{"product_id":"eaton-su3000rtxlcd2un-smartonline-120v-3000va-2700w-double-conversion-ups-9-outlets","title":"Eaton SU3000RTXLCD2UN – 3000VA Online UPS, 9 Outlets","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Eaton SU3000RTXLCD2UN is a 3000VA\/2700W SmartOnline double-conversion UPS built for AV equipment rooms, broadcast racks, and server closets that need substantial, continuously conditioned backup power. As a 2U rack-mount UPS with LCD display, it fits standard equipment racks and gives installers 9 total outlets to power matrix switchers, amplifiers, network switches, and control processors from a single unit. Zero transfer time between line and battery modes makes it a strong fit for commercial UPS battery backup installation in boardrooms, auditoriums, and broadcast studios where even momentary power interruption is unacceptable. Optional network management hardware extends remote monitoring to facilities teams overseeing multiple AV racks.\u003c\/p\u003e\n\n\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/su3000rtxlcd2un.jpg?v=1786678669\" alt=\"Eaton SU3000RTXLCD2UN 3000VA online UPS\" style=\"max-width:100%;height:auto;\"\u003e\n\u003cp\u003eThis on-line double-conversion UPS system maintains perfect output quality by converting incoming AC input to DC and then reconverting it to fully regulated sine wave AC, completely isolating connected AV and IT equipment from every power problem on the incoming line. Constant on-line operation means there is zero transfer time between on-line and battery modes, which is critical for broadcast studios, auditoriums, and boardrooms running live AV signal processing that cannot tolerate even a brief power gap. At 3000VA\/2700W, the unit has the capacity to run a rack of amplifiers, matrix switchers, and network gear simultaneously, and its 9-outlet configuration reduces the need for secondary power strips inside the rack. The 2U rack-mount UPS with LCD display shows real-time load, input, and battery status directly on the front panel, giving AV technicians a fast way to verify system health during routine rack checks. ±1% output regulation in line mode and ±2% in battery mode keeps voltage tightly controlled for sensitive AV processing equipment, and the unit supports an optional WEBCARDLXE network management card for remote SNMP\/HTTP monitoring across multiple rack locations. This model is a practical choice for AV integrators specifying a rack-mount UPS for AV equipment room installations in commercial meeting spaces, government facilities, or training rooms where reliable, always-on power is a design requirement.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3000VA\/2700W Capacity\u003c\/strong\u003e — Supports a full rack of AV amplifiers, switchers, and network equipment from a single UPS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero Transfer Time\u003c\/strong\u003e — Online double-conversion topology eliminates any gap between line power and battery power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e9 Total Outlets\u003c\/strong\u003e — Reduces the need for secondary power strips inside a crowded AV or server rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2U Rack-Mount Design\u003c\/strong\u003e — Fits directly into standard 19-inch AV and IT equipment racks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFront-Panel LCD Display\u003c\/strong\u003e — Shows real-time load, input voltage, and battery status for quick on-site diagnostics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTight Voltage Regulation\u003c\/strong\u003e — ±1% output regulation in line mode protects sensitive AV processing equipment from voltage fluctuation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Network Management Card\u003c\/strong\u003e — Supports the WEBCARDLXE card for remote monitoring of multiple AV rack locations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBroadcast studio racks requiring zero-transfer-time backup power for live signal processing\u003c\/li\u003e\n\u003cli\u003eBoardroom AV racks with high-capacity amplifier and switching equipment\u003c\/li\u003e\n\u003cli\u003eAuditorium AV systems needing sustained power for a full rack of processing gear\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space installations with centralized AV\/IT power requirements\u003c\/li\u003e\n\u003cli\u003eTraining room AV racks requiring reliable backup power for control systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;min-width:480px;\"\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity\u003c\/td\u003e\n\u003ctd\u003e3000 VA \/ 2700 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eOnline double-conversion (SmartOnline)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e100\/110\/120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Regulation\u003c\/td\u003e\n\u003ctd\u003e±1% (line mode), ±2% (battery mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlets\u003c\/td\u003e\n\u003ctd\u003e9 total outlets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRuntime at Full Load (2700W)\u003c\/td\u003e\n\u003ctd\u003e4.8 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRuntime at Half Load\u003c\/td\u003e\n\u003ctd\u003e13.9 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003e2U rackmount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (D x W x H)\u003c\/td\u003e\n\u003ctd\u003e23.82 in x 17.33 in x 3.41 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e63.06 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Management\u003c\/td\u003e\n\u003ctd\u003eOptional WEBCARDLXE card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-year limited warranty (worldwide)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eCan the SU3000RTXLCD2UN power an entire AV rack, including amplifiers?\u003c\/h3\u003e\n\u003cp\u003eYes, provided the combined connected load of all AV and network equipment stays within 2700W. Calculate total rack wattage before finalizing your design.\u003c\/p\u003e\n\u003ch3\u003eDoes this UPS support remote monitoring across multiple rooms?\u003c\/h3\u003e\n\u003cp\u003eYes, with the optional WEBCARDLXE network management card, which enables SNMP\/HTTP monitoring for facilities managing several AV racks.\u003c\/p\u003e\n\u003ch3\u003eIs there any power gap when switching from utility power to battery?\u003c\/h3\u003e\n\u003cp\u003eNo. The online double-conversion design provides zero transfer time between line and battery modes, which is important for broadcast and live-event AV systems.\u003c\/p\u003e\n\u003ch3\u003eHow many outlets are available for connected equipment?\u003c\/h3\u003e\n\u003cp\u003eThe unit provides 9 total outlets, reducing the need for a secondary power strip inside the rack.\u003c\/p\u003e\n\u003ch3\u003eWhat is the expected runtime during an outage?\u003c\/h3\u003e\n\u003cp\u003eRuntime is 4.8 minutes at full 2700W load and 13.9 minutes at half load, per manufacturer testing.\u003c\/p\u003e\n\u003ch3\u003eWhat warranty coverage applies to this UPS?\u003c\/h3\u003e\n\u003cp\u003eEaton provides a 2-year limited worldwide warranty on the SU3000RTXLCD2UN.\u003c\/p\u003e\n\u003ch3\u003eCan Creation Networks assist with rack layout and load planning for this UPS?\u003c\/h3\u003e\n\u003cp\u003eYes. Contact Creation Networks for help calculating AV rack load and confirming this UPS meets your runtime requirements.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":48159974228204,"sku":"SU3000RTXLCD2UN","price":3433.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/su3000rtxlcd2un.jpg?v=1786678669","url":"https:\/\/creationnetworks.net\/products\/eaton-su3000rtxlcd2un-smartonline-120v-3000va-2700w-double-conversion-ups-9-outlets","provider":"Creation Networks","version":"1.0","type":"link"}