{"product_id":"rdl-fp-dcc1","title":"RDL FP-DCC1 – 12 Vdc to 24 Vdc Power Converter","description":"\u003ch2\u003eWhat is the RDL FP-DCC1?\u003c\/h2\u003e\u003cp\u003eThe RDL FP-DCC1 converts a 12 Vdc source to regulated 24 Vdc so RDL audio and video modules can run from battery or vehicle power. It provides a 400 mA high-current output for multiple modules or amplifiers and a separate 50 mA low-noise output for microphone preamplifiers. Overvoltage shutdown, fusing and reverse-voltage protection are built into a compact all-metal FLAT-PAK case.\u003c\/p\u003e\u003ch2\u003eHow does it work?\u003c\/h2\u003e\u003cp\u003e\u003cimg src=\"https:\/\/rdlnet.com\/wp-content\/uploads\/2024\/01\/fp-dcc1.jpg\" alt=\"RDL FP-DCC1 12 Vdc to 24 Vdc converter\" style=\"max-width:100%;height:auto\" loading=\"lazy\"\u003e\u003c\/p\u003e\u003cp\u003eThe FP-DCC1 accepts 11 to 14 Vdc at 1 A on a detachable terminal block and regulates its outputs to 24 Vdc, ground-referenced. The high-current output supplies 400 mA on both a terminal block and a dc power jack, with a combined limit of 400 mA. This output can power several modules through a power distributor, or RDL audio power amplifiers such as the ST-PA2 or ST-PA6. A second, heavily filtered 50 mA output is intended for high-gain microphone-level modules such as mic preamplifiers. Both outputs may be used at the same time. If the input exceeds 15 Vdc, for example from a failed vehicle regulator, the module shuts down and lights the INPUT OVERVOLTAGE LED. Automotive blade fuses protect the input (2 A) and output (1 A), and the circuits are protected against excessive current and reverse voltage. The FP-DCC1 is not intended for floating (bipolar) modules, and it can be rack mounted with the \u003ca href=\"https:\/\/creationnetworks.net\/products\/rdl-fp-hra\"\u003eRDL FP-HRA\u003c\/a\u003e or \u003ca href=\"https:\/\/creationnetworks.net\/products\/rdl-fp-rra\"\u003eRDL FP-RRA\u003c\/a\u003e.\u003c\/p\u003e\u003ch2\u003eWhat are the key features?\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e12 to 24 Vdc conversion\u003c\/strong\u003e — Runs ground-referenced 24 Vdc modules from a 12 Vdc source.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-current output\u003c\/strong\u003e — 400 mA at 24 Vdc on terminal block and dc jack for multiple modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-noise output\u003c\/strong\u003e — A filtered 50 mA output for microphone preamplifiers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvervoltage shutdown\u003c\/strong\u003e — Inputs above 15 Vdc shut the module down and light a warning LED.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFused and protected\u003c\/strong\u003e — Blade fuses plus protection against overcurrent and reverse voltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll-metal FLAT-PAK\u003c\/strong\u003e — Ultra-compact construction for mobile and tight installs.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eWhere is it typically used?\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBroadcast studio\u003c\/li\u003e\n\u003cli\u003eGovernment space\u003c\/li\u003e\n\u003cli\u003eMulti-purpose room\u003c\/li\u003e\n\u003cli\u003eTraining room\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch\"\u003e\u003ctable style=\"border-collapse:collapse;width:100%;min-width:300px;table-layout:fixed\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width:44%\"\u003e\n\u003ccol style=\"width:56%\"\u003e\n\u003c\/colgroup\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px;vertical-align:top\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eFP-DCC1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px;vertical-align:top\"\u003e\u003cstrong\u003eOutputs (3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eOne 24 Vdc regulated @ 400 mA (detachable terminal block) One 24 Vdc regulated @ 400 mA (dc power jack) (Note: The combined load for both the above outputs is 400 mA) One 24 Vdc regulated @ 50 mA filtered (detachable terminal block)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px;vertical-align:top\"\u003e\u003cstrong\u003eFuses (2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eOne 2 A Automotive blade style miniature fuse (Input), One 1 A Automotive blade style miniature fuse (Output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px;vertical-align:top\"\u003e\u003cstrong\u003eAmbient Operating Environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e32° F to 131° F (0° C to 55° C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px;vertical-align:top\"\u003e\u003cstrong\u003ePower Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eGROUND-REFERENCED, 11-14 Vdc @ 1 A, (detachable terminal block)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px;vertical-align:top\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eHeight: 1.25 in. 3.18 cm; Width: 3.25 in. 8.26 cm; Length: 6.54 in. 16.61 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cdetails\u003e\u003csummary\u003e\u003cstrong\u003eWhat input voltage does it accept?\u003c\/strong\u003e\u003c\/summary\u003e\u003cp\u003e11 to 14 Vdc at 1 A, ground-referenced, on a detachable terminal block.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003e\u003cstrong\u003eHow much current can it supply?\u003c\/strong\u003e\u003c\/summary\u003e\u003cp\u003e400 mA at 24 Vdc from the high-current outputs combined, plus 50 mA from the low-noise output.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003e\u003cstrong\u003eCan both outputs be used together?\u003c\/strong\u003e\u003c\/summary\u003e\u003cp\u003eYes. The high-current and low-noise outputs can be used simultaneously.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003e\u003cstrong\u003eWhat happens with a voltage spike?\u003c\/strong\u003e\u003c\/summary\u003e\u003cp\u003eAbove 15 Vdc the module shuts down its circuitry and lights the INPUT OVERVOLTAGE LED.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003e\u003cstrong\u003eWill it power bipolar modules?\u003c\/strong\u003e\u003c\/summary\u003e\u003cp\u003eNo. RDL states the FP-DCC1 is not intended to power floating (bipolar) modules.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003e\u003cstrong\u003eWhat warranty does it carry?\u003c\/strong\u003e\u003c\/summary\u003e\u003cp\u003eThis product is covered by a 7-year RDL warranty. For warranty claims, RMAs or support, contact Creation Networks at (888) 230-3661 or sales@creationnetworks.net.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003e\u003cstrong\u003eCan Creation Networks help design the system?\u003c\/strong\u003e\u003c\/summary\u003e\u003cp\u003eYes. Our team specifies, programs and installs mobile and portable audio systems for commercial projects nationwide. Call (888) 230-3661 for a quote or design review.\u003c\/p\u003e\u003c\/details\u003e","brand":"RDL","offers":[{"title":"Default Title","offer_id":68025770475756,"sku":"FP-DCC1","price":302.45,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/fp-dcc1.jpg?v=1793583774","url":"https:\/\/creationnetworks.net\/products\/rdl-fp-dcc1","provider":"Creation Networks","version":"1.0","type":"link"}