Product Questions? Ask Our Experts! 888.230.3661 sales@creationnetworks.net Contact us today for your best package pricing and product availability.

Eaton EMAGKEC4C4C4C4L – 3-Phase 36kW Managed HDX Rack PDU

Regular price $5,671.00 Sale price $3,687.20
Shipping calculated at checkout.
Eaton  |  SKU: EMAGKEC4C4C4C4L

Shipping Availability*

Free Ground Shipping on Most Orders Over $250.00

Looking for the best price or expert advice? Give us a call at 1-888-230-3661 or use the Live Chat below. Buying 1 or 100, you may qualify for greater savings beyond the advertised price.

Accepted payment methods

Product Overview

The Eaton EMAGKEC4C4C4C4L is a 3-phase managed rack PDU delivering 36kW at 208V and 100A through 24 C39 combo outlets, purpose-built for high-density enterprise data center and colocation rack power. It is designed for GPU-intensive workloads such as HPC, supercomputing, generative AI, and high-frequency trading that demand extremely high power density per rack. As with other HDX Rack PDU G4 models, it uses hardwired input and 0U vertical mounting for permanent installation in dense compute racks. Integrators building out 208V 3-phase power infrastructure for AI or HPC deployments will find this model's outlet flexibility and TAA compliance well suited to enterprise and government procurement alike.

Product Description

The EMAGKEC4C4C4C4L HDX Rack PDU G4 is built for deployment within a rack in an enterprise data center, colocation data center, or distributed IT infrastructure environment. Equipped to meet diverse data center rack power needs, it delivers versatile, enterprise-quality power distribution for GPU-intensive applications like HPC, supercomputing, generative AI, and high-frequency trading that require extremely high power density. Rated 208V 3-phase at 100A, the unit provides up to 36kW of capacity through 24 C39 combo outlets, each of which accepts both C14 and C20 connectors, adding flexibility to deployments and reducing the number of distinct PDU types an integrator needs to stock. As a hardwired, 0U vertical rack PDU, it is intended for permanent installation by a qualified electrician, preserving usable rack space for compute, storage, and network equipment. The managed platform gives operations teams visibility into rack-level power consumption, which supports capacity planning in high-density GPU and HPC racks. This model is TAA-compliant, supporting government and GSA Schedule procurement requirements alongside standard commercial data center deployments.

Eaton EMAGKEC4C4C4C4L 3-phase managed HDX rack PDU G4, 208V

Key Features

  • 24 C39 Combo Outlets — Each outlet accepts both C14 and C20 connectors, reducing the number of PDU variants needed for mixed equipment loads.
  • 36kW at 208V, 100A — High-density 3-phase capacity supports GPU-intensive HPC and AI compute racks.
  • 0U Vertical Mounting — Occupies no usable rack units, preserving space for compute and network equipment.
  • Hardwired Input — Supports permanent installation on high-amperage 3-phase circuits typical of enterprise data centers.
  • Managed Monitoring — Provides rack-level power visibility for facilities and IT teams managing dense compute deployments.
  • TAA Compliance — Meets Trade Agreements Act requirements for government and GSA Schedule data center procurement.

Typical Applications

  • Enterprise data center
  • Colocation data center
  • High-performance computing (HPC) facility

Technical Specifications

Voltage 208V
Current Rating 100A
Power Capacity 36kW
Outlets 24 x C39 combo (accepts C14/C20)
Input Connection Hardwired
Form Factor 0U vertical
PDU Type 3-phase managed

Frequently Asked Questions

What is the power capacity of the EMAGKEC4C4C4C4L?

It delivers up to 36kW at 208V 3-phase and 100A, suited to high-density GPU and HPC rack loads.

What connectors does this PDU support?

The 24 C39 combo outlets each accept both C14 and C20 power cords, allowing one PDU to serve mixed equipment types.

Does installation require an electrician?

Yes, because the input is hardwired and rated for 208V 3-phase at 100A, installation should be performed by a qualified electrician per local code.

Is this PDU appropriate for GPU or AI compute racks?

Yes, its high power density and outlet flexibility make it well suited for GPU-intensive HPC, supercomputing, and generative AI deployments.

Can this PDU integrate with data center monitoring systems?

As a managed PDU, it is designed to support integration with DCIM and remote monitoring workflows; contact Creation Networks for specifics on your monitoring platform.

Is this model eligible for government procurement?

Yes, the EMAGKEC4C4C4C4L is TAA-compliant, making it eligible for GSA Schedule purchases.

What warranty does Eaton provide?

Eaton backs this unit with its standard manufacturer warranty; contact Creation Networks for the current term and any extended coverage options.

NATIONWIDE AV SERVICES

Nationwide Audiovisual Services, Design, Installation & Support

Creation Networks is a trusted nationwide partner for complete audiovisual solutions — delivering expert AV system sales, professional design, programming, installation, and ongoing support to organizations across the United States.

From Microsoft Teams Rooms and enterprise video conferencing to LED video walls, live streaming production, and hybrid collaboration systems, we provide end-to-end AV integration using premium, certified technology from industry leaders including Crestron, Q-SYS, Shure, Extron, and Absen.

Whether you operate a single location or manage facilities nationwide, Creation Networks ensures your AV systems are designed for reliability, scalability, security, and long-term performance — helping your organization communicate more effectively and operate at peak efficiency.

CREATION NETWORKS — A PARTNER YOU CAN TRUST SINCE 2006