{"product_id":"eaton-suint3000lcd2u-tripp-lite-series-smartonline-3000va-2700w-208-230v-doubleconversion-ups","title":"Eaton SUINT3000LCD2U – 3000VA Double-Conversion Rack UPS","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe Eaton SUINT3000LCD2U is a 3000VA\/2700W double-conversion online UPS designed for facilities that need a double-conversion UPS for AV rack and network equipment where zero transfer time and clean sine wave output are non-negotiable. Operating on 208\/230V input, it is well suited for commercial UPS battery backup installation in data closets and equipment rooms feeding higher-voltage AV and IT infrastructure. Because it continuously regenerates output power rather than switching to battery, it is a preferred choice for an online UPS for commercial AV rack deployments protecting DSP processors, matrix switchers, and network core equipment.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/suint3000lcd2u.jpg?v=1786678609\" alt=\"Eaton SUINT3000LCD2U 3000VA double-conversion UPS\" style=\"max-width:100%;height:auto;\"\u003e\u003cp\u003eThe SUINT3000LCD2U uses double-conversion (online) topology, meaning connected AV and IT equipment is always powered from the UPS's inverter rather than raw utility power, eliminating any transfer delay when the utility fails. This makes it a strong fit for a double-conversion UPS for AV rack deployment where processors and switchers cannot tolerate even momentary power interruption. The unit provides 10 total outlets, 8 IEC C13 and 2 IEC C19, in a 2U rack\/tower chassis, giving integrators flexibility to power a mix of AV amplifiers, network switches, and higher-draw equipment from a single unit. An LCD front panel displays load, battery status, and input\/output conditions at a glance, useful for facilities staff performing routine checks in a data closet. The UPS includes a network card slot, USB, and RS-232 ports for integration with building monitoring systems, along with RPO\/ROO remote shutdown terminals commonly required in commercial UPS battery backup installation projects with centralized emergency power-off requirements. The VRLA battery is expandable with external battery modules for facilities needing longer runtime, positioning this unit as a capable online UPS for commercial AV rack and network infrastructure applications where uptime is the priority.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDouble-Conversion (Online) Topology\u003c\/strong\u003e — Provides zero transfer time by continuously regenerating output power, protecting sensitive AV processors from even brief interruptions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10 Total Outlets (8x C13, 2x C19)\u003c\/strong\u003e — Accommodates a mix of AV and networking equipment power cords in a single rack unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e208\/230V Multi-Voltage Input\u003c\/strong\u003e — Supports flexible commercial power configurations common in AV equipment rooms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLCD Status Display\u003c\/strong\u003e — Gives facilities staff at-a-glance visibility into load, battery, and power conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Card Slot\u003c\/strong\u003e — Accepts an optional SNMP card for centralized remote monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRPO\/ROO Remote Shutdown Terminals\u003c\/strong\u003e — Integrates with building emergency power-off systems required in many commercial installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpandable Battery Runtime\u003c\/strong\u003e — Supports external battery modules for facilities requiring longer ride-through time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2U Rack\/Tower Chassis\u003c\/strong\u003e — Fits standard equipment racks or freestanding deployment in a data closet.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eGovernment space data and communications rooms\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space AV infrastructure\u003c\/li\u003e\n\u003cli\u003eBroadcast studio equipment racks\u003c\/li\u003e\n\u003cli\u003eAuditorium AV and control system racks\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;min-width:480px;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;border-bottom:1px solid #ccc;padding:6px;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"text-align:left;border-bottom:1px solid #ccc;padding:6px;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eCapacity\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e3000VA \/ 2700W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eTopology\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eDouble-conversion (online)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e200\/208\/220\/230\/240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eOutlets\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e8x IEC C13, 2x IEC C19 (10 total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e17.33 in x 3.41 in x 23.82 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e61.29 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eRuntime (full load \/ half load)\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e3.8 min \/ 10.8 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eBattery Type\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eValve-Regulated Lead Acid (VRLA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eCommunication\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eUSB, RS-232, RPO\/ROO terminal, network card slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e2-year limited, worldwide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat makes this UPS different from a line-interactive model?\u003c\/h3\u003e\u003cp\u003eThe SUINT3000LCD2U uses double-conversion (online) topology, meaning it continuously regenerates output power rather than switching to battery, resulting in zero transfer time during a utility failure.\u003c\/p\u003e\u003ch3\u003eWhat outlet types does this UPS provide?\u003c\/h3\u003e\u003cp\u003eIt provides 10 total outlets: 8 IEC C13 and 2 IEC C19, suitable for mixed AV and networking equipment loads.\u003c\/p\u003e\u003ch3\u003eIs this unit compatible with 208V commercial power?\u003c\/h3\u003e\u003cp\u003eYes, it accepts input at 200, 208, 220, 230, or 240 VAC, making it suitable for commercial buildings running higher-voltage circuits to equipment rooms.\u003c\/p\u003e\u003ch3\u003eCan this UPS integrate with building emergency power-off systems?\u003c\/h3\u003e\u003cp\u003eYes, it includes RPO\/ROO remote shutdown terminals for integration with facility emergency power-off requirements.\u003c\/p\u003e\u003ch3\u003eHow is the UPS monitored remotely?\u003c\/h3\u003e\u003cp\u003eAn optional network card slot supports SNMP-based monitoring, in addition to onboard USB and RS-232 ports.\u003c\/p\u003e\u003ch3\u003eWhat is the warranty coverage?\u003c\/h3\u003e\u003cp\u003eThe unit carries a 2-year limited warranty, honored worldwide.\u003c\/p\u003e\u003ch3\u003eCan runtime be extended beyond the built-in battery?\u003c\/h3\u003e\u003cp\u003eYes, the unit supports external battery modules for facilities that require longer runtime during extended outages.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":48159972524268,"sku":"SUINT3000LCD2U","price":2569.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/suint3000lcd2u.jpg?v=1786678609","url":"https:\/\/creationnetworks.net\/products\/eaton-suint3000lcd2u-tripp-lite-series-smartonline-3000va-2700w-208-230v-doubleconversion-ups","provider":"Creation Networks","version":"1.0","type":"link"}