{"product_id":"eaton-su1000rtxlcd2un-smartonline-120v-1000va-900w-double-conversion-ups-6-outlets-extended","title":"Eaton SU1000RTXLCD2UN – 1000VA Rack UPS, Extended Run","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe Eaton SU1000RTXLCD2UN is a 1000VA\/900W online double-conversion UPS built for AV racks and data closets that require zero-transfer-time protection with extended-run flexibility. As an extended-run rack UPS supporting online double-conversion UPS for data closet deployments, it fits commercial UPS battery backup installation projects where connected control processors, switches, and network gear cannot tolerate a power transfer gap. The 2U rack\/tower unit includes six outlets, an LCD display, and support for extended battery packs when longer runtime is needed.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/su1000rtxlcd2un.jpg?v=1786678609\" alt=\"Eaton SU1000RTXLCD2UN online double-conversion rack UPS\" style=\"max-width:100%;height:auto;\"\u003e\u003cp\u003eThe SU1000RTXLCD2UN supplies 1000VA\/900W of true sine wave power through online double-conversion topology, continuously regenerating output so connected equipment never experiences a transfer delay during a utility event. This makes it a dependable extended-run rack UPS for protecting AV control processors, network switches, and other equipment sensitive to even brief power interruptions. It accepts 100\/110\/120 VAC input with tightly regulated output, helping stabilize power quality feeding a rack in a commercial building with variable utility conditions. The 2U rack\/tower chassis includes both rack rails and tower stands, and its design supports extended-run battery packs for facilities that need runtime beyond the standard internal battery, useful for online double-conversion UPS for data closet applications without an on-site generator. Six 5-15R outlets provide sufficient capacity for a small-to-moderate rack of AV and network devices, and the menu-driven LCD display reports load, input\/output voltage, and battery status directly on the unit. This model also supports the WEBCARDLXE network card as an accessory for SNMP-based remote monitoring, allowing facilities and IT staff to track its status alongside other UPS units on the network. For commercial UPS battery backup installation where extended ride-through time is a design requirement, the SU1000RTXLCD2UN pairs double-conversion reliability with the flexibility to scale runtime as needed.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOnline Double-Conversion Topology\u003c\/strong\u003e — It continuously regenerates output power for zero transfer time, protecting sensitive AV and network equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1000VA\/900W Capacity\u003c\/strong\u003e — It is sized for a small-to-moderate rack of AV and network devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2U Rack\/Tower Convertible Chassis\u003c\/strong\u003e — It includes rack rails and tower stands for flexible installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended-Run Battery Support\u003c\/strong\u003e — It is compatible with external battery packs for longer runtime in facilities without backup generation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue Sine Wave Output\u003c\/strong\u003e — It delivers clean power quality matched to utility-grade waveforms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLCD Status Display\u003c\/strong\u003e — It reports load, voltage, and battery status directly on the unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Card Support\u003c\/strong\u003e — It is compatible with the WEBCARDLXE card for SNMP-based remote monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConference room AV racks needing extended ride-through during outages\u003c\/li\u003e\n\u003cli\u003eTraining room and multi-purpose room equipment closets supporting network and control gear\u003c\/li\u003e\n\u003cli\u003eGovernment space data closets requiring uninterrupted power for connected systems\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;min-width:480px;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;border-bottom:1px solid #ccc;padding:6px;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"text-align:left;border-bottom:1px solid #ccc;padding:6px;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eCapacity\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e1000VA \/ 900W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eTopology\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eOnline double-conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e100\/110\/120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e120V default (100\/110\/120\/125V selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eOutlets\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e8 x 5-15R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eRuntime (full load \/ half load)\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e6.3 min \/ 18.2 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eBattery Type\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eValve Regulated Lead Acid (VRLA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e3.41 in x 17.33 in x 17.72 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e36.38 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e2U rack\/tower convertible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e2-year limited (5-year extended plans available)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eCan this UPS be expanded with additional battery capacity?\u003c\/h3\u003e\u003cp\u003eYes. The SU1000RTXLCD2UN supports extended-run battery packs for facilities that need more ride-through time than the internal battery provides.\u003c\/p\u003e\u003ch3\u003eIs this unit compatible with network monitoring systems?\u003c\/h3\u003e\u003cp\u003eYes, it supports the WEBCARDLXE network card accessory for SNMP-based remote monitoring across a facility network.\u003c\/p\u003e\u003ch3\u003eWhat makes double-conversion topology preferable for AV racks?\u003c\/h3\u003e\u003cp\u003eBecause output power is continuously regenerated rather than switched, connected AV and network equipment experiences no transfer delay during a utility failure, unlike line-interactive designs.\u003c\/p\u003e\u003ch3\u003eDoes this unit fit in a standard rack, or does it require a tower installation?\u003c\/h3\u003e\u003cp\u003eIt ships as a 2U rack\/tower convertible unit, so it can be installed in a standard 19-inch rack or used as a standalone tower.\u003c\/p\u003e\u003ch3\u003eWhat warranty coverage is included?\u003c\/h3\u003e\u003cp\u003eThe unit carries a 2-year limited warranty, with 5-year extended service plans available separately.\u003c\/p\u003e\u003ch3\u003eCan Creation Networks help determine if extended battery packs are needed for our installation?\u003c\/h3\u003e\u003cp\u003eYes, contact our team with your required runtime and connected load, and we can recommend whether extended-run battery packs are appropriate for your deployment.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":48159972458732,"sku":"SU1000RTXLCD2UN","price":1666.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/su1000rtxlcd2un.jpg?v=1786678609","url":"https:\/\/creationnetworks.net\/products\/eaton-su1000rtxlcd2un-smartonline-120v-1000va-900w-double-conversion-ups-6-outlets-extended","provider":"Creation Networks","version":"1.0","type":"link"}