{"product_id":"eaton-suint1500lcd2u-ups-1500va-1350w-intl-smart-online-lcd-usb-db9-208-230v-2urm","title":"Eaton SUINT1500LCD2U – 1500VA 208\/230V Online UPS","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe Eaton SUINT1500LCD2U is a 1500VA\/1350W online double-conversion UPS built for 208\/230V AV and IT installations that require regulated, zero-transfer power. As a 208\/230V online UPS for international AV equipment, it continuously regulates output within 2% of nominal voltage, making it well suited for double-conversion UPS for AV rack deployments outside standard 120V markets. This commercial UPS battery backup installation option meets strict EPA efficiency guidelines while protecting AV and network gear from blackouts, brownouts, and line noise.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/suint1500lcd2u.jpg?v=1786678631\" alt=\"Eaton SUINT1500LCD2U 1500VA 208\/230V online UPS\" style=\"max-width:100%;height:auto;\"\u003e\u003cp\u003eThe SUINT1500LCD2U operates on 200-240V single-phase input with a 208V default, delivering pure sine wave output across the full 200-240V range for international commercial and AV deployments. This zero transfer time UPS for network equipment continuously converts incoming AC to DC and regenerates a fully regulated AC output, so connected devices see no switchover delay when utility power fails. Housed in a 2U rack or tower chassis, it fits into standard AV racks and network closets alongside switches, DSPs, and control processors running on 208\/230V circuits. Eight C13 outlets, arranged in two switchable load banks, let integrators sequence shutdown priorities so mission-critical AV or network equipment stays powered longer than secondary devices. Hot-swappable, user-replaceable VRLA battery modules allow maintenance without powering down the load, and the unit supports up to four optional BP48RT battery packs for extended runtime in critical applications. At 92% efficiency in AC mode and up to 97.5% in economy mode, the SUINT1500LCD2U reduces both operating costs and heat generation in enclosed rack environments. This 2U rackmount UPS with hot-swappable battery is a strong fit for international commercial buildouts, government facilities, and multi-national AV integrations standardizing on 208\/230V power infrastructure.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOnline Double-Conversion Topology\u003c\/strong\u003e — Delivers zero transfer time and continuous voltage regulation regardless of input power quality.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e208-230V International Voltage Support\u003c\/strong\u003e — Operates across a 200-240V input range, suiting commercial deployments outside standard North American voltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-Swappable VRLA Batteries\u003c\/strong\u003e — Enables maintenance and replacement without powering down connected equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEight C13 Outlets in Two Switchable Banks\u003c\/strong\u003e — Allows sequenced shutdown to prioritize critical loads during extended outages.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUp to 97.5% Economy Mode Efficiency\u003c\/strong\u003e — Reduces operating costs and heat output in enclosed AV and network racks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2U Rack\/Tower Form Factor\u003c\/strong\u003e — Fits standard 19-inch racks or operates as a freestanding tower.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpandable Battery Modules\u003c\/strong\u003e — Supports up to four optional BP48RT modules for extended runtime.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eENERGY STAR-Aligned Design\u003c\/strong\u003e — Meets strict EPA efficiency guidelines to help lower total cost of ownership.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eGovernment space AV and network racks running on 208\/230V infrastructure\u003c\/li\u003e\n\u003cli\u003eConference room AV racks in international or multi-national facilities\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space power distribution for 208\/230V equipment\u003c\/li\u003e\n\u003cli\u003eTraining room AV racks in facilities standardized on 230V power\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;min-width:480px;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;border:1px solid #ccc;padding:6px;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"text-align:left;border:1px solid #ccc;padding:6px;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eCapacity\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003e1500 VA \/ 1350 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003e200-240V single-phase, 208V default\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003e200-240V, pure sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eOutlets\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eEight C13 outlets, two switchable load banks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eRuntime at Full Load\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003e5.8 minutes (1350W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eRuntime at Half Load\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003e16 minutes (675W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eTransfer Time\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003e0 ms (zero transfer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eAC Mode Efficiency\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003e92% at full load; 97.5% in economy mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eBattery Type\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eValve Regulated Lead Acid (VRLA), expandable with BP48RT modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003e2U rackmount or tower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003e3.41 in x 17.33 in x 17.72 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003e41.45 lbs (unit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003e2-year limited warranty; $250,000 connected equipment insurance (US\/Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eIs this UPS compatible with 230V AV equipment used internationally?\u003c\/h3\u003e\u003cp\u003eYes, the SUINT1500LCD2U supports a 200-240V input and output range, making it suitable for AV and IT equipment standardized on 208V or 230V power outside North America.\u003c\/p\u003e\u003ch3\u003eWill this unit fit in a standard AV rack?\u003c\/h3\u003e\u003cp\u003eYes, it ships in a 2U rack\/tower chassis with hardware for standard 19-inch racks.\u003c\/p\u003e\u003ch3\u003eCan the battery be replaced without powering down connected equipment?\u003c\/h3\u003e\u003cp\u003eYes, the battery modules are hot-swappable and user-replaceable, allowing maintenance without interrupting connected loads.\u003c\/p\u003e\u003ch3\u003eHow much runtime does this unit provide during an outage?\u003c\/h3\u003e\u003cp\u003eAt full rated load of 1350W, expect approximately 5.8 minutes of runtime; at half load, runtime extends to about 16 minutes.\u003c\/p\u003e\u003ch3\u003eWhat is the warranty coverage?\u003c\/h3\u003e\u003cp\u003eEaton provides a 2-year limited warranty along with $250,000 in Connected Equipment Insurance for US and Canada.\u003c\/p\u003e\u003ch3\u003eCan runtime be extended for longer outages?\u003c\/h3\u003e\u003cp\u003eYes, the unit supports up to four optional BP48RT battery modules for extended backup time.\u003c\/p\u003e\u003ch3\u003eDoes this UPS support remote monitoring integration?\u003c\/h3\u003e\u003cp\u003eYes, it includes USB, RS-232, dry-contact relay, and RPO\/ROO ports, with an optional SNMP card slot for network-based monitoring.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":48159973441772,"sku":"SUINT1500LCD2U","price":1460.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/suint1500lcd2u.jpg?v=1786678631","url":"https:\/\/creationnetworks.net\/products\/eaton-suint1500lcd2u-ups-1500va-1350w-intl-smart-online-lcd-usb-db9-208-230v-2urm","provider":"Creation Networks","version":"1.0","type":"link"}