{"product_id":"rf-venue-lilac-mic-disinfector-lilac-microphone-disinfector","title":"RF Venue Li.LAC Mic Disinfector – UV-C Microphone Sanitization System","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe RF Venue Li.LAC Microphone Disinfector is a professional 3RU rackmount UV-C disinfection system designed for sanitizing handheld microphones, wireless transmitters, headsets, lavalier microphones, and beltpack transmitters in commercial AV environments. Using dual OSRAM Puritec germicidal UV-C lamps at 254 nm, the Li.LAC delivers a laboratory-verified minimum UV-C dose of 112 mJ\/cm² per 5-minute cycle, achieving 99.99% surface disinfection. Engineered and manufactured in Germany, with disinfection performance independently validated by the University Medical Center Groningen, the Li.LAC addresses the hygiene requirements of shared microphone use in conference rooms, houses of worship, schools, broadcast studios, and live event venues.\u003c\/p\u003e\n\n\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eShared microphones in high-traffic AV environments — conference rooms, houses of worship, lecture halls, broadcast studios, and live event venues — transfer bacteria and viruses between users with every handoff. The Li.LAC Microphone Disinfector provides a fast, effective, and automated method for sanitizing microphone surfaces between uses without damaging sensitive acoustic components, foam windscreens, or metal grilles.\u003c\/p\u003e\n\u003cp\u003eThe Li.LAC chamber accommodates up to three handheld microphones or wireless transmitters simultaneously on a stainless steel grille. An included steel coil and magnetic plate extend capacity to headsets, lavalier\/clip-on microphones, and beltpack transmitters. Customized UV-C mirrors line all interior boundaries of the chamber to maximize irradiance distribution and ensure consistent disinfection across the full surface of each microphone, including the rear and sides.\u003c\/p\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/DSC_8348-transparent.png?v=1757950989\" alt=\"RF Venue Li.LAC Mic Disinfector – UV-C Microphone Sanitization System - Creation Networks\" style=\"max-width:100%;height:auto;\"\u003e\n\u003cp\u003eOperation is straightforward: place microphones on the grille, close the chamber, and press start. A standard cycle runs 5 to 10 minutes. The Li.LAC incorporates a safety interlock switch that immediately shuts off the UV-C lamps if the chamber is opened during an active cycle, preventing UV exposure to operators. Built-in electrical monitoring continuously tracks UV-C lamp health status. The dual OSRAM lamps are rated to 9,000 operating hours, with RF Venue recommending replacement after 5,000 disinfection cycles to maintain peak disinfection performance.\u003c\/p\u003e\n\u003cp\u003eDisinfection efficacy has been independently validated at two levels: laboratory testing by Opsytec Dr. Gröbel GmbH (DAkkS-accredited, accreditation D-PL-20284-01-00) confirms a minimum irradiance of 373 µW\/cm² and a minimum dose of 112 mJ\/cm² per 5-minute cycle. A clinical study by the Departments of Biomedical Engineering and Medical Microbiology at the University Medical Center Groningen (UMCG) demonstrated 99.3% reduction of viral load on strongly contaminated microphones after a 10-minute irradiation cycle. The Li.LAC won Best of Show at ISE 2024 in the Mix category.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual OSRAM Puritec UV-C Lamps\u003c\/strong\u003e — Two 16W germicidal UV-C lamps at 254 nm (ozone-free) provide laboratory-verified disinfection performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLab-Verified 99.99% Surface Disinfection\u003c\/strong\u003e — Independently verified by Opsytec Dr. Gröbel GmbH (DAkkS D-PL-20284-01-00); 112 mJ\/cm² minimum UV-C dose per 5-minute cycle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3-Microphone Capacity\u003c\/strong\u003e — Accommodates up to 3 handheld microphones or wireless transmitters simultaneously; steel coil and magnetic plate extend capacity to headsets, lavalieres, and beltpacks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5-Minute Standard Cycle\u003c\/strong\u003e — Fast turnaround for high-throughput environments such as conference centers and live event venues.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Interlock\u003c\/strong\u003e — Automatic UV-C shutdown if chamber is opened during an active cycle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUV-C Lamp Health Monitoring\u003c\/strong\u003e — Built-in electrical monitoring of lamp status for proactive maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniversal Voltage\u003c\/strong\u003e — 110–240 VAC, 50\/60 Hz auto-switching power supply for worldwide deployment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMade in Germany\u003c\/strong\u003e — Engineered and manufactured by iSEMcon in Germany; 24-month product warranty (UV-C lamps and wearing parts excluded).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3RU Rack Mount\u003c\/strong\u003e — Standard 19-inch 3U format for integration into AV equipment racks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eISE 2024 Best of Show\u003c\/strong\u003e — Recognized at Integrated Systems Europe 2024, Mix category.