{"product_id":"toa-n-8000micu-n-8000-ip-intercom-multi-interface-unit-2-audio-line-inputs-2-audio-line-outputs-16-control-i-o-rack-and-wall-mount-kit-included","title":"TOA N-8000MI CU Multi-Interface Unit - 16 I\/O, BGM, Paging Control, IP-Enabled","description":"\u003cp dir=\"auto\"\u003eThe TOA N-8000MI CU Multi-Interface Unit expands the N-8000 Series IP intercom system with extensive external control and audio integration capabilities, featuring 16 control inputs for triggering calls\/paging via external switches or sensors, 16 open-collector control outputs for activating indicators, relays, or CCTV, 4 analog audio inputs for background music or external sources, and 2 balanced paging outputs with independent volume control. It enables advanced functions such as automatic paging activation, time-based scheduling, BGM distribution, and integration with fire alarms, access control, or third-party systems.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eHoused in a 1U rack-mountable pre-coated steel chassis (black finish) with forced air cooling, it connects via 10\/100BASE-TX Ethernet and uses sub-band ADPCM encoding with cryptosystem and packet loss recovery for reliable performance across LAN\/WAN.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eFully compatible with all N-8000 Series exchanges, master stations, door stations, paging gateways, and sub-station interfaces, supporting massive systems up to 192 LAN-connected devices for complex installations in airports, campuses, hospitals, correctional facilities, and large commercial buildings.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eFeatures Chart\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv dir=\"auto\"\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ctable dir=\"auto\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth data-col-size=\"md\"\u003eFeature\u003c\/th\u003e\n\u003cth data-col-size=\"lg\"\u003eBenefit\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003e16 Control Inputs\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eTriggers intercom functions from external sensors, switches, or alarm systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003e16 Open-Collector Outputs\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eActivates external devices like strobes, locks, CCTV, or indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003e4 Analog Audio Inputs\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eDistributes up to 4 BGM channels or external program sources system-wide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003e2 Balanced Paging Outputs\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eDirect connection to PA amplifiers with independent volume and zone control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eIP Network Integration\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eFull remote control and audio routing over standard LAN\/WAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eContact Closure \u0026amp; Relay Control\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eSeamless integration with fire panels, access control, and building management\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003ePacket Loss Recovery\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eMaintains audio quality with silence insertion during network issues\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003e1U Rack-Mount Design\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eProfessional installation in equipment racks or control rooms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp dir=\"auto\"\u003eSpecifications Table\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv dir=\"auto\"\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ctable dir=\"auto\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth data-col-size=\"md\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-col-size=\"lg\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eModel\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eTOA N-8000MI CU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003ePower Source\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e120 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e18 W (rated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e420 (W) × 44.3 (H) × 325 (D) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e3.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eFinish\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003ePre-coated steel plate, black\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eMounting\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eRack (1U EIA standard), desk\/surface, wall (optional brackets)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eControl Inputs\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e16 no-voltage make contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eControl Outputs\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e16 open-collector (max 50 V DC, 100 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eAudio Inputs\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e4 line level (0 dB*, 10 kΩ), removable terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003ePaging Outputs\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e2 balanced line level (0 dB*, 600 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eNetwork Interface\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e10BASE-T\/100BASE-TX (RJ45 auto-negotiation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eNetwork Protocols\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eTCP\/IP, UDP, HTTP, RTP, ARP, ICMP, IGMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eVoice Encoding\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eSub-band ADPCM with cryptosystem\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003ePacket Loss Recovery\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eSilence insertion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e0°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e90% RH or less (no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp dir=\"auto\"\u003eCompare Chart\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv dir=\"auto\"\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ctable dir=\"auto\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth data-col-size=\"md\"\u003eAspect\u003c\/th\u003e\n\u003cth data-col-size=\"lg\"\u003eTOA N-8000MI CU\u003c\/th\u003e\n\u003cth data-col-size=\"lg\"\u003eTOA N-8000SGQ2 (Paging Gateway)\u003c\/th\u003e\n\u003cth data-col-size=\"lg\"\u003eTOA N-8400RS (Sub-station Interface)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003ePrimary Function\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eMulti-I\/O + BGM + paging control\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eDedicated paging gateway\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eAnalog sub-station bridge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eControl Inputs\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e16\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eBasic (trigger inputs)\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eControl Outputs\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e16 open-collector\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eBasic status outputs\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eAudio Inputs\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e4 BGM\/program\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eNone\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003ePaging Outputs\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e2 balanced\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e2 balanced\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eStation paging only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eMounting\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eRack 1U\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eRack 1U\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eRack 1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eBest For\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eFull system integration \u0026amp; automation\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eIntercom-to-PA bridging\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eLegacy sub-station integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp dir=\"auto\"\u003eFAQ\u003c\/p\u003e\n\u003cul dir=\"auto\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the main purpose of the N-8000MI CU?\u003c\/strong\u003e It serves as the \"Swiss Army knife\" of the N-8000 system, providing extensive external I\/O control, BGM distribution, and paging outputs for complex integrations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan it distribute background music?\u003c\/strong\u003e Yes, it accepts up to 4 analog audio sources and distributes them system-wide as selectable BGM channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many external devices can it control?\u003c\/strong\u003e 16 open-collector outputs can activate relays, lights, locks, CCTV, or other devices (max 50 V DC \/ 100 mA each).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes it connect directly to PA amplifiers?\u003c\/strong\u003e Yes, via 2 balanced line-level paging outputs with independent volume control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs it rack-mountable?\u003c\/strong\u003e Yes, standard 1U EIA rack size with included mounting brackets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many can be used in one system?\u003c\/strong\u003e Multiple units can be networked; total system supports up to 192 LAN-connected components.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"TOA","offers":[{"title":"Default Title","offer_id":46740505559276,"sku":"N-8000MICU","price":3110.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/CN_N-8000MICU.jpg?v=1775825410","url":"https:\/\/creationnetworks.net\/products\/toa-n-8000micu-n-8000-ip-intercom-multi-interface-unit-2-audio-line-inputs-2-audio-line-outputs-16-control-i-o-rack-and-wall-mount-kit-included","provider":"Creation Networks","version":"1.0","type":"link"}