{"product_id":"toa-tt-104b304l-programmable-timer-4-control-outputs-black-1u-optional-rack-kit-mb-15b","title":"TOA TT-104B 304L 4-Channel Programmable Timer","description":"\u003cp dir=\"auto\"\u003eThe \u003cstrong\u003eTOA TT-104B 304L\u003c\/strong\u003e is a reliable programmable timer that provides four independent output channels for automated control of broadcasts, events, or equipment activation in professional audio and facility management systems.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eIt offers weekly scheduling with up to 30 steps per channel in 1-minute increments, easy front-panel programming, pause mode for interruptions, and no-voltage make contact outputs that pulse for 5 seconds at programmed times.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThis unit suits schools, factories, offices, retail spaces, houses of worship, and public facilities for timed announcements, bell signals, lighting control, or equipment triggers, with rack-mountable design and power outage protection for critical reliability.\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv dir=\"auto\"\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ctable dir=\"auto\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth data-col-size=\"md\"\u003eFeature\u003c\/th\u003e\n\u003cth data-col-size=\"lg\"\u003eBenefit\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003e4 Independent Output Channels\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eControls up to 4 separate events or broadcasts simultaneously for multi-task automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003e30 Steps per Channel Weekly\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eEnables detailed scheduling of up to 30 timed actions per channel with 1-minute precision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eEasy Key-Based Programming\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eSimplifies setup with individual keys and display for quick, error-free configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003ePause Mode Functionality\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eHalts all outputs temporarily without deleting programs, ideal for holidays or maintenance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003e5-Second Pulse Output\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eProvides reliable no-voltage make contact trigger for external relays or devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eBuilt-in Error Buzzer\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eAudibly alerts to incorrect key entries, reducing programming mistakes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eChannel Assignment Switch\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eConverts B\/C\/D outputs to A for consolidated control when fewer channels are needed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003e100-Hour Power Outage Protection\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eMaintains clock and programs during extended outages for uninterrupted scheduling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv dir=\"auto\"\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ctable dir=\"auto\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth data-col-size=\"md\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-col-size=\"lg\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003ePower Source\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e110-120 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eOutput Channels\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e4 (A, B, C, D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eOutput Type\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eNo-voltage make contact (5-second pulse)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eOutput Rating\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e24 V DC, 0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eProgram Capacity\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e30 steps per channel (weekly)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eClock Accuracy\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e±5 seconds per month (at 25°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003ePower Outage Backup\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eApproximately 100 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eDay of week, hour, minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e0°C to +50°C (32°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eDimensions (W × H × D)\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e420 × 47.5 × 246.5 mm (16.54\" × 1.87\" × 9.7\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e2.5 kg (5.51 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eFinish\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003ePanel: Aluminum black; Case: Pre-coated steel black\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eAccessories\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eOptional rack-mount bracket MB-15B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv dir=\"auto\"\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ctable dir=\"auto\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth data-col-size=\"lg\"\u003eAspect\u003c\/th\u003e\n\u003cth data-col-size=\"md\"\u003eTOA TT-104B 304L\u003c\/th\u003e\n\u003cth data-col-size=\"sm\"\u003eInter-M PT-100\u003c\/th\u003e\n\u003cth data-col-size=\"md\"\u003eSystem Sensor PTS-4\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"lg\"\u003eOutput Channels\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003e4 independent\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\"\u003e4\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"lg\"\u003eProgram Steps per Channel\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003e30 weekly\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\"\u003e20 daily\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003e50 events\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"lg\"\u003eOutput Type\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003e5-second pulse dry contact\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\"\u003eContinuous or pulse\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003ePulse\/contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"lg\"\u003ePower Outage Backup\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003e100 hours\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\"\u003e24 hours\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003eBattery optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"lg\"\u003eClock Accuracy\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003e±5 sec\/month\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\"\u003e±10 sec\/month\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003e±5 sec\/month\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"lg\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003e3 W\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\"\u003e5 W\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003e4 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"lg\"\u003eRack Mountable\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003eYes (1U with bracket)\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\"\u003eYes\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"lg\"\u003eAdditional Features\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003ePause mode, error buzzer\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\"\u003eBasic display\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003eNetworkable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp dir=\"auto\"\u003eFAQ\u003c\/p\u003e\n\u003cul dir=\"auto\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many programs can the TT-104B store?\u003c\/strong\u003e Up to 30 steps per channel weekly, with independent scheduling for each of the 4 channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat type of output does it provide?\u003c\/strong\u003e No-voltage make contact that closes for 5 seconds at the programmed time, rated at 24 V DC, 0.5 A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes it retain settings during power loss?\u003c\/strong\u003e Yes, clock and programs are maintained for approximately 100 hours.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow is programming done?\u003c\/strong\u003e Easily via front-panel keys with display; includes buzzer for error indication.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan it be rack mounted?\u003c\/strong\u003e Yes, with optional MB-15B bracket for 1U EIA-standard rack installation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"TOA","offers":[{"title":"Default Title","offer_id":46740517421292,"sku":"TT-104B   304L","price":1050.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/CN_TT-104B304L.jpg?v=1775826645","url":"https:\/\/creationnetworks.net\/products\/toa-tt-104b304l-programmable-timer-4-control-outputs-black-1u-optional-rack-kit-mb-15b","provider":"Creation Networks","version":"1.0","type":"link"}