{"product_id":"eaton-smart5000xfmrxl-smartpro-208-120v-5kva-3-75kw-line-interactive-sine-wave-ups-3u-ext-rn","title":"Eaton SMART5000XFMRXL – 5kVA 3U Extended-Run Sine Wave UPS","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe Eaton SMART5000XFMRXL is an extended-run 5kVA UPS for AV rack and broadcast installations that require simultaneous 208V and 120V output from a single 3U enclosure. This 208\/120V dual output UPS for AV systems is built for server, network, and telecommunications equipment where a mix of high-current and standard-voltage loads share the same rack. As a 3U rackmount UPS for broadcast equipment, it delivers full sine wave output and expandable runtime for commercial UPS battery backup installation projects where downtime carries a high operational cost.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/smart5000xfmrxl.jpg?v=1786678477\" alt=\"Eaton SMART5000XFMRXL 5kVA 3U extended-run UPS\" style=\"max-width:100%;height:auto;\"\u003e\u003cp\u003eThe SMART5000XFMRXL is a line-interactive UPS rated for 5000VA\/3.75kW, accepting 208V nominal input and delivering simultaneous 208V and 120V output through eleven total receptacles. Eight switchable 5-15\/20R outlets serve standard 120V AV and IT equipment, while two L6-20R and one L6-30R receptacle handle higher-current 208V loads, letting a single UPS support a mixed broadcast or data rack without a separate step-down transformer. Sine wave output maintains battery-derived power during blackouts and severe voltage fluctuations, correcting brownouts and overvoltages from 167V to 260V without drawing on the battery. The unit's extended-run design supports optional external battery packs, allowing facilities to scale runtime well beyond the internal battery capacity as load and outage-duration requirements grow. A NEMA L6-30P input connection supports either a user-supplied 30A circuit or hardwired input, and network-grade AC surge and noise suppression protects connected equipment on the incoming feed. Network management interfaces include USB, DB9 serial, and an SNMPWEBCARD slot, giving facilities teams remote visibility into a high-capacity power system supporting broadcast studio equipment, government facility racks, or large commercial AV deployments.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSimultaneous 208V and 120V Output\u003c\/strong\u003e — Powers mixed-voltage equipment from a single UPS without a separate transformer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEleven Output Receptacles\u003c\/strong\u003e — Eight switchable 5-15\/20R outlets plus two L6-20R and one L6-30R support diverse rack equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSine Wave Output\u003c\/strong\u003e — Maintains clean, battery-derived AC power during blackouts and severe voltage fluctuations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpandable Runtime\u003c\/strong\u003e — Supports optional external battery packs to scale backup time beyond the internal battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork-Grade Surge and Noise Suppression\u003c\/strong\u003e — Provides 1020 joules of surge protection on the incoming AC feed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSNMPWEBCARD Slot\u003c\/strong\u003e — Accepts an optional network management card for centralized remote monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSB and DB9 Monitoring Ports\u003c\/strong\u003e — Support unattended shutdown software for unattended equipment rooms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact 3U Footprint\u003c\/strong\u003e — Delivers 5kVA-class capacity in only 3 rack units of a standard 19-inch rack.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBroadcast studio racks requiring simultaneous 208V and 120V power protection\u003c\/li\u003e\n\u003cli\u003eGovernment space equipment rooms with high-capacity, mission-critical loads\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space AV racks combining servers, switches, and control systems\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;min-width:480px;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;border:1px solid #ccc;padding:8px;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"text-align:left;border:1px solid #ccc;padding:8px;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:8px;\"\u003eCapacity\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:8px;\"\u003e5000VA \/ 3.75kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:8px;\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:8px;\"\u003e3U rack\/tower, extended run\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:8px;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:8px;\"\u003e5.25 in x 17.5 in x 25 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:8px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:8px;\"\u003e143.3 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:8px;\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:8px;\"\u003e208V AC nominal, single-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:8px;\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:8px;\"\u003eSimultaneous 208V and 120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:8px;\"\u003eInput Connector\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:8px;\"\u003eNEMA L6-30P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:8px;\"\u003eOutlets\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:8px;\"\u003e8x 5-15\/20R, 2x L6-20R, 1x L6-30R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:8px;\"\u003eRuntime (Full Load)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:8px;\"\u003e8.5 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:8px;\"\u003eRuntime (Half Load)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:8px;\"\u003e20 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:8px;\"\u003eBattery Type\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:8px;\"\u003eVRLA (RBC94-3U replacement)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:8px;\"\u003eSurge Protection\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:8px;\"\u003e1020 joules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:8px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:8px;\"\u003e2 years standard, 3 years with registration, $250,000 Ultimate Lifetime Insurance (US\/Canada\/Puerto Rico)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eCan this UPS power both 208V and 120V equipment at the same time?\u003c\/h3\u003e\u003cp\u003eYes. The SMART5000XFMRXL provides simultaneous 208V and 120V output across eleven receptacles, allowing mixed-voltage equipment to run from a single unit.\u003c\/p\u003e\u003ch3\u003eHow is runtime extended beyond the internal battery?\u003c\/h3\u003e\u003cp\u003eThe unit supports optional external battery packs, allowing facilities to add runtime as load or outage-duration requirements increase.\u003c\/p\u003e\u003ch3\u003eWhat remote monitoring options does this UPS support?\u003c\/h3\u003e\u003cp\u003eIt includes an SNMPWEBCARD slot for an optional network management card, plus built-in USB and DB9 serial ports for unattended shutdown integration.\u003c\/p\u003e\u003ch3\u003eWhat input connection does this UPS require?\u003c\/h3\u003e\u003cp\u003eIt uses a NEMA L6-30P plug and requires a dedicated 208V, 30A circuit, or can be hardwired by a licensed electrician.\u003c\/p\u003e\u003ch3\u003eIs this UPS suitable for broadcast studio installations?\u003c\/h3\u003e\u003cp\u003eYes. Its combination of high capacity, dual-voltage output, and expandable runtime makes it well suited for broadcast studio racks and other high-demand commercial AV environments.\u003c\/p\u003e\u003ch3\u003eWhat is the warranty on this UPS?\u003c\/h3\u003e\u003cp\u003eStandard coverage is 2 years, extendable to 3 years with product registration, and includes $250,000 Ultimate Lifetime Insurance coverage in the US, Canada, and Puerto Rico. Contact Creation Networks for warranty assistance.\u003c\/p\u003e\u003ch3\u003eCan the internal batteries be serviced without powering down the connected rack?\u003c\/h3\u003e\u003cp\u003eThe internal VRLA batteries are replaceable; contact Creation Networks to confirm hot-swap procedures and compatible replacement battery part numbers for your installation.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":48159972131052,"sku":"SMART5000XFMRXL","price":4920.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/smart5000xfmrxl.jpg?v=1786678477","url":"https:\/\/creationnetworks.net\/products\/eaton-smart5000xfmrxl-smartpro-208-120v-5kva-3-75kw-line-interactive-sine-wave-ups-3u-ext-rn","provider":"Creation Networks","version":"1.0","type":"link"}