{"product_id":"toa-sx-2000ci-sx-2000-system-control-input-unit","title":"TOA SX-2000CI Control Input Unit","description":"\u003cp dir=\"auto\"\u003eThe TOA SX-2000CI is a control input expansion unit for the SX-2000 Series matrix system, providing 32 independent no-voltage make-contact inputs for triggering system functions, zone selection, priority broadcasts, or external events in large-scale public address and voice evacuation applications.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eBuilt in a durable 2U rack-mountable steel chassis with black finish, it enables automated or manual control via external switches, sensors, timers, or fire alarm panels, enhancing system responsiveness and integration for mission-critical environments.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eIdeal for airports, railway stations, stadiums, large offices, hospitals, shopping malls, educational campuses, and multi-building facilities requiring programmable external triggering alongside audio distribution, it connects via dedicated control bus to the SX-2000SM master unit for seamless, reliable operation.\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv dir=\"auto\"\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ctable dir=\"auto\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth data-col-size=\"md\"\u003eFeature\u003c\/th\u003e\n\u003cth data-col-size=\"lg\"\u003eBenefit\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003e32 Independent Control Inputs\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eTriggers up to 32 separate system actions or events simultaneously for comprehensive automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eNo-Voltage Make-Contact Inputs\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eSafely interfaces with external switches, sensors, timers, or fire alarm contacts without voltage conflicts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eProgrammable Functionality\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eAssigns inputs to zone selection, priority broadcasts, message playback, or custom functions via system software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eExpandable System Design\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eAdds multiple SX-2000CI units for hundreds of control points in large-scale installations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003e2U Rack-Mountable Chassis\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eFits standard 19\" racks for professional, space-efficient deployment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eReliable Control Bus Connection\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eEnsures stable communication with SX-2000SM master unit over dedicated link\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eFault Monitoring\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eReports input status and connection issues to the central matrix for system supervision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eHigh Reliability\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eSupports critical applications with robust construction and secure terminal connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv dir=\"auto\"\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ctable dir=\"auto\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth data-col-size=\"md\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-col-size=\"lg\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003ePower Source\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eSupplied from SX-2000 system (24 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eApprox. 200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eControl Inputs\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e32 channels (no-voltage make-contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eInput Type\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eDry contact (short\/open detection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eInput Rating\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e24 V DC \/ 0.5 A (make-contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eControl\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eProgrammable via SX-2000 system software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eConnection\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eDedicated control bus to SX-2000SM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eDimensions (W × H × D)\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e482 × 88.4 × 257 mm (19\" × 3.48\" × 10.12\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e4.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eFinish\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eBlack surface-treated steel plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e0 °C to +40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv dir=\"auto\"\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ctable dir=\"auto\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth data-col-size=\"sm\"\u003eAspect\u003c\/th\u003e\n\u003cth data-col-size=\"lg\"\u003eTOA SX-2000CI\u003c\/th\u003e\n\u003cth data-col-size=\"lg\"\u003eTOA SX-2000CO Output Unit\u003c\/th\u003e\n\u003cth data-col-size=\"lg\"\u003eBosch PVA-20ARD Relay Module\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"sm\"\u003eFunction\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eControl inputs (32)\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eControl outputs (16 relays)\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eRelay control (20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"sm\"\u003eType\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eMake-contact inputs\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eMake-contact outputs\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eRelay contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"sm\"\u003ePrimary Use\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eExternal triggers (switches\/sensors)\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eExternal device activation\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eExternal device control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"sm\"\u003eRating per Channel\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e24 V DC \/ 0.5 A\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e24 V DC \/ 0.5 A; 250 V AC \/ 0.5 A\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e30 V DC \/ 2 A; 250 V AC \/ 2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"sm\"\u003eExpandability\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eMultiple units\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eMultiple units\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eModular expansion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"sm\"\u003eIntegration\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eSX-2000 matrix control bus\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eSX-2000 matrix control bus\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eBosch Plena\/VAS systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"sm\"\u003eRack Size\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e2U\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e2U\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"sm\"\u003eTypical Application\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eFire alarm, timers, switches\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eLights, doors, signals\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eGeneral relay control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp dir=\"auto\"\u003eFAQ\u003c\/p\u003e\n\u003cul dir=\"auto\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat system is the SX-2000CI compatible with?\u003c\/strong\u003e It is designed exclusively for the TOA SX-2000 Series matrix system, connecting to the SX-2000SM master unit via the dedicated control bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat can trigger the inputs?\u003c\/strong\u003e Any dry contact (no-voltage make-contact) devices such as external switches, sensors, timers, fire alarm panels, or access control systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many control inputs are available?\u003c\/strong\u003e 32 independent inputs per unit, expandable by adding multiple SX-2000CI modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow are inputs programmed?\u003c\/strong\u003e Through the SX-2000 system software, allowing assignment to zone selection, priority levels, message playback, or custom functions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs it suitable for emergency voice evacuation?\u003c\/strong\u003e Yes, it can be programmed for emergency-related triggers (e.g., fire alarm activation, evacuation signals) within a certified SX-2000 VA system.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"TOA","offers":[{"title":"Default Title","offer_id":46740515422444,"sku":"SX-2000CI","price":2063.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/CN_SX-2000CI.jpg?v=1775826364","url":"https:\/\/creationnetworks.net\/products\/toa-sx-2000ci-sx-2000-system-control-input-unit","provider":"Creation Networks","version":"1.0","type":"link"}