{"product_id":"rdl-fp-mpa2","title":"RDL FP-MPA2 – Dual Mic Phantom Power Adapter, XLR","description":"\u003ch2\u003eWhat is the RDL FP-MPA2?\u003c\/h2\u003e\u003cp\u003eThe RDL FP-MPA2 is a two-channel phantom power adapter that supplies 12 V, 24 V or 48 V phantom to condenser microphones through XLR connections. Phantom voltage is selectable for each input, and a second switch sets the buildout for 24 V microphones that need lower current. Phantom is blocked from the output, so the adapter can feed mixers or inputs that do not provide phantom power.\u003c\/p\u003e\u003ch2\u003eHow does it work?\u003c\/h2\u003e\u003cp\u003e\u003cimg src=\"https:\/\/rdlnet.com\/wp-content\/uploads\/2024\/01\/fp-mpa2.jpg\" alt=\"RDL FP-MPA2 dual microphone phantom power adapter\" style=\"max-width:100%;height:auto\" loading=\"lazy\"\u003e\u003c\/p\u003e\u003cp\u003eEach of the two identical circuits has a female XLR for the microphone and a male XLR for the signal output. The selected phantom voltage is applied to the input jack and blocked from the output jack. A three-position switch on each channel chooses 12 Vdc, 24 Vdc or 48 Vdc phantom. For 24 V microphones that perform best with higher buildout resistance, a second switch selects 1.2 kΩ NORMAL or 2.4 kΩ LO current, per IEC 61938: 2013. Phantom voltages are generated by a low-noise dc-dc converter and regulator circuits, and each phantom output is short-circuit protected. The module runs on 24 Vdc at 120 mA, ground-referenced. Jack placement allows high-density mounting against flat surfaces, and multiple units can mount to rack sides or rails with the \u003ca href=\"https:\/\/creationnetworks.net\/products\/rdl-fp-rra\"\u003eRDL FP-RRA\u003c\/a\u003e.\u003c\/p\u003e\u003ch2\u003eWhat are the key features?\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo phantom channels\u003c\/strong\u003e — Powers two microphones from one compact module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelectable voltage\u003c\/strong\u003e — Choose 12 V, 24 V or 48 V phantom on each channel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuildout selection\u003c\/strong\u003e — NORMAL or LO current buildout for 24 V microphones.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhantom-blocked outputs\u003c\/strong\u003e — Mic signal passes through to the male XLR without phantom.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-circuit protection\u003c\/strong\u003e — Each phantom output is protected.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFLAT-PAK construction\u003c\/strong\u003e — Ultra-compact all-metal case for rack or surface mounting.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eWhere is it typically used?\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConference room\u003c\/li\u003e\n\u003cli\u003eHouse of worship\u003c\/li\u003e\n\u003cli\u003eBroadcast studio\u003c\/li\u003e\n\u003cli\u003eAuditorium\u003c\/li\u003e\n\u003cli\u003eTraining room\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch\"\u003e\u003ctable style=\"border-collapse:collapse;width:100%;min-width:300px;table-layout:fixed\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width:44%\"\u003e\n\u003ccol style=\"width:56%\"\u003e\n\u003c\/colgroup\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px;vertical-align:top\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eFP-MPA2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px;vertical-align:top\"\u003e\u003cstrong\u003ePower Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e24 Vdc @ 120 mA, Ground-referenced\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px;vertical-align:top\"\u003e\u003cstrong\u003eAmbient Operating Environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e32° F to 122° F (0° C to 50° C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px;vertical-align:top\"\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eXLR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px;vertical-align:top\"\u003e\u003cstrong\u003eSelectable Buildouts (24V only)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e1.2 kΩ NORMAL (standard) or 2.4 kΩ LO (low current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px;vertical-align:top\"\u003e\u003cstrong\u003ePhantom Voltages\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e12 Vdc, 24 Vdc, 48 Vdc (selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px;vertical-align:top\"\u003e\u003cstrong\u003eVoltage and Buildout Standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eIEC 61938: 2013\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px;vertical-align:top\"\u003e\u003cstrong\u003eOutputs (2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eMic signal loop-through\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px;vertical-align:top\"\u003e\u003cstrong\u003eInputs (2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eLow-impedance balanced mic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px;vertical-align:top\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eHeight: 1.42 in. 3.61 cm; Width: 3.25 in. 8.26 cm; Length: 6.67 in. 16.94 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cdetails\u003e\u003csummary\u003e\u003cstrong\u003eWhich phantom voltages are available?\u003c\/strong\u003e\u003c\/summary\u003e\u003cp\u003e12 Vdc, 24 Vdc and 48 Vdc, selectable for each input.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003e\u003cstrong\u003eDoes phantom reach the mixer input?\u003c\/strong\u003e\u003c\/summary\u003e\u003cp\u003eNo. Phantom is applied to the female input jack and blocked from the male output jack.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003e\u003cstrong\u003eWhat standard does it follow?\u003c\/strong\u003e\u003c\/summary\u003e\u003cp\u003eVoltages and buildouts follow IEC 61938: 2013.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003e\u003cstrong\u003eHow is it powered?\u003c\/strong\u003e\u003c\/summary\u003e\u003cp\u003e24 Vdc at 120 mA, ground-referenced.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003e\u003cstrong\u003eHow is it mounted?\u003c\/strong\u003e\u003c\/summary\u003e\u003cp\u003eIt can mount against flat surfaces, on rack sides, or on front or rear rack rails using the RDL FP-RRA.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003e\u003cstrong\u003eWhat warranty does it carry?\u003c\/strong\u003e\u003c\/summary\u003e\u003cp\u003eThis product is covered by a 7-year RDL warranty. For warranty claims, RMAs or support, contact Creation Networks at (888) 230-3661 or sales@creationnetworks.net.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003e\u003cstrong\u003eCan Creation Networks help design the system?\u003c\/strong\u003e\u003c\/summary\u003e\u003cp\u003eYes. Our team specifies, programs and installs microphone and conferencing systems for commercial projects nationwide. Call (888) 230-3661 for a quote or design review.\u003c\/p\u003e\u003c\/details\u003e","brand":"RDL","offers":[{"title":"Default Title","offer_id":68025770606828,"sku":"FP-MPA2","price":320.07,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/fp-mpa2.jpg?v=1793583775","url":"https:\/\/creationnetworks.net\/products\/rdl-fp-mpa2","provider":"Creation Networks","version":"1.0","type":"link"}