live with the room exactly as it is until you replace the hardware. Both are expensive, and both are avoidable with one sentence in a PO.

Public agencies and universities have the strongest claim here and use it the least. Write it as a deliverable with the same weight as the hardware: source files, credentials, and as-builts to a named repository before final payment, and again after any field modification. Escrow is a fair middle ground if the integrator objects on IP grounds — silence on the question is the one answer you cannot accept. It is the highest-value term an IT director can add to an AV contract, and it costs nothing.

What does “Crestron support” actually cover?

Two different things get called Crestron support, and conflating them is how rooms sit broken for a week.

Manufacturer support is Crestron True Blue Support at 1-888-CRESTRON. Crestron's support site lists hours of Monday–Friday, 8:45 AM to 8:00 PM EST, emergency support 24/7, and phone, email, chat, and forum channels; RMAs run through the same portal. True Blue handles hardware, firmware, the OS, and diagnostics on Crestron products. It does not own your room's program, your third-party drivers, or your network configuration. On Crestron Flex room systems you can buy a deeper layer of that coverage directly from the manufacturer with Crestron UC-FLEXCARE premium support, which is worth knowing about because people often assume a service agreement with their integrator already includes it.

Integrator support is everything else, and it is the support that actually fixes rooms: program changes, driver updates when a display model changes, touch panel edits, firmware planning, on-site labor. This layer lapses quietly — an integrator gets acquired, a programmer leaves, a service agreement is not renewed, and nobody notices until a board meeting fails. Ask the response time, whether it covers after-hours, whether it includes remote access and how that access is secured, and who the backup programmer is.

Lifecycle is the third piece, and Crestron publishes it. In both notices cited here, end of support lands three years after the expected end of new sales: the 3-Series notice sets 3/31/2021 as the expected last order date and states that after 3/31/2024 “Crestron will not issue any firmware or software updates, security/bug patches or OS compatibility fixes.” The DMPS3-4K notice pairs 9/30/2022 with 9/30/2025. Keep a spreadsheet of model, firmware, install date, and end-of-support date for every processor you own. Past end of support a processor keeps working and stops receiving security patches — a decision for your security team, not a surprise. Replacements sit in our Crestron control systems catalog.

Installation note: rack units, power, and where the processor should live

The CP4 and CP4N each occupy 1 RU in a 19-inch rack; Crestron's instructions call for removing six screws to attach the rack ears, and four adhesive rubber feet ship in the box for freestanding use. Power comes from the included 24 VDC PW-2420RU pack or from Cresnet network power via the NET port. Crestron is explicit on grounding: “Connect the chassis ground lug to a known earth ground circuit (such as building steel) to ensure that the control system is grounded properly,” and “Apply power after all connections have been made.”

Two things estimators miss. First, heat load is trivial for the processor and not for the all-in-one: 15 W is roughly 51 BTU/hr, while the DMPS3-4K-350-C at 93 W typical is about 317 BTU/hr in a 3 RU chassis — size rack ventilation off the DMPS, not the CP4. Second, and more costly: the processor belongs in the room's own rack or credenza, not a distant IDF. Its 8 IR outputs, 8 relays, 8 Versiports, and 3 COM ports are copper home runs landing on 3.5 mm terminal blocks, and none of them travel over the network. Put a CP4N in a closet two floors away and every relay-controlled screen and RS-232-controlled display needs a run back to that closet, or a DM endpoint at the room to break the signals out locally. Decide processor location during rough-in, while conduit is cheap.

One more for the CP4N, from Crestron's manual: “Do not connect the CONTROL SUBNET port to the LAN.” Label it at the patch panel; it gets cross-patched on every job where it is not.

Frequently asked questions

What is the difference between the Crestron CP4 and CP4N?

The CP4N adds a dedicated CONTROL SUBNET gigabit Ethernet port that the CP4 does not have. Crestron's manual describes it as an isolated Gigabit Ethernet LAN dedicated to Crestron devices, on which the processor acts as a DHCP server and which can be firewalled off from the building LAN in isolation mode. Memory, COM ports, IR outputs, relays, Versiports, rack space, and power are the same on both.

Do I need a Crestron control processor for a small conference room?

Often not. With one display, a couple of wired inputs, and no lighting, shades, scheduling, or combine logic, an auto-switching presentation switcher such as the HD-PS622 handles input selection and display control without a processor. Add a processor for conditional behavior, multiple displays with different routing, DSP presets, environmental control, or status reporting.

Who provides Crestron support, Crestron or my integrator?

Both, for different things. Crestron True Blue Support at 1-888-CRESTRON covers Crestron hardware, firmware, OS, diagnostics, and RMAs, with published hours of Monday–Friday 8:45 AM to 8:00 PM EST and 24/7 emergency support. Your integrator covers the room program, third-party drivers, touch panel layouts, commissioning, network configuration, and on-site labor. Most broken-room calls are integrator work.

Do I own the Crestron program source code for my rooms?

Only if your contract says so. Ask for the editable source — SIMPL Windows or SIMPL# project files, touch panel projects, DSP configuration files, device credentials, IP table, and as-builts — as a named deliverable due before final payment, and again after any field modification. Without it, a future change means paying someone to rewrite the room from scratch.

Can I plug the CP4N CONTROL SUBNET port into my building network?

No. Crestron's manual says not to connect the CONTROL SUBNET port to the LAN. That port serves a separate network for Crestron devices, with the processor acting as its DHCP server. The LAN port is the one that connects to the building network. Label both at the patch panel so they are not cross-patched.

How much power does a Crestron CP4 or CP4N use?

Crestron lists 15 W for each, powered from the included 24 VDC PW-2420RU power pack or from Cresnet network power. That is roughly 51 BTU/hr, which is why rack ventilation is sized off an all-in-one DMPS at 93 W typical rather than off the processor.

Related Resources

Creation Networks, Inc. — nationwide commercial AV integrator, CTS-D certified, headquartered in Incline Village, NV with a California office in Concord. Design, engineering, programming, installation, and support from a single point of contact since 2006. Call 888-230-3661 or email sales@creationnetworks.net.

Get Started

Let's Talk About Your Crestron Control Rooms

Tell us about your rooms and what runs them today. A CTS-D engineer reviews your control approach, processor choice, and programming needs, usually within one business day.

Or call 1.888.230.3661 · Capability statement (PDF)
Creation Networks · Commercial AV integrator, nationwide since 2006.

Stay Updated!

Be the first to get exclusive deals, industry insights, and company updates!

RECENT POSTS
San Mateo Medical Center in San Mateo, California, a Creation Networks healthcare AV project

Multilingual Hospital Paging: Lobby, Wayfinding and Visiting-Hour Messages

Sky Lounge on Mubadala's 55th floor in Salesforce Tower, San Francisco, with a Chief cart-mounted display and PTZ camera

Audio Visual Consultant: What They Do and How to Vet One

Aerial view of Hyatt Regency Lake Tahoe Resort in Incline Village, Nevada, a Creation Networks hospitality audio project

Multilingual Announcements for Hotels, Resorts and Conference Centers

Extron IPCP Pro S1 xi control processor

Extron AV Switching and Control: A Spec Guide

Crestron CP4 4-Series control processor

Crestron Control Systems: CP4 vs CP4N vs DMPS Guide

Q-SYS paging station for recorded and live multilingual announcements

Multilingual Paging Systems: Recorded Announcements vs Live Translation for Venues