{"product_id":"eaton-smart750rmxl2u-750va-ups-system-smartpro-rack-tower-extended-run-line-interactive-120v","title":"Eaton SMART750RMXL2U – 750VA 120V Rack UPS Extended Run","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe Eaton SMART750RMXL2U is a 750VA\/750W, 120V line-interactive rack UPS built for network equipment, AV racks, and telecommunications closets that demand consistent, clean power. As a 750VA rack UPS for network equipment with built-in Automatic Voltage Regulation, it corrects brownouts and overvoltages instantly without switching to battery, making it well suited as a line-interactive UPS for AV rack deployments in commercial spaces. This commercial UPS battery backup installation option pairs an interactive LCD display with millisecond-fast transfer to keep servers, switches, and control processors running through short outages.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/smart750rmxl2u.jpg?v=1786678631\" alt=\"Eaton SMART750RMXL2U 750VA rack UPS\" style=\"max-width:100%;height:auto;\"\u003e\u003cp\u003eHoused in a 2U rack-mount UPS with AVR chassis (also usable as a tower), the SMART750RMXL2U fits directly into standard 19-inch AV and IT racks alongside switches, media converters, and control system processors. Its interactive LCD interface reports operating mode, load level, battery status, and site power quality directly on the unit, giving technicians the information they need without connecting a laptop. Automatic Voltage Regulation actively corrects under- and over-voltage conditions back to usable levels while keeping the battery fully charged, reducing wear on the battery and extending its service life. Switchover from utility to battery power occurs in milliseconds, fast enough to keep connected equipment running without a reboot. Eight 5-15R outlets provide ample connection points for a small AV rack or network closet stack, and the unit supports optional extended battery modules for longer runtime in critical applications. With 95% line-mode efficiency, it also runs cooler and more efficiently than older transformer-based designs, which matters in enclosed AV racks and data closets with limited airflow. This extended run UPS for network closet use includes USB, DB9 serial, and network card slot options for integration with building monitoring and automated shutdown software.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic Voltage Regulation (AVR)\u003c\/strong\u003e — Corrects brownouts and overvoltages in real time, preserving battery charge and extending battery life.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInteractive LCD Display\u003c\/strong\u003e — Reports UPS operating mode, load, and site power data directly on the front panel for fast diagnostics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMillisecond Transfer Time\u003c\/strong\u003e — Switches to battery power within 4 milliseconds to prevent reboots of connected equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2U Rack\/Tower Form Factor\u003c\/strong\u003e — Mounts in standard AV or IT racks or stands independently as a tower unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEight 5-15R Outlets\u003c\/strong\u003e — Powers a full small rack stack of network, AV, or telecom equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-Swappable Batteries\u003c\/strong\u003e — Allows battery replacement without powering down connected equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpandable Runtime\u003c\/strong\u003e — Supports up to four optional extended battery modules for longer backup time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e95% Line-Mode Efficiency\u003c\/strong\u003e — Reduces heat output and operating costs in enclosed rack environments.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConference room AV racks requiring backup power for switchers and processors\u003c\/li\u003e\n\u003cli\u003eBoardroom and huddle room AV equipment closets\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space network racks\u003c\/li\u003e\n\u003cli\u003eTraining room AV distribution systems\u003c\/li\u003e\n\u003cli\u003eMulti-purpose room AV racks\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;min-width:480px;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;border:1px solid #ccc;padding:6px;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"text-align:left;border:1px solid #ccc;padding:6px;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eCapacity\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003e750VA \/ 750W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003e120V AC (80V–151V range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003ePower Factor\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003e1 (unity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eOutlets\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eEight 5-15R, pure sine wave output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eRuntime at Full Load\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003e9 minutes (750W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eRuntime at Half Load\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003e23 minutes (375W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eRecharge Time\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eLess than 4.5 hours (10-90%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eBattery Type\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eValve Regulated Lead Acid (VRLA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003e2U rack\/tower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003e3.45 in x 17.2 in x 17.6 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eUnit Weight\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003e44.5 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003e2-year warranty, 3 years with registration; $250,000 Connected Equipment Insurance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWill this UPS fit in a standard AV or network rack?\u003c\/h3\u003e\u003cp\u003eYes, the SMART750RMXL2U ships in a 2U rack\/tower configuration with mounting hardware for standard 19-inch racks, and it can also be used as a freestanding tower unit.\u003c\/p\u003e\u003ch3\u003eHow fast does it switch to battery power during an outage?\u003c\/h3\u003e\u003cp\u003eTransfer from utility to battery power occurs within approximately 4 milliseconds, fast enough to keep most network and AV equipment running without interruption or reboot.\u003c\/p\u003e\u003ch3\u003eCan the battery be replaced without shutting down connected equipment?\u003c\/h3\u003e\u003cp\u003eYes, the batteries are hot-swappable, allowing replacement while connected devices remain powered.\u003c\/p\u003e\u003ch3\u003eCan I extend the runtime beyond the standard battery?\u003c\/h3\u003e\u003cp\u003eYes, the unit supports up to four optional extended battery modules for applications requiring longer backup time.\u003c\/p\u003e\u003ch3\u003eWhat is the warranty on this unit?\u003c\/h3\u003e\u003cp\u003eEaton provides a 2-year warranty, extendable to 3 years with product registration, along with $250,000 in Connected Equipment Insurance.\u003c\/p\u003e\u003ch3\u003eDoes this UPS support remote monitoring for a network operations center?\u003c\/h3\u003e\u003cp\u003eYes, it offers an optional network management card slot in addition to USB and DB9 serial ports for integration with monitoring and automated shutdown software.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":48159973343468,"sku":"SMART750RMXL2U","price":906.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/smart750rmxl2u.jpg?v=1786678631","url":"https:\/\/creationnetworks.net\/products\/eaton-smart750rmxl2u-750va-ups-system-smartpro-rack-tower-extended-run-line-interactive-120v","provider":"Creation Networks","version":"1.0","type":"link"}