{"product_id":"eaton-smart2200net-smartpro-120v-2-2kva-1-7kw-line-interactive-ups-tower-extended-run-3","title":"Eaton SMART2200NET – 2200VA Line-Interactive Tower UPS","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Eaton SMART2200NET is a 2200VA\/1700W line-interactive UPS built for network closets, server rooms, and commercial equipment racks that need reliable battery backup during utility outages. This tower-form UPS delivers extended run time and SNMP-ready network management, making it a common choice for IT infrastructure protection in data center and network closet deployments. Integrators specifying UPS with network card capability for switches, servers, or AV control racks will find the SMART2200NET's six outlets and three DB9 ports well suited to mixed IT and AV loads.\u003c\/p\u003e\n\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe SMART2200NET is a commercial-grade line-interactive UPS designed to protect servers, network switches, storage arrays, and AV control equipment from power outages, sags, and surges. Its line-interactive topology with automatic voltage regulation (AVR) corrects minor voltage fluctuations without switching to battery, extending battery life and reducing wear in facilities with unstable utility power. At full 1700W load the unit provides roughly 11 minutes of runtime, and at half load approximately 27 minutes, giving IT staff enough time for an orderly shutdown or generator transfer in a network closet or server room.\u003c\/p\u003e\n\u003cp\u003eSix NEMA 5-15R outlets are split across two independently switchable load banks, so non-critical equipment can be shed automatically to extend runtime for critical devices. The extended-run design supports external battery packs for facilities that need longer bridge time during commercial deployment scenarios such as a data center or a rack serving a boardroom or conference room AV system. Three DB9 ports (one RS232, two contact-closure) support integration with building management systems and network monitoring software, making this UPS a practical fit for centralized rack-mount installations where uptime monitoring matters. The tower chassis fits standard equipment racks or floor\/shelf installation in a network closet.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine-Interactive AVR\u003c\/strong\u003e — Corrects brownouts and overvoltage conditions without switching to battery, reducing battery wear during normal operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2200VA \/ 1700W Capacity\u003c\/strong\u003e — Sized for a network rack, small server room, or AV control closet with multiple connected devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSix NEMA 5-15R Outlets\u003c\/strong\u003e — Two independently switchable load banks let integrators prioritize critical equipment during an outage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended Run Support\u003c\/strong\u003e — Compatible with external battery packs for longer bridge time in commercial deployment applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree DB9 Communication Ports\u003c\/strong\u003e — One RS232 and two contact-closure ports for network monitoring and building management system integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePWM Sine Wave Output\u003c\/strong\u003e — Clean power on battery mode for sensitive network and server hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast Transfer Time\u003c\/strong\u003e — 2-4 millisecond transfer to battery protects connected equipment during utility interruptions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e$250,000 Ultimate Lifetime Insurance\u003c\/strong\u003e — Coverage for connected equipment damaged while properly connected to the UPS.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eNetwork closet\u003c\/li\u003e\n\u003cli\u003eServer room\u003c\/li\u003e\n\u003cli\u003eData center\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space\u003c\/li\u003e\n\u003cli\u003eBoardroom\u003c\/li\u003e\n\u003cli\u003eConference room\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e120V AC, 15A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Capacity\u003c\/td\u003e\n\u003ctd\u003e2200VA \/ 1700W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Regulation\u003c\/td\u003e\n\u003ctd\u003e-13%\/+5% (line mode), +\/-5% (battery mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaveform\u003c\/td\u003e\n\u003ctd\u003eSine wave (AC mode), PWM sine wave (battery mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Time\u003c\/td\u003e\n\u003ctd\u003e2-4 milliseconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eTower, 0U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e17\" x 9\" x 12.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e80 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlets\u003c\/td\u003e\n\u003ctd\u003eSix NEMA 5-15R (two switchable load banks)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connector\u003c\/td\u003e\n\u003ctd\u003eNEMA 5-15P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003e3 DB9 (1 RS232, 2 contact-closure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRuntime at Full Load\u003c\/td\u003e\n\u003ctd\u003e11 minutes (1700W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRuntime at Half Load\u003c\/td\u003e\n\u003ctd\u003e27 minutes (850W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eValve Regulated Lead Acid (VRLA), 24VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecharge Time\u003c\/td\u003e\n\u003ctd\u003eLess than 9 hours (10% to 90%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL 1778, CSA, NOM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-year standard, 3-year with registration; $250,000 Ultimate Lifetime Insurance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs the SMART2200NET compatible with network monitoring software?\u003c\/strong\u003e\u003cbr\u003eYes. The unit includes an RS232 DB9 port for connection to Eaton monitoring software, plus two contact-closure DB9 ports for building management system integration. An optional network management card can be added for SNMP-based remote monitoring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this UPS be rack-mounted?\u003c\/strong\u003e\u003cbr\u003eThe SMART2200NET ships in a tower configuration. It is designed for floor, shelf, or cabinet-base placement in a network closet or server room rather than a standard rack-mount rail installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow long will connected equipment run during an outage?\u003c\/strong\u003e\u003cbr\u003eAt full 1700W load, expect approximately 11 minutes of runtime. At half load (850W), runtime extends to approximately 27 minutes. Runtime can be extended further with compatible external battery packs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the two outlet banks?\u003c\/strong\u003e\u003cbr\u003eThe six NEMA 5-15R outlets are split into two independently switchable load banks. This lets an integrator shut down non-critical equipment automatically to extend runtime for critical devices such as network switches or servers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is covered under the warranty?\u003c\/strong\u003e\u003cbr\u003eThe SMART2200NET carries a 2-year standard warranty, extendable to 3 years with product registration, plus $250,000 in Ultimate Lifetime Insurance for connected equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this UPS support extended runtime for longer outages?\u003c\/strong\u003e\u003cbr\u003eYes. The extended-run design is compatible with external battery packs for facilities that need bridge time beyond the standard internal battery capacity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this UPS suitable for a mixed AV\/IT rack?\u003c\/strong\u003e\u003cbr\u003eYes. With six outlets, dual switchable load banks, and multiple communication ports, the SMART2200NET is commonly deployed in racks that combine network equipment with AV control processors and switchers in conference rooms and boardrooms.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat input and output connections does it use?\u003c\/strong\u003e\u003cbr\u003eInput is a standard NEMA 5-15P plug; output is six NEMA 5-15R outlets, both common in North American commercial electrical installations.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":48159968362732,"sku":"SMART2200NET","price":1525.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/smart2200net.jpg?v=1786678370","url":"https:\/\/creationnetworks.net\/products\/eaton-smart2200net-smartpro-120v-2-2kva-1-7kw-line-interactive-ups-tower-extended-run-3","provider":"Creation Networks","version":"1.0","type":"link"}