Eaton PDUMNH30AT2 – 2.9kW ATS/Monitored PDU, TAA
Eaton PDUMNH30AT2 – 2.9kW ATS/Monitored PDU, TAA is backordered and will ship as soon as it is back in stock.
Shipping Availability*
Shipping Availability*
Free Ground Shipping on Most Orders Over $250.00
Looking for the best price or expert advice? Give us a call at 1-888-230-3661 or use the Live Chat below. Buying 1 or 100, you may qualify for greater savings beyond the advertised price.
Product Overview
The Eaton PDUMNH30AT2 is a 2.9kW single-phase 30A ATS and monitored PDU built for network IT applications, small computer rooms, and equipment rack deployments that need both redundant power and real-time remote visibility. It combines 24 NEMA 5-15/20R outlets and one NEMA L5-30R outlet with dual L5-30P inputs, automatic transfer switching, and a built-in network interface for monitoring voltage, frequency, and load levels. TAA-compliant construction makes this monitored ATS PDU eligible for GSA Schedule and other federal procurement contracts, in addition to standard commercial data center and server room deployments.
Product Description
This 2U rack-mount PDU distributes network-grade power to rack equipment while providing real-time current metering, remote power monitoring, and automatic transfer switching in a single unit. Twenty-four NEMA 5-15/20R 120V outlets and one NEMA L5-30R outlet distribute AC power to a mix of standard rack devices and higher-draw equipment, while dual 10-foot (3.1-meter) power cords with NEMA L5-30P inputs connect to separate primary and secondary mains circuits, backup generators, UPS systems, or utility power grids — including out-of-phase sources. Dynamic solid-state automatic transfer switching (ATS) allows the PDU to switch to the secondary source within 1-5 milliseconds should the primary fail or become unstable, helping ensure connected equipment operates without interruption. An on-board ATS processor continuously evaluates the power quality of both input sources and prevents switching if the secondary source is unavailable or of lower quality than the primary. The built-in LX Platform network management card, branded WEBCARDLX, is HTML5-based and enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet, or SSH. Integrators can also use Tripp Lite's PowerAlert Device Manager (PADM20) for enhanced remote management, including customizable dashboard graphs, and PowerAlert Element Manager (PAEM) for expanding maintenance functions across large installations, including firmware update checks and configuration backup/restoration. A three-digit LED display shows measured or calculated amperage, kilowatt, and voltage values at a glance, with 1% billing-grade current monitoring accuracy to help maintain load levels well below maximum capacity and keep total cost of ownership low. The all-metal housing mounts into 2U of rack space using included hardware, or can be secured to a wall or under a counter, with cord retention brackets helping organize connected power cords. The unit's TAA compliance makes it eligible for GSA Schedule and other federal procurement contracts, in addition to standard commercial deployments.

Key Features
- 2.9kW ATS with Millisecond Failover — Solid-state automatic transfer switching moves to the secondary source in 1-5 milliseconds if the primary fails.
- 25-Outlet Capacity — 24 NEMA 5-15/20R outlets and one NEMA L5-30R outlet distribute power to a mix of standard and higher-draw equipment.
- Remote Voltage, Frequency, and Load Monitoring — The built-in WEBCARDLX network interface provides real-time remote monitoring with 1% billing-grade accuracy.
- Dual L5-30P Inputs — Two 10-foot cords connect to separate primary and secondary sources, including out-of-phase configurations.
- Three-Digit LED Display — Shows measured amperage, kilowatt, and voltage values at a glance for quick load checks.
- TAA-Compliant for Federal Procurement — Eligible for GSA Schedule and other federal contracts requiring Trade Agreements Act compliance.
- PowerAlert Device Manager Compatible — Supports PADM20 and PAEM for enhanced remote management across large installations.
Typical Applications
- Data center
- Server room
- Network closet
- Colocation facility
Technical Specifications
| Power Rating | 2.9kW |
| Input Voltage | 120V single-phase |
| Input Plug | Dual L5-30P |
| Input Cord Length | 10 ft. (3.1 m) each |
| Output Outlets | 24 x NEMA 5-15/20R, 1 x NEMA L5-30R |
| Form Factor | 2U rack-mount |
| Compliance | TAA compliant |
Frequently Asked Questions
What makes this PDU TAA-compliant, and why does that matter?
The PDUMNH30AT2 is compliant with the Trade Agreements Act, which makes it eligible for purchase under GSA Schedule and other federal procurement contracts.
How quickly does the ATS switch to the secondary power source?
Dynamic solid-state switching transfers the load to the secondary source within 1-5 milliseconds if the primary source fails or becomes unstable.
Can the two input cords connect to out-of-phase power sources?
Yes, the dual L5-30P inputs support separate primary and secondary mains circuits, generators, UPS systems, or utility grids, including out-of-phase sources.
How accurate is the current monitoring?
The unit provides 1% billing-grade accuracy for current monitoring, in addition to voltage and frequency data.
What management software works with this PDU?
It's compatible with Tripp Lite's PowerAlert Device Manager (PADM20) and PowerAlert Element Manager (PAEM) for enhanced remote management, firmware update checks, and configuration backup/restoration.
Does this PDU need to be rack-mounted, or can it be installed elsewhere?
It mounts into 2U of standard EIA-19-inch rack space using the included hardware, or can be secured to a wall or under a counter.
What warranty applies to the PDUMNH30AT2?
Eaton backs this unit with its standard manufacturer warranty; contact Creation Networks for the current term and any extended coverage options.
Can Creation Networks assist with a federal procurement purchase of this PDU?
Yes, our team can support GSA Schedule and other federal procurement purchases given the unit's TAA compliance.
At Creartion Networks, we do everything we can to create an excellent customer experience. This includes fast shipping and easy returns.
- Most in-stock orders placed Monday-Friday ship within 24-48 hours. General restrictions apply; please see our full shipping policy here.
- We offer a 30-day return policy from the delivery date on many products. Product restrictions apply. Restocking fees for the return of open-box items. Please see our full return policy here for more information.
Nationwide Audiovisual Services, Design, Installation & Support
Creation Networks is a trusted nationwide partner for complete audiovisual solutions — delivering expert AV system sales, professional design, programming, installation, and ongoing support to organizations across the United States.
From Microsoft Teams Rooms and enterprise video conferencing to LED video walls, live streaming production, and hybrid collaboration systems, we provide end-to-end AV integration using premium, certified technology from industry leaders including Crestron, Q-SYS, Shure, Extron, and Absen.
Whether you operate a single location or manage facilities nationwide, Creation Networks ensures your AV systems are designed for reliability, scalability, security, and long-term performance — helping your organization communicate more effectively and operate at peak efficiency.
CREATION NETWORKS — A PARTNER YOU CAN TRUST SINCE 2006