{"product_id":"toa-vx-3004famq-vx-3000-main-frame-up-to-4-vx-series-amplifiers-1-zone-1-amp","title":"TOA VX-3004F AMQ EN54 Voice Evacuation Frame with 4 Zones","description":"\u003cp dir=\"auto\"\u003eThe TOA VX-3004F AMQ is a compact 3U rack-mount frame unit from the VX-3000 Series, engineered for EN54-compliant voice alarm systems, managing emergency announcements with sophisticated DSP processing and up to 4 speaker zones (with A\/B lines) when fitted with optional power amplifier modules.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eIt incorporates extensive digital signal processing capabilities, including parametric equalization, high\/low-pass filters, compression, delay, a feedback suppressor with 7 dynamic filters, VOX for sound-activated broadcasting, and ambient noise control that intelligently differentiates system output from background noise to adjust volumes automatically.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThis versatile frame enables matrix routing for precise zone selection, shared standby amplifiers across multiple units, redundant network connections for high reliability, and simultaneous dual-pattern emergency broadcasts, making it ideal for small to medium-scale installations in public buildings, offices, hotels, schools, hospitals, auditoriums, transportation facilities, and commercial spaces requiring certified, intelligent voice evacuation solutions.\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv dir=\"auto\"\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ctable dir=\"auto\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth data-col-size=\"md\"\u003eFeature\u003c\/th\u003e\n\u003cth data-col-size=\"lg\"\u003eBenefit\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eEN54-16 Compliance\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eGuarantees certified performance for fire alarm voice evacuation in regulated environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003e4 Speaker Zones (A\/B Lines)\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eDelivers duplicated lines for fault-tolerant, targeted emergency messaging in smaller facilities\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eUp to 4 Amplifier Modules\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eSupports configurations like 4 zones or 3 zones + shared standby for redundancy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eAdvanced DSP Processing\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eProvides tailored EQ, compression, delay, and filters per input\/output for superior audio clarity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eFeedback Suppressor\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eDynamically prevents acoustic feedback with 7 auto filters for stable microphone operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eAmbient Noise Control (ANC)\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eAdapts broadcast volume to real ambient levels without self-detection interference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eVOX Audio Trigger\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eEnables automatic, hands-free activation of announcements via detected sound\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eRedundant Network Links\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eEnsures system continuity with LAN\/RS\/Analog backup for distributed setups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv dir=\"auto\"\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ctable dir=\"auto\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth data-col-size=\"md\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-col-size=\"lg\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003ePower Source\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e20-33 V DC (via external power supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e24 W (frame only); up to 90 W with RS Link\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eSpeaker Zones\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e4 channels (100 V RMS, 5 A RMS max, A\/B lines)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eModule Slots\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e4 (for DA-015\/030\/050 series amplifiers)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eAudio Inputs\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e4 local (MIC\/LINE\/ANC selectable, phantom power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eControl Inputs\/Outputs\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e16 general + emergency inputs; 8 general + 3 exclusive outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eNetwork\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e2 x RJ45 (LAN A\/B, 100BASE-TX); RS Link A\/B; DS Link; Analog Link\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eDSP Functions\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eParametric EQ, compressor, delay (up to 2.73 s), FBS (7 filters), ANC, VOX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eFault Detection\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eSpeaker line (short\/open\/ground), controls, power, CPU, network\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e483 × 132.6 × 345 mm (19\" × 5.22\" × 13.58\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e7.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eFinish\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eBlack surface-treated steel panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e-5 °C to +45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv dir=\"auto\"\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ctable dir=\"auto\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth data-col-size=\"md\"\u003eAspect\u003c\/th\u003e\n\u003cth data-col-size=\"lg\"\u003eTOA VX-3004F AMQ\u003c\/th\u003e\n\u003cth data-col-size=\"md\"\u003eTOA VX-3008F AMQ\u003c\/th\u003e\n\u003cth data-col-size=\"md\"\u003eTOA VX-3016F AMQ\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eZones\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e4 (with A\/B lines)\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003e8 (with A\/B lines)\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003e16 (with A\/B lines)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eAmplifier Module Slots\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eUp to 4\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003eUp to 3\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003eUp to 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eTypical Configurations\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e4 zones or 3 + standby\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003e8 zones or with standby sharing\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003e16 zones or with standby\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eStandby Amp Sharing\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eYes (across units)\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eRack Size\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e3U\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003e3U\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003e3U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eDSP Features\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eFull (FBS, ANC, VOX, advanced EQ)\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003eFull\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003eFull\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eNetwork Redundancy\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eLAN\/RS\/Analog\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003eLAN\/RS\/Analog\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003eLAN\/RS\/Analog\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e7.6 kg\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003e7.9 kg\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003e8.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp dir=\"auto\"\u003eFAQ\u003c\/p\u003e\n\u003cul dir=\"auto\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat certification does the VX-3004F AMQ hold?\u003c\/strong\u003e It is fully compliant with EN54-16 for voice alarm control and indicating equipment in fire detection systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many zones does it support?\u003c\/strong\u003e Up to 4 speaker zones with duplicated A\/B lines for redundancy, configurable via matrix routing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat amplifier modules are compatible?\u003c\/strong\u003e Optional Class D modules: VX-015DA (150W), VX-030DA (300W), or VX-050DA (500W).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan standby amplifiers be shared?\u003c\/strong\u003e Yes, via dedicated input\/output terminals for sharing across multiple VX-3000 frames.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat network options are available?\u003c\/strong\u003e Redundant LAN, RS Link, and Analog Link for distributed systems up to 800m apart with fault tolerance.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"TOA","offers":[{"title":"Default Title","offer_id":46740518863084,"sku":"VX-3004F    AMQ","price":3460.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/CN_VX-3004FAMQ.jpg?v=1775826882","url":"https:\/\/creationnetworks.net\/products\/toa-vx-3004famq-vx-3000-main-frame-up-to-4-vx-series-amplifiers-1-zone-1-amp","provider":"Creation Networks","version":"1.0","type":"link"}