SURGEX SX-DS-154

Safeguard Digital Displays Digital displays are a vital part of a business’s interaction with their customers. Power disturbances on video, data, and audio lines can result in pixilation, hissing/crackling sounds and error codes that render equipment inoperable—resulting in customer dissatisfaction and lost income.
  • Compact Design
  • Wiring fault protection
  • 4 receptacle configurations
  • 6’ line cord
  • Mounting brackets
The MultiPak safeguards digital equipment from surges, spikes, and electrical transients that can bring business to a halt. Its 360 degrees of power protection encompass multi-stage technology, catastrophic over/under voltage shutdown, inrush current elimination, and impedance tolerant noise filtering to ensure equipment remains up and running without disruption. The MultiPak’s analytical software monitors, collects and analyzes electrical data, allowing service teams to understand power anomalies. The software identifies the potential cause of a problem and translates that data into recommendations on how to resolve the issue.

Available in four and six receptacle configurations, the MultiPak is the clear choice to safeguard digital displays

Specifications

Parameter Specification
Load Rating 15A
Voltage Rating 120V
Power Requirement (no load) 4 W
EMI/RFI Filter
Normal mode (50Ω load) >30 dB, 80 kHz - 50 MHz
Common Mode (50Ω load) >30 dB 70 kHz - 50MHz
Under-Voltage Auto Shutdown Adjustable from 80V to 95V, or disabled. Default Disabled
Over-Voltage Auto Shutdown Adjustable from 135V to 160V. Default 150V.
Over-Current Auto Shutdown Circuit Breaker
Over-Temperature Auto Shutdown None
Measurement Accuracy
Voltage ± 2% Typical product accuracy between 40V and 180V
Current NA
Power NA
Energy NA
Temperature NA
Network Port No
Serial Port Custom Serial UART
Temperature Sensor Input None
Auxiliary Relay Outputs No
Contact Closure Input No
Dimensions 8.152" W x 7.272" D x 1.79" H
Weight 4.1 lbs
Temperature Range: 5C to 35C
Humidity Range 5% to 95% R.H. Non-condensing
Agency Listings Conforms to UL Stds 1283 & 1449; Certified to CSA Std C22.2 No. 8