Eaton EMIU29-06 – 3-Phase Metered Input Rack PDU, 2U
Eaton EMIU29-06 – 3-Phase Metered Input Rack PDU, 2U is backordered and will ship as soon as it is back in stock.
Shipping Availability*
Shipping Availability*
Free Ground Shipping on Most Orders Over $250.00
Looking for the best price or expert advice? Give us a call at 1-888-230-3661 or use the Live Chat below. Buying 1 or 100, you may qualify for greater savings beyond the advertised price.
Product Overview
The Eaton EMIU29-06 is a 3-phase metered input rack PDU built to feed downstream power equipment in data centers and server rooms running high-amperage 3-phase circuits. Housed in a 2U rack-mount chassis, it accepts a 240V/48A IEC 60309 input and steps down to six L6-30P locking outlets, a configuration suited to feeding secondary PDUs or clusters of high-draw rack gear. Input metering gives IT and facilities teams a read on total power draw across the 3-phase feed without the added cost of per-outlet monitoring. For data center power distribution designs that need an upstream 3-phase feed point rather than device-level outlets, this rack PDU fills that role.
Product Description
The EMIU29-06 occupies 2U of horizontal rack space and is built around a 3-phase IEC 60309 460P9W input connector on a 6 ft cord, terminating in six L6-30P locking outlets. This outlet configuration is typically used to feed secondary rack PDUs, UPS distribution panels, or clusters of high-draw equipment rather than individual servers directly, a common pattern in data center power distribution architecture.
Input metering lets facilities and IT teams track overall power draw across the 3-phase feed, supporting capacity planning in server rooms and data center pods where circuit loading has to be closely managed. Because the outlets are L6-30P locking receptacles, this rack PDU is generally deployed as an upstream distribution point in a rack or pod rather than as a general-purpose outlet strip for individual IT devices.
The 2U horizontal form factor makes installation straightforward in standard 19-inch racks and cabinets alongside existing power infrastructure. As with other metered-input rack PDUs, this model reports load data without offering per-outlet switching, which keeps it a cost-effective option for installations focused on monitoring circuit draw rather than remote outlet control.

Key Features
- 3-Phase Metered Input — Reports power draw across the full 3-phase 240V/48A input feed for data center capacity planning.
- 6 L6-30P Locking Outlets — Sized for feeding downstream PDUs, distribution panels, or clusters of high-draw rack equipment.
- IEC 60309 460P9W Input Connector — Industrial-grade 3-phase input connector suited to data center power infrastructure.
- 2U Rack-Mount Form Factor — Installs into standard 19-inch racks alongside other power distribution gear.
- 6 ft Input Cord — Provides flexible routing to nearby 3-phase receptacles.
- Commercial-Grade 3-Phase Distribution — Built for data center and server room environments running heavier 3-phase loads.
Technical Specifications
| Spec | Value |
|---|---|
| Input Voltage | 240V, 3-phase |
| Input Current | 48A |
| Input Connector | IEC 60309 460P9W |
| Cord Length | 6 ft |
| Outlets | 6x NEMA L6-30P |
| Form Factor | 2U, rack-mount |
| Monitoring | Metered input |
At Creartion Networks, we do everything we can to create an excellent customer experience. This includes fast shipping and easy returns.
- Most in-stock orders placed Monday-Friday ship within 24-48 hours. General restrictions apply; please see our full shipping policy here.
- We offer a 30-day return policy from the delivery date on many products. Product restrictions apply. Restocking fees for the return of open-box items. Please see our full return policy here for more information.
Nationwide Audiovisual Services, Design, Installation & Support
Creation Networks is a trusted nationwide partner for complete audiovisual solutions — delivering expert AV system sales, professional design, programming, installation, and ongoing support to organizations across the United States.
From Microsoft Teams Rooms and enterprise video conferencing to LED video walls, live streaming production, and hybrid collaboration systems, we provide end-to-end AV integration using premium, certified technology from industry leaders including Crestron, Q-SYS, Shure, Extron, and Absen.
Whether you operate a single location or manage facilities nationwide, Creation Networks ensures your AV systems are designed for reliability, scalability, security, and long-term performance — helping your organization communicate more effectively and operate at peak efficiency.
CREATION NETWORKS — A PARTNER YOU CAN TRUST SINCE 2006