{"product_id":"listen-technologies-lr-5200t-ir-p1-listenir-taa-advanced-idsp-ir-receiver-package-1","title":"Listen Technologies LR-5200T-IR-P1 – ListenIR TAA Advanced iDSP IR Receiver Package 1","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe Listen Technologies LR-5200T-IR-P1 is a TAA-compliant ListenIR advanced idsp ir receiver package 1, built for federal, state and public sector installations where Trade Agreements Act compliance is a procurement requirement. Infrared assistive listening confines the signal to the room, which is why it is specified for courtrooms, boardrooms and any space where the audio must not pass through walls. This package bundles the receiver with its standard listening accessories.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eInfrared and RF solve the same accessibility obligation with opposite properties. RF passes through walls and covers an area; infrared stops at the walls and covers a line of sight. Where confidentiality matters, that containment is the entire point.\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/5200T.png?v=1787627360\" alt=\"Listen Technologies LR-5200T-IR-P1 ListenIR TAA advanced idsp ir receiver package 1\" style=\"max-width:100%;height:auto;\"\u003e\u003c\/p\u003e\u003cp\u003eCourtrooms are the clearest case: proceedings must be audible to those who need assistance and inaudible in the corridor. Boardrooms handling commercially sensitive material follow the same logic. Infrared is also immune to the RF congestion that affects 72 and 216 MHz systems in dense urban sites.\u003c\/p\u003e\u003cp\u003eTAA compliance matters at the procurement stage rather than the technical one. Federal contracts and many state and municipal purchases require it, and a non-compliant part number will fail the bid regardless of technical merit. Listen produces the T-suffix variants specifically for that requirement.\u003c\/p\u003e\u003cp\u003eReceivers are the part of an IR system that patrons handle, so they circulate, get dropped and need charging. Plan the dispensing and charging process alongside the hardware.\u003c\/p\u003e\u003cp\u003eRelated TAA parts: the \u003ca href=\"https:\/\/creationnetworks.net\/products\/listen-technologies-lt-84t-01-listenir-taa-2-channel-transmitter-radiator-combo\"\u003eLT-84T transmitter and radiator combo\u003c\/a\u003e, the \u003ca href=\"https:\/\/creationnetworks.net\/products\/listen-technologies-lr-5200t-ir-p1-listenir-taa-advanced-idsp-ir-receiver-package-1\"\u003eLR-5200T receiver package\u003c\/a\u003e and the \u003ca href=\"https:\/\/creationnetworks.net\/products\/listen-technologies-la-384t-01-listenir-taa-intelligent-4-unit-charging-tray\"\u003eLA-384T 4-unit charging tray\u003c\/a\u003e for fleet charging. Signage is a compliance requirement, covered by the \u003ca href=\"https:\/\/creationnetworks.net\/products\/listen-technologies-la-304-assistive-listening-notification-signage-kit\"\u003eassistive listening notification signage kit\u003c\/a\u003e, and receiver issue is commonly logged in a \u003ca href=\"https:\/\/creationnetworks.net\/products\/listen-technologies-la-904-listen-dispensing-log-book\"\u003edispensing log book\u003c\/a\u003e. Emitter interconnection uses \u003ca href=\"https:\/\/creationnetworks.net\/products\/listen-technologies-la-89-interconnection-coaxial-cable\"\u003einterconnection coaxial cable\u003c\/a\u003e.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTAA compliant\u003c\/strong\u003e — Meets Trade Agreements Act requirements for federal and public sector procurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoom-confined signal\u003c\/strong\u003e — Infrared stops at the walls, keeping proceedings inaudible outside the space.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImmune to RF congestion\u003c\/strong\u003e — Unaffected by the 72 and 216 MHz congestion that degrades RF systems in dense sites.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced intelligent DSP\u003c\/strong\u003e — Digital signal processing improves intelligibility over analog infrared designs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupplied as a package\u003c\/strong\u003e — Bundles the receiver with its standard listening accessories.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuited to confidential proceedings\u003c\/strong\u003e — Specified for courtrooms and boardrooms where audio must not leave the room.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBoardroom\u003c\/li\u003e\n\u003cli\u003eConference room\u003c\/li\u003e\n\u003cli\u003eGovernment space\u003c\/li\u003e\n\u003cli\u003eAuditorium\u003c\/li\u003e\n\u003cli\u003eTraining room\u003c\/li\u003e\n\u003cli\u003eMulti-purpose room\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;min-width:430px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px;border-bottom:1px solid #ddd;\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #ddd;\"\u003eListen Technologies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px;border-bottom:1px solid #ddd;\"\u003ePart Number\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #ddd;\"\u003eLR-5200T-IR-P1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px;border-bottom:1px solid #ddd;\"\u003eProduct Line\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #ddd;\"\u003eListenIR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px;border-bottom:1px solid #ddd;\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #ddd;\"\u003eAdvanced iDSP IR Receiver Package 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px;border-bottom:1px solid #ddd;\"\u003eTechnology\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #ddd;\"\u003eInfrared assistive listening\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px;border-bottom:1px solid #ddd;\"\u003eSignal Processing\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #ddd;\"\u003eAdvanced Intelligent DSP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px;border-bottom:1px solid #ddd;\"\u003eProcurement Compliance\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border-bottom:1px solid #ddd;\"\u003eTAA compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003cem\u003eSpecifications sourced from the Listen Technologies product listing. Confirm radiator coverage against room dimensions before finalising quantities.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eWhy specify infrared instead of RF?\u003c\/strong\u003e\u003cbr\u003e\nInfrared does not pass through walls, so the audio stays in the room. That is required in courtrooms and sensitive boardrooms, and it also avoids the RF congestion that affects 72 and 216 MHz systems in dense urban locations.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat does TAA compliance mean for procurement?\u003c\/strong\u003e\u003cbr\u003e\nThe Trade Agreements Act governs country of origin for federal purchasing, and many state and municipal contracts adopt the same requirement. A non-compliant part number will fail the bid regardless of technical suitability, which is why Listen produces these T-suffix variants.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow many radiators does a room need?\u003c\/strong\u003e\u003cbr\u003e\nCoverage depends on room dimensions, ceiling height and sight lines. Infrared requires line of sight, so balconies, deep rooms and any position shadowed by structure need additional radiators. Confirm the layout before fixing quantities.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan sunlight interfere with the system?\u003c\/strong\u003e\u003cbr\u003e\nInfrared systems can be affected by strong direct sunlight and some lighting types. Assess glazing and lighting during survey, particularly in rooms with large south-facing windows.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow are receivers charged and managed?\u003c\/strong\u003e\u003cbr\u003e\nThrough a charging tray that holds and charges multiple units between sessions. A TAA-compliant 4-unit tray is available for federal installations.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes this part number include receivers?\u003c\/strong\u003e\u003cbr\u003e\nThis is a receiver package including standard listening accessories. Quantities are ordered against the required receiver count.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat warranty and support apply?\u003c\/strong\u003e\u003cbr\u003e\nWarranty duration and technical support terms are set by Listen Technologies. Contact Creation Networks for current terms, RMA handling and pre-sales design support on infrared installations.\u003c\/p\u003e","brand":"Listen Technologies","offers":[{"title":"Default Title","offer_id":48228833853676,"sku":"LR-5200T-IR-P1","price":489.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/5200T.png?v=1787627360","url":"https:\/\/creationnetworks.net\/products\/listen-technologies-lr-5200t-ir-p1-listenir-taa-advanced-idsp-ir-receiver-package-1","provider":"Creation Networks","version":"1.0","type":"link"}