The Eaton PDUMNH30 is a compact 2U metered rack PDU designed for single-phase 120V server rooms and network closets that need reliable power distribution without the cost of a fully managed unit. This horizontal rack-mount PDU uses an L5-30P input plug and provides 16 output receptacles, making it a practical metered PDU choice for mid-size IT racks. Its LX interface delivers input current and voltage readings so administrators can monitor load and avoid tripped breakers. IT integrators specifying a 120V metered PDU for standard equipment cabinets will find this model easy to install in just 2U of rack space.
Product Description
Unlike 0U vertical PDUs, the PDUMNH30 mounts horizontally and occupies 2U of standard rack space, which suits smaller cabinets or environments where vertical rail space is already committed to cable management or other 0U devices. It accepts a single-phase 120V, 24A feed through an L5-30P plug and distributes power across 16 outlets, giving room for servers, switches, KVM units, and other rack-mounted IT gear. The built-in metering reports real-time input voltage and current draw through the LX interface, giving facilities staff a way to confirm the circuit isn't approaching its 2.9kW capacity before adding more equipment. A 10 ft. input cord is included, giving installers flexibility when the source receptacle isn't directly adjacent to the rack. This PDU is a good fit for network closets, small server rooms, and secondary/backup racks where metered rather than switched or per-outlet managed monitoring is sufficient.

Key Features
- 2.9kW Single-Phase Capacity — Sized for standard 120V circuits common in server rooms and network closets.
- 16 Output Receptacles — Provides ample outlet count for a mid-size rack of servers and networking equipment.
- 2U Horizontal Form Factor — Mounts in standard rack rails without requiring 0U vertical space.
- L5-30P Input Plug — Matches common 30A single-phase receptacles used in commercial IT installations.
- Metered Input Monitoring — Reports real-time voltage and current via the LX interface for load management.
- 10 ft. Input Cord — Offers flexibility for connecting to wall or floor-mounted receptacles.
Typical Applications
- Server room
- Network closet
- Data center
Technical Specifications
| Spec | Value |
|---|---|
| Power Rating | 2.9 kW |
| Input Voltage | 120V, single-phase |
| Input Current | 24A |
| Input Plug | NEMA L5-30P |
| Input Cord Length | 10 ft. |
| Output Receptacles | 16x 5-20R |
| Form Factor | 2U, horizontal |
| Monitoring | Metered (input-level) with LX interface |
| Dimensions | 17.5 in W x 3.5 in H x 12.5 in D |
| Weight | 13.8 lb |
Frequently Asked Questions
How much rack space does the PDUMNH30 require?
It mounts horizontally in 2U of standard 19-inch rack space, leaving 0U vertical rails free for other devices or cable management.
Does this PDU support remote outlet switching?
No. The PDUMNH30 is a metered PDU that reports input-level voltage and current through the LX interface; it does not provide per-outlet switching.
What circuit does the PDUMNH30 require?
A dedicated single-phase 120V circuit rated at 24A, terminated with a NEMA L5-30P plug.
How many devices can connect to this PDU?
It provides 16 output receptacles, supporting up to 16 individually connected devices within the 2.9kW capacity limit.
Is this PDU suitable for a network closet installation?
Yes. Its compact 2U form factor and metered monitoring make it a practical fit for network closets and small server rooms.
What warranty does Eaton provide on this PDU?
Eaton backs this unit with its standard manufacturer warranty; contact Creation Networks for the current term and any extended coverage options.
At Creartion Networks, we do everything we can to create an excellent customer experience. This includes fast shipping and easy returns.
- Most in-stock orders placed Monday-Friday ship within 24-48 hours. General restrictions apply; please see our full shipping policy here.
- We offer a 30-day return policy from the delivery date on many products. Product restrictions apply. Restocking fees for the return of open-box items. Please see our full return policy here for more information.
Nationwide Audiovisual Services, Design, Installation & Support
Creation Networks is a trusted nationwide partner for complete audiovisual solutions — delivering expert AV system sales, professional design, programming, installation, and ongoing support to organizations across the United States.
From Microsoft Teams Rooms and enterprise video conferencing to LED video walls, live streaming production, and hybrid collaboration systems, we provide end-to-end AV integration using premium, certified technology from industry leaders including Crestron, Q-SYS, Shure, Extron, and Absen.
Whether you operate a single location or manage facilities nationwide, Creation Networks ensures your AV systems are designed for reliability, scalability, security, and long-term performance — helping your organization communicate more effectively and operate at peak efficiency.
CREATION NETWORKS — A PARTNER YOU CAN TRUST SINCE 2006