{"product_id":"eaton-smart2200rmxl2u-2200va-ups-system-smartpro-rack-tower-line-interactive-120v-8-outlet","title":"Eaton SMART2200RMXL2U – 2200VA Rack-Mount UPS for AV Racks","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe Eaton SMART2200RMXL2U is a 2200VA\/1920W line-interactive UPS designed as a rack-mount UPS for AV rack deployments protecting servers, network switches, matrix switchers, and control processors. It is a solid choice for a commercial UPS battery backup installation in a conference room AV rack, broadcast equipment rack, or data closet where uptime for network-attached devices is critical. Built-in AVR corrects brownouts and overvoltages without switching to battery, and dual switched load banks let integrators schedule remote reboots of non-critical equipment. At 2U, it fits standard 19-inch rack enclosures without consuming excessive rack space that could otherwise house AV processing gear.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/smart2200rmxl2u.jpg?v=1786678433\" alt=\"Eaton SMART2200RMXL2U 2200VA rack-mount UPS\" style=\"max-width:100%;height:auto;\"\u003e\u003cp\u003eThe SMART2200RMXL2U is built for network-grade power protection in commercial AV and IT racks, combining line-interactive AVR with an interactive LCD interface that reports UPS operating mode, site power quality, and configuration options directly at the rack. As a rack-mount UPS for AV rack installations, it protects control processors, network switches, matrix switchers, and streaming encoders commonly found in conference room and broadcast equipment racks. Two independent levels of voltage boost correct both slight undervoltages and severe brownouts, which matters in older commercial buildings with inconsistent utility power. Switchover from line to battery power occurs within milliseconds, keeping connected AV and network equipment running without interruption or reboot during short outages. Communication options include USB, RS-232, and a slot for an optional network management card, supporting a network management UPS with SNMP card deployment for facilities that monitor power infrastructure centrally. Two independently switched load banks let facilities staff perform scheduled or remote reboots and shed non-critical loads without physically accessing the rack. The LCD panel rotates for readability in both rack-mount and tower orientation, useful when the same model is deployed across different room configurations. Field-replaceable, hot-swappable battery modules simplify maintenance without requiring the UPS to be pulled from the rack. This unit is well suited as an extended run UPS for data closet or AV rack applications where connecting external battery packs later is a likely upgrade path.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e2U Rack\/Tower Form Factor\u003c\/strong\u003e — fits standard 19-inch rack enclosures or stands alone in tower configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual-Boost Automatic Voltage Regulation\u003c\/strong\u003e — corrects both slight undervoltages and severe brownouts without switching to battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMillisecond Transfer Time\u003c\/strong\u003e — switches to battery power fast enough to keep connected AV and network equipment running without reboot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSNMP-Ready Network Management\u003c\/strong\u003e — supports USB, RS-232, and an optional network management card slot for centralized power monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitched Load Banks\u003c\/strong\u003e — two independently controllable outlet groups enable scheduled or remote reboot and load shedding.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRotating LCD Display\u003c\/strong\u003e — reports operating mode and power data, adjustable for rack-mount or tower viewing angles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-Swappable Battery Modules\u003c\/strong\u003e — field-replaceable batteries simplify maintenance without removing the unit from the rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmergency Power Off Interface\u003c\/strong\u003e — supports EPO integration for facility safety systems.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBoardroom AV racks powering control processors, switchers, and network gear\u003c\/li\u003e\n\u003cli\u003eConference room equipment closets housing matrix switchers and DSPs\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space AV racks requiring network-grade uptime\u003c\/li\u003e\n\u003cli\u003eMulti-purpose room AV racks supporting rotating equipment configurations\u003c\/li\u003e\n\u003cli\u003eTraining room AV and network racks\u003c\/li\u003e\n\u003cli\u003eBroadcast studio racks powering encoders, routers, and control gear\u003c\/li\u003e\n\u003cli\u003eGovernment space AV and IT racks requiring reliable backup power\u003c\/li\u003e\n\u003cli\u003eHouse of worship AV and streaming equipment racks\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;min-width:480px;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;border:1px solid #ccc;padding:6px;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"text-align:left;border:1px solid #ccc;padding:6px;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eCapacity\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003e2200VA \/ 1920W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003ePower Factor\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003e0.87\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eTopology\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eLine-interactive, sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003e120V AC, NEMA 5-20P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003e110V\/115V\/120V nominal, ±5% in battery mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eOutlets\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003e4x 5-15R, 4x 5-15\/20R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003e2U rack\/tower, 23 in. minimum rack depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003e8.79 x 43.99 x 49.00 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003e26.13 kg (57.6 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eRuntime (full load, 1920W)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003e4.5 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eRuntime (half load, 960W)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003e12 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eEfficiency\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003e96% (line mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003e2-year warranty, 3 years with registration; $250,000 Ultimate Lifetime Insurance (U.S., Canada, Puerto Rico)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWill the SMART2200RMXL2U fit a standard 19-inch AV rack?\u003c\/h3\u003e\u003cp\u003eYes. It occupies 2U of vertical rack space and is designed for standard 19-inch rack enclosures, with a minimum rack depth of 23 inches required.\u003c\/p\u003e\u003ch3\u003eCan I add a network management card for remote monitoring?\u003c\/h3\u003e\u003cp\u003eYes. The unit includes a slot for an optional network management card in addition to built-in USB and RS-232 communication ports.\u003c\/p\u003e\u003ch3\u003eDoes this UPS support remote reboot of individual outlets?\u003c\/h3\u003e\u003cp\u003eYes. Two independently switched load banks allow scheduled or remote reboot and load shedding of connected equipment without physical access to the rack.\u003c\/p\u003e\u003ch3\u003eCan I extend the runtime with an external battery pack?\u003c\/h3\u003e\u003cp\u003eYes, this model supports optional external battery packs for extended runtime beyond the internal battery's rated capacity. Contact Creation Networks to confirm compatible battery pack models.\u003c\/p\u003e\u003ch3\u003eWhat is the switchover time to battery power?\u003c\/h3\u003e\u003cp\u003eTransfer from line power to battery occurs within approximately 5 milliseconds, fast enough to keep most AV and networking equipment running without a reboot.\u003c\/p\u003e\u003ch3\u003eWhat warranty coverage comes with this UPS?\u003c\/h3\u003e\u003cp\u003eThe SMART2200RMXL2U carries a 2-year warranty extendable to 3 years with registration, plus $250,000 Ultimate Lifetime Insurance coverage in the U.S., Canada, and Puerto Rico.\u003c\/p\u003e\u003ch3\u003eIs professional installation required for a commercial AV rack deployment?\u003c\/h3\u003e\u003cp\u003eWhile the unit itself installs like standard rack-mount equipment, Creation Networks recommends coordination with your AV integrator to properly size connected load and configure network monitoring for your rack.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":48159970492652,"sku":"SMART2200RMXL2U","price":1765.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/smart2200rmxl2u.jpg?v=1786678433","url":"https:\/\/creationnetworks.net\/products\/eaton-smart2200rmxl2u-2200va-ups-system-smartpro-rack-tower-line-interactive-120v-8-outlet","provider":"Creation Networks","version":"1.0","type":"link"}