{"product_id":"eaton-su750rtxlcd2un-smartonline-120v-750va-675w-double-conversion-ups-2u-rack-tower-6-outlets-extended-run","title":"Eaton SU750RTXLCD2UN – 750VA Double-Conversion Rack UPS","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe Eaton SU750RTXLCD2UN is a 750VA\/675W online double-conversion UPS 2U rack-mount unit built for AV racks and network equipment rooms that require true isolation from utility power problems. Its constant on-line operation makes it a reliable double-conversion UPS for conference room installations, digital signage controllers, and networking gear where zero transfer time to battery is required to avoid reboots or dropped sessions. With a front-panel LCD, extended runtime capability, and a pre-installed WEBCARDLXE network card, this unit fits well into a commercial UPS battery backup installation supporting mission-critical AV and IT loads.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/su750rtxlcd2un.jpg?v=1786678630\" alt=\"Eaton SU750RTXLCD2UN 2U double-conversion rack UPS\" style=\"max-width:100%;height:auto;\"\u003e\u003cp\u003eUnlike line-interactive designs that briefly switch to battery during a power event, the SU750RTXLCD2UN continuously converts incoming AC to DC and back to a clean, regulated sine wave AC output, fully isolating connected equipment from blackouts, brownouts, surges, and line noise. This zero transfer time UPS for network equipment is well suited to conference room AV racks, huddle room video bars, and boardroom control processors where even a momentary interruption can disrupt a meeting or reset a device. The 2U rack\/tower chassis includes eight 5-15R outlets delivering true sine wave, filtered output, and supports up to four external battery modules (BP36RT) for facilities that need extended runtime beyond the internal battery. The interactive LCD interface reports operating mode, load, and site-power data directly on the front panel, simplifying diagnostics for AV integrators during commissioning and service calls. A pre-installed WEBCARDLXE network card with USB and RS-232 connectivity enables remote monitoring, which is valuable for IT and facilities teams managing UPS fleets across multiple conference rooms or training rooms. This LCD display rack-mount UPS is a practical choice anywhere constant on-line protection and extended runtime options matter more than cost alone.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOnline Double-Conversion Topology\u003c\/strong\u003e — Provides zero transfer time to battery, fully isolating equipment from AC line disturbances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e750VA\/675W Capacity\u003c\/strong\u003e — Sized for AV control processors, network switches, and conferencing equipment in a rack or credenza.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEight 5-15R Outlets\u003c\/strong\u003e — Delivers filtered, true sine wave power to multiple connected devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInteractive Front-Panel LCD\u003c\/strong\u003e — Displays operating mode, load level, and site-power data for on-site diagnostics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended Run Support\u003c\/strong\u003e — Compatible with up to four BP36RT external battery modules for longer outage coverage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-Installed WEBCARDLXE Network Card\u003c\/strong\u003e — Enables remote monitoring and management over USB, RS-232, and network connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-Swappable VRLA Battery\u003c\/strong\u003e — Allows field battery replacement without powering down connected equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2U Rack\/Tower Form Factor\u003c\/strong\u003e — Fits standard 19-inch racks or can be deployed as a freestanding tower.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConference room\u003c\/li\u003e\n\u003cli\u003eBoardroom\u003c\/li\u003e\n\u003cli\u003eHuddle room\u003c\/li\u003e\n\u003cli\u003eTraining room\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;min-width:480px;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;border-bottom:1px solid #ccc;padding:6px;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"text-align:left;border-bottom:1px solid #ccc;padding:6px;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003ePower Rating\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e750VA \/ 675W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e120V nominal (confirm exact input range against manufacturer spec sheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e120V nominal (confirm exact output range and regulation against manufacturer spec sheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eOutlets\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e8x 5-15R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eRuntime (Full Load)\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e7.9 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eRuntime (Half Load)\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e20.9 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e3.41\" H x 17.33\" W x 17.72\" D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e36.38 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eExtended Runtime\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eUp to 4 external battery modules (BP36RT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eNetwork Card\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003ePre-installed WEBCARDLXE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e2-year limited\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eIs this UPS compatible with a standard 19-inch conference room AV rack?\u003c\/h3\u003e\u003cp\u003eYes, the SU750RTXLCD2UN ships in a 2U rack\/tower chassis designed to mount in a standard 19-inch AV or IT rack, or to be used freestanding.\u003c\/p\u003e\u003ch3\u003eDoes this UPS reboot connected equipment during a power outage?\u003c\/h3\u003e\u003cp\u003eNo, its online double-conversion design provides zero transfer time between line and battery power, so connected AV and network equipment stays running without a reboot.\u003c\/p\u003e\u003ch3\u003eCan runtime be extended beyond the internal battery?\u003c\/h3\u003e\u003cp\u003eYes, the unit supports up to four BP36RT external battery modules for facilities that need longer runtime coverage during extended outages.\u003c\/p\u003e\u003ch3\u003eWhat remote monitoring options are included?\u003c\/h3\u003e\u003cp\u003eA WEBCARDLXE network card is pre-installed, providing remote monitoring and management alongside USB and RS-232 connectivity.\u003c\/p\u003e\u003ch3\u003eWhat is the manufacturer warranty on this unit?\u003c\/h3\u003e\u003cp\u003eEaton backs the SU750RTXLCD2UN with a 2-year limited warranty.\u003c\/p\u003e\u003ch3\u003eCan the battery be replaced without shutting down connected AV equipment?\u003c\/h3\u003e\u003cp\u003eYes, the internal VRLA battery is field-replaceable and hot-swappable, allowing service without powering down connected loads.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":48159973081324,"sku":"SU750RTXLCD2UN","price":1434.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/su750rtxlcd2un.jpg?v=1786678629","url":"https:\/\/creationnetworks.net\/products\/eaton-su750rtxlcd2un-smartonline-120v-750va-675w-double-conversion-ups-2u-rack-tower-6-outlets-extended-run","provider":"Creation Networks","version":"1.0","type":"link"}