Product Overview

The Middle Atlantic UPX-RLNK-1000R-8 is a NEXSYS 1000VA online rackmount UPS combining battery backup with a built-in RLNK (Remote Link) network-controlled PDU and 8 individually switched outlets. It is designed for AV integrators and IT managers who need both power protection and remote outlet-level control from a single 1U device. The RLNK interface enables IP-based outlet switching, load scheduling, and power sequencing without a separate PDU or network card.

Product Description

The UPX-RLNK-1000R-8 uses an online double-conversion topology, which means connected equipment always runs from the inverter regardless of utility power quality. This eliminates transfer time during outages and provides the highest level of isolation from power disturbances — important for sensitive digital audio and video processing equipment. The 1000VA / 900W capacity is suited for smaller AV racks, network closets, and broadcast sub-racks.

Each of the 8 outlets is individually addressable via the RLNK network interface, allowing operators to reboot hung devices, sequence power on startup, or shed non-critical loads remotely without dispatching a technician. The RLNK module also provides outlet-level current metering, so integrators can monitor individual device draw and receive email or SNMP alerts for overload conditions. A front-panel LCD display shows runtime estimate, load percentage, input voltage, and battery status at a glance.

The unit installs in a standard 19" rack and is compatible with Middle Atlantic rack enclosures. Replaceable battery cartridges support in-field battery swaps without removing the UPS from the rack. This product is available from Creation Networks with pre-sales consultation for rack power design.

Key Features

  • Online Double-Conversion Topology — Zero transfer time; equipment always runs from inverter for maximum isolation.
  • 1000VA / 900W Capacity — Sized for smaller AV racks, network closets, and broadcast sub-racks.
  • 8 Individually Switched Outlets — Per-outlet IP control for remote rebooting, load shedding, and power sequencing.
  • RLNK Network Interface — IP-based management with outlet-level current metering, SNMP, and email alerting.
  • Front-Panel LCD — Displays runtime, load %, input voltage, and battery status without a network connection.
  • Replaceable Battery Cartridges — In-rack battery swap without removing the unit from service.
  • 1U Rackmount — Minimal rack space footprint for space-constrained installations.

Typical Applications

  • AV control racks requiring outlet-level remote reboot capability
  • Network equipment closets where tech dispatch is impractical
  • Broadcast sub-racks with mixed critical and non-critical loads
  • IT server racks requiring per-outlet power monitoring and SNMP integration

Technical Specifications

Specification Value
Model UPX-RLNK-1000R-8
Series NEXSYS
Capacity 1000VA / 900W
Topology Online Double-Conversion
Outlet Count 8
Outlet Control Individual IP switching via RLNK
Network Interface RLNK (Ethernet, SNMP, email)
Form Factor 1U Rackmount, 19"
Battery Type Sealed, field-replaceable cartridge
Brand Middle Atlantic

Frequently Asked Questions

What does RLNK mean?
RLNK stands for Remote Link, Middle Atlantic's network-controlled PDU platform. It provides per-outlet IP switching, current metering, SNMP support, and email alerting from a web browser or network management system.
Is this a true online UPS or line-interactive?
The UPX-RLNK-1000R-8 uses online double-conversion topology. Equipment always runs from the inverter — there is no transfer delay during an outage, unlike line-interactive designs.
Can I control individual outlets if the network is down?
Outlet switching via the RLNK interface requires a network connection. Front-panel controls and display remain operational for local status monitoring regardless of network availability.
Where can I order this unit or get a pre-sales rack power consultation?
Contact Creation Networks for pricing, availability, and rack power design assistance.
NATIONWIDE AV SERVICES

Nationwide Audiovisual Services, Design, Installation & Support

Creation Networks is a trusted nationwide partner for complete audiovisual solutions — delivering expert AV system sales, professional design, programming, installation, and ongoing support to organizations across the United States.

From Microsoft Teams Rooms and enterprise video conferencing to LED video walls, live streaming production, and hybrid collaboration systems, we provide end-to-end AV integration using premium, certified technology from industry leaders including Crestron, Q-SYS, Shure, Extron, and Absen.

Whether you operate a single location or manage facilities nationwide, Creation Networks ensures your AV systems are designed for reliability, scalability, security, and long-term performance — helping your organization communicate more effectively and operate at peak efficiency.

CREATION NETWORKS — A PARTNER YOU CAN TRUST SINCE 2006