{"product_id":"toa-vx-3008famq-vx-3000-main-frame-up-to-3-vx-series-amplifiers-8-zones-switching-between-2-amps-standby-amp","title":"TOA VX-3008F AMQ 8-Zone Voice Evacuation System Frame","description":"\u003cp dir=\"auto\"\u003eThe TOA VX-3008F AMQ is a compact 3U rack-mount frame unit from the VX-3000 Series, designed for EN54-compliant voice alarm systems, managing emergency announcements with advanced DSP processing and up to 8 speaker zones when equipped with optional power amplifier modules.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eIt features comprehensive digital signal processing including parametric equalization, filtering, compression, delay, feedback suppression with dynamic filters, VOX for audio-triggered broadcasts, and ambient noise control that distinguishes system output from background noise for automatic level adjustment.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThis frame supports matrix configurations for flexible zone routing, shared standby amplifiers across units, redundant network links for fault tolerance, and simultaneous dual emergency broadcast patterns, making it suitable for scalable installations in public buildings, offices, hotels, schools, hospitals, auditoriums, transportation hubs, and commercial facilities requiring certified, reliable voice evacuation.\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv dir=\"auto\"\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ctable dir=\"auto\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth data-col-size=\"md\"\u003eFeature\u003c\/th\u003e\n\u003cth data-col-size=\"lg\"\u003eBenefit\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eEN54-16 Compliance\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eEnsures certified reliability for fire alarm voice evacuation in European-standard systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003e8 Speaker Zones\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eEnables precise zoning for targeted emergency messaging in medium-sized facilities\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eUp to 3 Amplifier Modules (2 zone + 1 standby)\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eProvides flexible power setup with shared redundancy for high availability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eAdvanced DSP Processing\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eOffers per-channel EQ, compressor, delay, and filters for optimized audio clarity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eFeedback Suppressor\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eAutomatically eliminates howling with 7 dynamic filters for stable live microphone use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eAmbient Noise Control (ANC)\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eAutomatically adjusts volume based on real ambient noise without false triggers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eVOX Audio Trigger\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eInitiates broadcasts hands-free via detected sound for quick response\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eRedundant Network Links\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eSupports LAN\/RS\/Analog redundancy for distributed, fault-tolerant large-scale systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv dir=\"auto\"\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ctable dir=\"auto\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth data-col-size=\"md\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-col-size=\"lg\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003ePower Source\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e20-33 V DC (via power supply unit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e24 W (frame only); up to 90 W with RS Link\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eSpeaker Zones\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e8 channels (100 V RMS, 5 A RMS max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eModule Slots\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e3 (for DA-015\/030\/050 series amplifiers)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eAudio Inputs\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e4 local (MIC\/LINE\/ANC selectable, phantom power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eControl Inputs\/Outputs\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e16 general + emergency; 8 general + 3 exclusive outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eNetwork\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e2 x RJ45 (LAN A\/B, 100BASE-TX); RS Link A\/B; DS Link; Analog Link\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eDSP Functions\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eParametric\/shelving\/notch\/all-pass EQ, compressor, delay (up to 2.73 s), FBS, ANC, VOX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eFault Detection\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eSpeaker line (short\/open\/ground), control inputs, power, CPU, network\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e483 × 132.6 × 345 mm (19\" × 5.22\" × 13.58\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e7.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eFinish\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eBlack surface-treated steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e-5 °C to +45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv dir=\"auto\"\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ctable dir=\"auto\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth data-col-size=\"lg\"\u003eAspect\u003c\/th\u003e\n\u003cth data-col-size=\"lg\"\u003eTOA VX-3008F AMQ\u003c\/th\u003e\n\u003cth data-col-size=\"md\"\u003eTOA VX-3016F AMQ\u003c\/th\u003e\n\u003cth data-col-size=\"md\"\u003eBosch Plena VAS\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"lg\"\u003eZones\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e8\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003e16\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003eUp to 12 (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"lg\"\u003eAmplifier Modules\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eUp to 3 (2 zone + 1 standby)\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003eUp to 2\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003eIntegrated\/external\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"lg\"\u003eDSP Features\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eFBS, ANC, VOX, delay, advanced EQ\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003eFBS, ANC, VOX, delay, advanced EQ\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003eBasic EQ, supervision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"lg\"\u003eNetwork Redundancy\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eLAN\/RS\/Analog links\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003eLAN\/RS\/Analog links\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003eRouter-based\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"lg\"\u003eStandby Amp Sharing\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eYes\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"lg\"\u003eRack Size\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e3U\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003e3U\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003eVaries (2-6U)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"lg\"\u003eSimultaneous Emergencies\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eDual patterns\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003eDual patterns\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003eSingle\/multiple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"lg\"\u003eFault Monitoring\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eComprehensive per line\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003eComprehensive per line\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003eLine supervision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp dir=\"auto\"\u003eFAQ\u003c\/p\u003e\n\u003cul dir=\"auto\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat certification does the VX-3008F AMQ hold?\u003c\/strong\u003e It is fully compliant with EN54-16 for voice alarm control and indicating equipment in fire detection systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many zones does it support?\u003c\/strong\u003e Up to 8 speaker zones, configurable with matrix routing and optional amplifier modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat amplifier modules are compatible?\u003c\/strong\u003e VX-015DA (150W), VX-030DA (300W), or VX-050DA (500W) Class D digital modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes it support distributed networking?\u003c\/strong\u003e Yes, with redundant LAN\/RS\/Analog links for connecting multiple frames up to 800m apart.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat fault detection is included?\u003c\/strong\u003e Monitors speaker lines for short\/open\/ground faults, plus inputs, power, CPU, and network status.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"TOA","offers":[{"title":"Default Title","offer_id":46740518961388,"sku":"VX-3008F    AMQ","price":3655.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/CN_VX-3008FAMQ.jpg?v=1775826893","url":"https:\/\/creationnetworks.net\/products\/toa-vx-3008famq-vx-3000-main-frame-up-to-3-vx-series-amplifiers-8-zones-switching-between-2-amps-standby-amp","provider":"Creation Networks","version":"1.0","type":"link"}