{"product_id":"toa-da-250dcu-digital-power-amplifier-2x-250-w-4ω-2x-170-w-8ω-1x-500-w-bridged-8ω-1u","title":"TOA DA-250D CU Digital Power Amplifier - 250 W × 2 Channels, Class D, Low-Impedance","description":"\u003cp dir=\"auto\"\u003eThe TOA DA-250D CU is a high-efficiency Class D digital power amplifier delivering 250 W per channel (total 500 W) with low-impedance output modes (4 Ω \/ 8 Ω). It features low distortion, high reliability, and forced-air cooling for continuous operation in demanding environments, making it suitable for background music, paging, announcements, voice reinforcement, and multi-zone sound systems in schools, offices, retail stores, stadiums, transit stations, factories, and large commercial facilities.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe amplifier includes 2 independent channels, input level controls, LED indicators for power, signal, peak, and protect, and comprehensive protection circuits for thermal, overload, and short-circuit conditions. It supports bridged mode for single-channel 500 W output and integrates seamlessly with TOA 9000M2\/900 Series mixers, N-8000\/N-8600 intercom systems, or IP interfaces for complete audio solutions.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eFeatures Chart\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv dir=\"auto\"\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ctable dir=\"auto\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth data-col-size=\"md\"\u003eFeature\u003c\/th\u003e\n\u003cth data-col-size=\"lg\"\u003eBenefit\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003e250 W × 2 Channels (500 W total)\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eHigh power for large zones or speaker arrays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eLow-Impedance Outputs (4 Ω \/ 8 Ω)\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eOptimized for direct-drive installations and short cable runs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eClass D Efficiency\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eLow heat generation and high energy efficiency for 24\/7 use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eForced-Air Cooling\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eMaintains reliable performance during continuous operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eBridged Mode Support\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eCombines channels for 500 W single-channel output when needed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eComprehensive Protection Circuits\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eThermal, overload, short-circuit, and DC protection for safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eLED Indicators\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003ePower, signal, peak, protect, and channel status at a glance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003e2U Rack-Mount Design\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eFits standard 19-inch equipment racks for professional installations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp dir=\"auto\"\u003eSpecifications Table\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv dir=\"auto\"\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ctable dir=\"auto\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth data-col-size=\"md\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-col-size=\"lg\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eModel\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eTOA DA-250D CU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003ePower Source\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e120 V AC, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e650 W (rated output), 100 W (idle)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eRated Output\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e250 W × 2 (4 Ω \/ 8 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eFrequency Response\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e20 Hz – 20 kHz (±1 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eTotal Harmonic Distortion\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e0.1% or less (1 kHz, rated output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eSignal to Noise Ratio\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e100 dB or better (A-weighted)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eInputs\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e2 balanced (removable terminal block or XLR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eOutputs\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e2 channels (removable terminal block for speakers)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eCooling\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eForced-air (variable speed fan)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eMounting\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eRack-mount (2U, includes brackets)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e482 (W) × 88.4 (H) × 377 (D) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eFinish\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e0°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp dir=\"auto\"\u003eCompare Chart\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv dir=\"auto\"\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ctable dir=\"auto\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth data-col-size=\"md\"\u003eAspect\u003c\/th\u003e\n\u003cth data-col-size=\"lg\"\u003eTOA DA-250D CU\u003c\/th\u003e\n\u003cth data-col-size=\"lg\"\u003eTOA DA-250FH CU (High-Impedance)\u003c\/th\u003e\n\u003cth data-col-size=\"lg\"\u003eTypical Competitor 2-Ch Amp (e.g., Crown XLi 3500)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003ePower per Channel\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e250 W (4\/8 Ω)\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e250 W (70\/100 V)\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e300–600 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eImpedance Options\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e4 Ω \/ 8 Ω\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e70 V \/ 100 V\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e4\/8 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eCooling\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eForced-air\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eForced-air\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eForced-air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eRack Size\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e2U\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e2U\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003e2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003ePrimary Use\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eLow-impedance direct drive\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eHigh-impedance distributed\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eVersatile installed\/live sound\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-col-size=\"md\"\u003eBest For\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eMedium-large venue reinforcement\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eMulti-zone paging\/BGM\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\"\u003eGeneral installed audio\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp dir=\"auto\"\u003eFAQ\u003c\/p\u003e\n\u003cul dir=\"auto\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the DA-250D CU best used for?\u003c\/strong\u003e Low-impedance (4 Ω \/ 8 Ω) sound reinforcement, background music, paging, and voice applications in large venues or zones where direct-drive speakers are used.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes it support 70 V \/ 100 V outputs?\u003c\/strong\u003e No — this model is optimized for low-impedance operation; for high-impedance (70 V \/ 100 V) applications, use models like DA-250FH CU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs it suitable for 24\/7 operation?\u003c\/strong\u003e Yes — Class D efficiency and forced-air cooling support continuous use in commercial environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow is it mounted?\u003c\/strong\u003e Standard 2U rack-mountable with included brackets for 19-inch equipment racks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes it include fan noise?\u003c\/strong\u003e Fan speed varies with temperature for quiet operation in low-load conditions; suitable for noise-sensitive spaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs it compatible with TOA mixers?\u003c\/strong\u003e Yes — pairs with TOA 9000M2\/900 Series mixers, N-8000\/N-8600 intercom systems, or IP interfaces for complete audio solutions.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"TOA","offers":[{"title":"Default Title","offer_id":46740491698412,"sku":"DA-250DCU","price":1386.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/CN_DA-250DCU.jpg?v=1775824033","url":"https:\/\/creationnetworks.net\/products\/toa-da-250dcu-digital-power-amplifier-2x-250-w-4%cf%89-2x-170-w-8%cf%89-1x-500-w-bridged-8%cf%89-1u","provider":"Creation Networks","version":"1.0","type":"link"}