{"product_id":"eaton-smart750rm1u-750va-600w-ups-smart-rackmount-avr-120v-usb-db9-snmp-1urm","title":"Eaton SMART750RM1U – 750VA 1U Rack-Mount UPS","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe Eaton SMART750RM1U is a 750VA\/600W line-interactive sine wave UPS purpose-built as a 1U rack-mount UPS for AV racks, network closets, and computer rooms. It provides line-interactive voltage regulation, network-grade surge suppression, and sine wave AC output during blackouts to protect AV control processors, network switches, and codecs. This rack-mount UPS for conference room AV rack installations fits into a single rack unit alongside switchers and network gear, and its optional SNMP\/Web card enables remote monitoring for facilities and IT teams managing multiple rooms.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/smart750rm1u.jpg?v=1786678649\" alt=\"Eaton SMART750RM1U 1U rack-mount UPS\" style=\"max-width:100%;height:auto;\"\u003e\u003cp\u003eThe SMART750RM1U packs 750VA\/600W of line-interactive power protection into a highly efficient 1U total rack\/tower configuration, making it one of the more space-efficient options for a network closet or AV equipment rack where every rack unit counts. Line-interactive voltage regulation corrects input voltage from 83V to 147V back to a usable 110\/120V output without switching to battery, extending runtime for genuine outages. The unit provides six NEMA 5-15R outlets with 450 joules of surge protection, split into two independently switchable outlet banks so integrators can sequence non-critical loads separately from critical AV or network equipment. Simultaneous-use network management interfaces — USB, RS-232 (DB9), and an optional SNMP\/Web accessory card — give AV control systems and IT monitoring platforms multiple ways to poll UPS status and trigger automated shutdown sequences. This 1U UPS battery backup for network closet and rack applications runs at 98% line-mode efficiency, keeping operating costs down for always-on commercial deployments. Its low-profile design fits standard 2-post and 4-post racks, making it a practical choice for conference room AV racks, data closets, and multi-purpose room equipment enclosures where a full-size tower UPS would take up too much rack space.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1U rackmount form factor\u003c\/strong\u003e — Delivers 750VA\/600W of protection while occupying just a single rack unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine-interactive voltage regulation\u003c\/strong\u003e — Corrects 83V to 147V input back to usable 110\/120V output without draining the battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSix switchable outlets\u003c\/strong\u003e — Two independently controlled outlet banks let integrators sequence critical and non-critical AV\/network loads separately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e450 joules of surge suppression\u003c\/strong\u003e — Protects connected AV and networking equipment from transient voltage spikes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultiple monitoring interfaces\u003c\/strong\u003e — USB, RS-232 (DB9), and optional SNMP\/Web card support remote status polling and automated shutdown.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSine wave output\u003c\/strong\u003e — Provides clean power compatible with active PFC power supplies common in modern AV and IT equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e98% line-mode efficiency\u003c\/strong\u003e — Reduces operating cost for continuously powered commercial installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-year warranty, extendable to 3 years\u003c\/strong\u003e — Provides standard worldwide coverage that extends to three years when the product is registered.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConference room AV equipment racks\u003c\/li\u003e\n\u003cli\u003eHuddle room network and control equipment\u003c\/li\u003e\n\u003cli\u003eTraining room AV racks\u003c\/li\u003e\n\u003cli\u003eMulti-purpose room equipment closets\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space data\/network racks\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;min-width:480px;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;border-bottom:1px solid #ccc;padding:6px;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"text-align:left;border-bottom:1px solid #ccc;padding:6px;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eCapacity\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e750 VA \/ 600 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eInput voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eOutput voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e110\/120V nominal, corrects 83V-147V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eOutlets\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e6 x NEMA 5-15R, 450 joules surge protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eRuntime (full load, 600W)\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e4.9 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eRuntime (half load)\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e13 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e17.5 in x 1.75 in x 16.75 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e30 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eRack height\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eEfficiency\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e98% line-mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eMonitoring ports\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eUSB, RS-232 (DB9), optional SNMP\/Web card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e2 years worldwide (3 years with registration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWill the SMART750RM1U fit a standard 2-post or 4-post AV rack?\u003c\/h3\u003e\u003cp\u003eYes, the unit is designed to fit both 2-post and 4-post rack installations in a single 1U space.\u003c\/p\u003e\u003ch3\u003eCan I connect this UPS to an AV control system for automated shutdown?\u003c\/h3\u003e\u003cp\u003eYes, the USB and RS-232 (DB9) ports allow AV control processors or monitoring software to poll UPS status and trigger scripted shutdown sequences.\u003c\/p\u003e\u003ch3\u003eIs remote monitoring available for multi-room deployments?\u003c\/h3\u003e\u003cp\u003eAn optional SNMP\/Web accessory card can be added to enable network-based remote monitoring, useful for facilities managing UPS units across several conference or training rooms.\u003c\/p\u003e\u003ch3\u003eWhat is the benefit of the two switchable outlet banks?\u003c\/h3\u003e\u003cp\u003eThe two independently switchable outlet banks let integrators power-cycle or sequence non-critical loads separately from equipment that must stay running continuously.\u003c\/p\u003e\u003ch3\u003eHow long is the warranty and can it be extended?\u003c\/h3\u003e\u003cp\u003eThe standard warranty is 2 years worldwide, extendable to 3 years with product registration.\u003c\/p\u003e\u003ch3\u003eDoes this UPS support sine wave output for AV amplifiers?\u003c\/h3\u003e\u003cp\u003eYes, the SMART750RM1U produces sine wave AC output during battery operation, which is compatible with AV amplifiers and equipment requiring clean power.\u003c\/p\u003e\u003ch3\u003eWhat support does Creation Networks provide after installation?\u003c\/h3\u003e\u003cp\u003eContact Creation Networks for installation guidance, compatible accessory cards, and manufacturer warranty registration assistance for your commercial AV rack deployment.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":48159973638380,"sku":"SMART750RM1U","price":804.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/smart750rm1u.jpg?v=1786678649","url":"https:\/\/creationnetworks.net\/products\/eaton-smart750rm1u-750va-600w-ups-smart-rackmount-avr-120v-usb-db9-snmp-1urm","provider":"Creation Networks","version":"1.0","type":"link"}