Contact a Creation Networks AV specialist
Product Questions? Ask Our Experts! 888.230.3661 sales@creationnetworks.net Contact us today for your best package pricing and product availability.

RDL RU2-CS1 – RS-232 Serial Control Interface

Regular price $715.75 Sale price $536.81
Shipping calculated at checkout.
✓ Ships from Stock
RDL  |  SKU: RU2-CS1

Ships in 24–48 hours on most in-stock orders

Best price or expert advice? Call 1-888-230-3661 or use Live Chat. Buying 1 or 100, you may qualify for greater savings.

Secure checkout We never store your card details.

Ach Direct DebitAmerican Express Apple Pay DiscoverGoogle Pay Mastercard USDC Visa

What is the RDL RU2-CS1?

The RDL RU2-CS1 is an RS-232 serial control interface that lets a computer or control system operate RDL modules and OEM equipment. It provides eight open-collector outputs, eight 0 to 10 Vdc control outputs and eight status inputs. Commands can come from a terminal program or from user software over a standard serial link. It suits boardrooms, training rooms and auditoriums where VCA levels and system functions need computer control.

How does it work?

RDL RU2-CS1 RS-232 serial controlled interface

Each of the eight open-collector outputs can be activated or deactivated by command, all outputs can be switched together, and a pulse command gives a 100 ms pulse. Active outputs are pulled to ground, which suits triggering RDL modules and OEM control inputs. The eight 0 to 10 Vdc outputs control external VCAs, with ramp rates preset individually or globally and levels that can ramp or jump to a new value. Each 0 to 10 Vdc output can also be programmed for 0 to 5 Vdc without loss of resolution, and the unit can report when a ramp completes. The status inputs sense external switch or transistor closures and can raise an alert on any change of state, or when a defined pattern of all eight inputs occurs. The controlling computer can query one or all status inputs at any time. An initialization command sets all parameters to known values, and optional error codes help during software development. Front-panel LEDs show active outputs, active status inputs, transmit and receive data, errors and power. RDL recommends the PS-24AS power supply for the USA or the PS-24AX for international installations; the supply is not included.

What are the key features?

  • RS-232 control — A computer or control system sends commands over a standard serial link.
  • Eight open-collector outputs — Outputs switch on, off or pulse to trigger RDL modules and OEM equipment.
  • Eight 0 to 10 Vdc outputs — Programmable ramping controls external VCA levels.
  • Eight status inputs — Switch or transistor closures can trigger alerts or be queried.
  • Front-panel indicators — LEDs show output, input, data, error and power status.

Where is it typically used?

  • Boardroom
  • Training room
  • Auditorium
  • Broadcast studio
  • Government space

Technical Specifications

Model RU2-CS1
Control Interface RS-232 serial
Open-Collector Outputs 8 (pulled to ground when active; 100 ms pulse command available)
Control Voltage Outputs 8 x 0 to 10 Vdc (programmable for 0 to 5 Vdc); individual or global ramp rates
Status Inputs 8 (sense external switch or transistor closures)
Front-Panel Indicators Active outputs, active status inputs, transmit and receive data, errors, power
Installation Free-standing or rack-mounted
Recommended Power Supply PS-24AS (USA), PS-24AX (International); not included

Frequently Asked Questions

What can the RU2-CS1 control?

It drives eight open-collector outputs and eight 0 to 10 Vdc outputs, which can control RDL VCA modules or other equipment with 0 to 10 Vdc control inputs.

Does it need special software?

No. Commands may be sent from a terminal program or from user software over the RS-232 link.

Can it report input changes?

Yes. It can alert the computer when any status input changes state, or when a defined pattern of all eight inputs occurs, and inputs can also be queried.

Is the power supply included?

No. RDL recommends the PS-24AS power supply for the USA or the PS-24AX for international installations; the supply is not included.

How is it installed?

RDL describes the RU2-CS1 as suitable for free-standing or rack-mounted installation.

What warranty does the RU2-CS1 carry?

This product is covered by a 7-year RDL warranty. For warranty claims, RMAs or support, contact Creation Networks at (888) 230-3661 or sales@creationnetworks.net.

Can Creation Networks help integrate the RU2-CS1?

Yes. Creation Networks supports system design, equipment selection and installation planning for RDL products nationwide. Call (888) 230-3661 for a quote or technical help.

NATIONWIDE AV SERVICES

Nationwide Audiovisual Services, Design, Installation & Support