Eaton PDU3EVSR1G60 – 3-Phase IsoBreaker Managed PDU

Regular price $4,101.00 Sale price $2,916.10
Shipping calculated at checkout.
Eaton  |  SKU: PDU3EVSR1G60

Shipping Availability*

Free Ground Shipping on Most Orders Over $250.00

Looking for the best price or expert advice? Give us a call at 1-888-230-3661 or use the Live Chat below. Buying 1 or 100, you may qualify for greater savings beyond the advertised price.

Accepted payment methods

Product Overview

The Eaton PDU3EVSR1G60 is a 3-phase managed rack PDU built for data center and server room deployments that need per-outlet power monitoring and fault isolation. As a 0U vertical rack PDU, it mounts along the side rail of a server cabinet, delivering 12.6kW of switched, outlet-level power distribution without consuming valuable U space. This managed rack PDU is a strong fit for colocation providers and enterprise IT rooms building out equipment racks that require remote power control and IsoBreaker circuit protection.

Product Description

The PDU3EVSR1G60 belongs to Eaton's IsoBreaker managed PDU line, engineered so a single overloaded outlet trips its own isolated breaker instead of taking down the entire strip. That design detail matters in dense racks where one misbehaving device shouldn't cause a cascading outage across a shared circuit. The unit accepts a 200-240V three-phase input through a 60A IEC-60309 (460P9W) plug on a 10 ft cord, and distributes power across 36 outlets (30x C13, 6x C19) for a total capacity of 12.6kW.

Reference the product photo for the physical outlet layout and color-coded IsoBreaker indicators along the 70-inch vertical chassis. A built-in color touchscreen LCD displays real-time current draw, environmental readings, and network status directly on the unit, which speeds up rack-level troubleshooting without needing to pull up a management console. The Gigabit-capable network interface supports remote monitoring and outlet switching, letting facilities and IT staff cycle power to individual devices from outside the room.

Integrators specifying this PDU for a new server room build-out should confirm rack rail compatibility and available IEC-60309 receptacle capacity at the source panel before ordering, since the 60A three-phase input requires appropriately rated upstream infrastructure. Operating range is rated 0-60°C, making it suitable for standard data center and telecom environments.

Eaton PDU3EVSR1G60 – 3-Phase IsoBreaker Managed PDU

Key Features

  • IsoBreaker Outlet Protection — Isolates and trips only the affected outlet during an overload, keeping the rest of the PDU's outlets live.
  • 3-Phase 12.6kW Capacity — Supports dense rack power loads from a single 60A three-phase input.
  • 36 Total Outlets — 30x C13 and 6x C19 receptacles cover mixed server and network equipment power cords.
  • Color Touchscreen LCD — Displays live current, environmental data, and network status at the rack.
  • Gigabit Network Management — Enables remote monitoring and individual outlet switching over Ethernet.
  • 0U Vertical Form Factor — Mounts in the rack's side channel, preserving usable U space for equipment.

Typical Applications

  • Data center
  • Colocation facility
  • Server room
  • Network closet

Technical Specifications

Spec Value
Input Voltage 200-240V, three-phase
Input Current 35A (rated); 60A IEC-60309 plug
Input Plug IEC-60309 60A Blue, 3P+E (460P9W)
Cord Length 10 ft
Output Capacity 12.6kW
Outlets 36 total: 30x C13, 6x C19
Form Factor 0U, vertical rack-mount
Dimensions (H x W x D) 70 in x 2.17 in x 3.11 in
Weight 21.38 lb
Management Gigabit network module, color touchscreen LCD, SNMP
Operating Temperature 0-60°C (32-140°F)
Compliance TAA, RoHS, FCC Class A; CSA, UL 62368-1

Frequently Asked Questions

What does IsoBreaker protection do on this PDU?

It isolates an overloaded outlet to its own breaker so a single fault trips only that outlet, rather than taking the entire PDU strip offline.

What circuit is required to install the PDU3EVSR1G60?

A 200-240V three-phase circuit terminated in an IEC-60309 60A (460P9W) receptacle, matched to the unit's 10 ft input cord.

Can this PDU integrate with a network operations center's monitoring tools?

Yes. The Gigabit-capable network interface with SNMP support allows remote monitoring and individual outlet switching from outside the room.

Is this rack PDU suitable for colocation deployments?

Yes. Its 0U vertical mounting, IsoBreaker fault isolation, and remote outlet control are well suited to colocation and enterprise IT room installations.

What certifications does this PDU carry?

It carries TAA, RoHS, FCC Class A, CSA, and UL 62368-1 compliance.

What warranty applies to the PDU3EVSR1G60?

Eaton backs this unit with its standard manufacturer warranty; contact Creation Networks for the current term and any extended coverage options.

NATIONWIDE AV SERVICES

Nationwide Audiovisual Services, Design, Installation & Support

Creation Networks is a trusted nationwide partner for complete audiovisual solutions — delivering expert AV system sales, professional design, programming, installation, and ongoing support to organizations across the United States.

From Microsoft Teams Rooms and enterprise video conferencing to LED video walls, live streaming production, and hybrid collaboration systems, we provide end-to-end AV integration using premium, certified technology from industry leaders including Crestron, Q-SYS, Shure, Extron, and Absen.

Whether you operate a single location or manage facilities nationwide, Creation Networks ensures your AV systems are designed for reliability, scalability, security, and long-term performance — helping your organization communicate more effectively and operate at peak efficiency.

CREATION NETWORKS — A PARTNER YOU CAN TRUST SINCE 2006