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cp\u003eSuitable for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConference rooms and boardrooms with shared wireless microphones\u003c\/li\u003e\n\u003cli\u003eHouses of worship with handheld microphones passed between multiple speakers or worship leaders\u003c\/li\u003e\n\u003cli\u003eAuditoriums and lecture halls with shared handheld or lavalier microphones\u003c\/li\u003e\n\u003cli\u003eBroadcast studios and radio stations requiring hygiene protocols for talent microphones\u003c\/li\u003e\n\u003cli\u003eGovernment and municipal facilities with shared microphone use in council chambers and public hearing rooms\u003c\/li\u003e\n\u003cli\u003eSchools, universities, and training rooms with shared AV equipment\u003c\/li\u003e\n\u003cli\u003eLive event and touring sound companies with back-line microphone pools\u003c\/li\u003e\n\u003cli\u003eCorporate all-hands rooms and multi-purpose meeting spaces\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"width:100%;border-collapse:collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUV-C Lamp Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2× OSRAM Puritec HNS 16W G5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUV-C Wavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e254 nm (ozone-free germicidal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLamp Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2× 16W (32W total UV-C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUV-C Lamp Rated Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,000 operating hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Lamp Replacement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAfter 5,000 disinfection cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Irradiance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e373 µW\/cm² (lab-verified)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum UV-C Dose (5-min cycle)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e112 mJ\/cm² (lab-verified)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisinfection Cycle Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5–10 minutes (+ 2-minute cold preheat from cold start)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMicrophone Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 3 handheld mics\/transmitters; headsets and lavalieres via included accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisinfection Performance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e99.99% surface disinfection (lab-verified); 99.3% viral load reduction (UMCG clinical study)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Interlock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic UV-C shutdown on chamber open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLamp Monitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in electrical lamp health monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110–240 VAC~ (±10%), 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to +45°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3RU rackmount, 19-inch standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e482 × 132 × 390 mm (18.97\" × 5.19\" × 15.35\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11.5 kg (25.3 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Manufacture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 months (UV-C lamps and wearing parts excluded)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLab Verification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpsytec Dr. Gröbel GmbH (DAkkS D-PL-20284-01-00)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eHow does UV-C disinfection work on microphones?\u003c\/h3\u003e\n\u003cp\u003eUV-C light at 254 nm damages the DNA and RNA of bacteria and viruses on exposed surfaces, preventing them from replicating. The Li.LAC’s interior mirror system distributes UV-C energy across all surfaces of the microphone, including the grille, body, and foam windscreen. The minimum UV-C dose of 112 mJ\/cm² per standard cycle is independently verified to achieve 99.99% surface disinfection.\u003c\/p\u003e\n\u003ch3\u003eDoes UV-C disinfection damage microphones or their components?\u003c\/h3\u003e\n\u003cp\u003eThe Li.LAC is specifically designed for microphone use. UV-C at 254 nm does not generate ozone (the lamps are ozone-free) and does not produce significant heat. The cycle parameters have been validated with standard microphone types including handheld dynamics, condensers, wireless transmitters, and their associated foam windscreens and metal grilles.\u003c\/p\u003e\n\u003ch3\u003eHow many microphones can be disinfected in each cycle?\u003c\/h3\u003e\n\u003cp\u003eUp to 3 handheld microphones or wireless transmitters can be placed simultaneously on the stainless steel grille. The included steel coil and magnetic plate accessories extend the system to headsets, lavalier microphones, and beltpack transmitters. Multiple items can be processed in a single cycle.\u003c\/p\u003e\n\u003ch3\u003eWhat is the clinical validation behind the Li.LAC?\u003c\/h3\u003e\n\u003cp\u003eA peer-reviewed study from the Departments of Biomedical Engineering and Medical Microbiology at the University Medical Center Groningen (UMCG, the Netherlands) demonstrated 99.3% reduction of viral load on heavily contaminated microphones after a 10-minute irradiation cycle. The study used M13 bacteriophage as the test organism, with results correlated to influenza virus (H1N1) and SARS-CoV-2 behavior on solid surfaces.\u003c\/p\u003e\n\u003ch3\u003eWhen should the UV-C lamps be replaced?\u003c\/h3\u003e\n\u003cp\u003eThe OSRAM Puritec HNS 16W G5 lamps are rated to 9,000 operating hours. RF Venue recommends lamp replacement after 5,000 disinfection cycles to maintain optimum disinfection performance. Built-in lamp health monitoring alerts operators when lamp status changes.\u003c\/p\u003e\n\u003ch3\u003eIs the Li.LAC safe to operate in a shared space?\u003c\/h3\u003e\n\u003cp\u003eYes. The Li.LAC includes a safety interlock switch that automatically shuts off all UV-C lamps the moment the chamber is opened during an active cycle. The sealed chamber design prevents UV-C radiation from reaching operators during normal use.\u003c\/p\u003e\n\u003ch3\u003eWhat warranty covers this product?\u003c\/h3\u003e\n\u003cp\u003eThe Li.LAC Microphone Disinfector is covered by a 24-month product warranty (UV-C lamps and wearing parts excluded). Contact Creation Networks at creationnetworks.net for warranty registration and support information.\u003c\/p\u003e","brand":"RF Venue","offers":[{"title":"Default Title","offer_id":46716758393068,"sku":"LILAC MIC DISINFECTOR","price":1999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/DSC_8348-transparent.png?v=1757950989","url":"https:\/\/creationnetworks.net\/products\/rf-venue-lilac-mic-disinfector-lilac-microphone-disinfector","provider":"Creation Networks","version":"1.0","type":"link"}