{"product_id":"toa-vm-3240eamq-vm-extension-amplifier-240w-ul-2572-864","title":"TOA VM-3240E AMQ 240W Extension Amplifier for VM-3000 Series","description":"\u003cp dir=\"auto\"\u003eThe TOA VM-3240E AMQ is a microprocessor-controlled extension amplifier that adds 240W of power and up to 6 additional speaker zones to the VM-3000 Series voice evacuation system, maintaining full compliance and monitoring capabilities.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eConstructed in a durable black surface-treated steel case with aluminum front panel for 3U rack mounting, it features continuous speaker line monitoring, local audio input, and general\/control interfaces for expanded functionality in larger installations.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eIdeal for extending coverage in schools, offices, hotels, hospitals, airports, retail stores, houses of worship, sports facilities, and commercial buildings, it connects seamlessly to the VM-3240VA AMQ master unit via RJ45 VM Link for integrated emergency broadcasts, paging, and BGM.\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv dir=\"auto\"\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ctable dir=\"auto\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth data-col-size=\"md\"\u003eFeature\u003c\/th\u003e\n\u003cth data-col-size=\"lg\"\u003eBenefit\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003e240W Additional Power Output\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eExpands system capacity to cover more zones with reliable amplification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003e6 Additional Speaker Zones\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eProvides individual selection and volume control for precise audio distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eContinuous Speaker Line Monitoring\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eDetects faults (short\/open\/ground) automatically for maintained system integrity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eLocal Audio Input\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eAllows zone-specific broadcasts or BGM without affecting the main unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003e8 General Control Inputs\/Outputs\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eEnables integration with external triggers or devices for automated responses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eVM Link RJ45 Connectivity\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eSimplifies cascading with CAT5-STP cable up to 800m for distributed setups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eUL2572\/UL864 Compliance\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eEnsures certified performance in North American mass notification and fire systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eFault Status Reporting\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eRelays errors to the main unit for centralized monitoring and quick resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv dir=\"auto\"\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ctable dir=\"auto\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth data-col-size=\"md\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-col-size=\"lg\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eRated Output Power\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e240 W (100 V line); 200 W (UL2572\/CAN\/ULC-S576 compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eSpeaker Zones\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e6 (with attenuators and selectors)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eFrequency Response\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e50 Hz - 20 kHz (±3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eDistortion\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e≤0.7% (at rated output, 1 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eS\/N Ratio\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e≥85 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eAudio Inputs\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eLocal line input (removable terminal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eOutputs\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e6 speaker zones (removable terminal blocks)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eControl Interfaces\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e8 general inputs\/outputs; alarm controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eLink Connector\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eRJ45 (VM Link to VM-3240VA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003ePower Source\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e120 V AC, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e690 VA (rated); 260 W (UL60065); 63 W (idle)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eDimensions (W × H × D)\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e482 × 133 × 431 mm (18.98\" × 5.24\" × 16.97\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e16.5 kg (36.38 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eFinish\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eBlack steel case, aluminum panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e0 °C to +49 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv dir=\"auto\"\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ctable dir=\"auto\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth data-col-size=\"md\"\u003eAspect\u003c\/th\u003e\n\u003cth data-col-size=\"lg\"\u003eTOA VM-3240E AMQ\u003c\/th\u003e\n\u003cth data-col-size=\"md\"\u003eTOA VM-3240VA AMQ\u003c\/th\u003e\n\u003cth data-col-size=\"md\"\u003eTOA VP-2421\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eOutput Power\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e240 W\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003e240 W\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003e420 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eRole\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eExtension (adds zones)\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003eMain (control + amp)\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003eStandalone power amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eZones\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eAdditional 6\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003e6 base\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003eSingle channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eBuilt-in Controls\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eZone selectors\/attenuators\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003eFull inputs + messages\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003eBasic (with module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eSpeaker Monitoring\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eYes (continuous)\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eLocal Input\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eYes\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003eMultiple MIC\/LINE\/BGM\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003eVia module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eExpansion\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eCascade up to 9 (60 zones total)\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003eMaster unit\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003eNot applicable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eCompliance\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eUL2572\/UL864\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003eUL2572\/UL864\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003eGeneral PA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp dir=\"auto\"\u003eFAQ\u003c\/p\u003e\n\u003cul dir=\"auto\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the main purpose of the VM-3240E AMQ?\u003c\/strong\u003e It extends the VM-3240VA AMQ by adding 240W power and 6 more speaker zones with full monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many extension units can be connected?\u003c\/strong\u003e Up to 9 VM-3240E AMQ units to one VM-3240VA AMQ for a total of 60 zones (non-UL limits higher).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat cable is used for linking?\u003c\/strong\u003e Category 5 Shielded Twisted-Pair straight cable (CAT5-STP) via RJ45, up to 800m.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes it have built-in messages or inputs?\u003c\/strong\u003e No, it relies on the main VM-3240VA for messages; it has local line input for zone-specific audio.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat certifications does it support?\u003c\/strong\u003e Compliant with UL2572, CAN\/ULC-S576, and UL864 when used in the VM-3000 system.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"TOA","offers":[{"title":"Default Title","offer_id":46740517912812,"sku":"VM-3240E  AMQ","price":4143.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/CN_VM-3240EAMQ.jpg?v=1775826727","url":"https:\/\/creationnetworks.net\/products\/toa-vm-3240eamq-vm-extension-amplifier-240w-ul-2572-864","provider":"Creation Networks","version":"1.0","type":"link"}