{"product_id":"eaton-sm2200rmxl2up-2200va-1920w-ups-smart-rackmount-sine-wave-lcd-avr-120v-usb-2u","title":"Eaton SM2200RMXL2UP – 2200VA 2U Rack Sine Wave UPS","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Eaton SM2200RMXL2UP is a 2U rack-mount UPS built for network closets, data centers, and server rooms that need clean, uninterrupted power for switches, servers, and AV control racks. Rated 2200VA \/ 1920W with pure sine wave output, this line-interactive UPS keeps sensitive commercial-grade equipment running through brownouts, surges, and short utility outages. Integrators specifying a rack-mount UPS for network closet or data center deployment get automatic voltage regulation (AVR), an LCD status display, and USB\/serial connectivity for remote monitoring. It is a practical fit for any 19-inch rack where uptime for networking and AV control gear is non-negotiable.\u003c\/p\u003e\n\n\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe SM2200RMXL2UP delivers 2200VA\/1920W of line-interactive UPS protection in a compact 2U rack-mount enclosure, making it well suited for server racks, network closets, and equipment rooms with limited rack space. Pure sine wave output ensures compatibility with active PFC power supplies commonly found in servers, network switches, and AV matrix switchers, so connected equipment runs exactly as it would on utility power. Built-in automatic voltage regulation (AVR) corrects minor brownouts and overvoltage conditions without switching to battery, extending battery life and reducing runtime events during a commercial deployment. The unit provides eight total outlets split across always-on and switched load banks, letting integrators sequence non-critical loads to shed first during an outage and preserve runtime for core network and AV equipment. A front-panel LCD interface displays load level, battery status, and input\/output voltage at a glance, which simplifies commissioning and day-to-day facilities monitoring in a data center or network closet installation. USB and RS-232 ports support UPS monitoring software, and an available network management card slot allows remote SNMP monitoring across a commercial network, a feature IT and facilities teams rely on for unattended equipment rooms. The 5-20P input plug matches standard 120V commercial branch circuits used in server rooms and AV racks. For any conference room control rack, network closet, or data center cabinet where a power interruption would take down AV switching, network gear, or building systems, this UPS provides a dependable line-interactive buffer between utility power and connected equipment.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e2200VA \/ 1920W Capacity\u003c\/strong\u003e — Supports a rack of network switches, servers, or AV control equipment without oversizing the UPS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePure Sine Wave Output\u003c\/strong\u003e — Matches utility power waveform for clean compatibility with active PFC power supplies in servers and AV gear.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic Voltage Regulation (AVR)\u003c\/strong\u003e — Corrects brownouts and overvoltage on the fly without draining the battery, extending battery service life.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2U Rack-Mount Form Factor\u003c\/strong\u003e — Fits standard 19-inch server racks and AV equipment racks with minimal space impact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEight Outlets with Switched Load Banks\u003c\/strong\u003e — Always-on and switched banks let integrators shed non-critical loads first during an outage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInteractive LCD Display\u003c\/strong\u003e — Shows load, battery status, and voltage for fast on-site diagnostics during installation or maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSB and RS-232 Connectivity\u003c\/strong\u003e — Enables UPS monitoring and automated shutdown software integration with servers and network gear.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Network Management Card Slot\u003c\/strong\u003e — Supports remote SNMP monitoring for unattended network closets and data centers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-Swappable Battery Design\u003c\/strong\u003e — Replace the battery pack without powering down connected equipment, minimizing downtime in critical installs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eNetwork closet\u003c\/li\u003e\n\u003cli\u003eData center\u003c\/li\u003e\n\u003cli\u003eServer room\u003c\/li\u003e\n\u003cli\u003eGovernment space\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity\u003c\/td\u003e\n\u003ctd\u003e2200VA \/ 1920W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e110\/120V nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Waveform\u003c\/td\u003e\n\u003ctd\u003ePure sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor\u003c\/td\u003e\n\u003ctd\u003e0.87\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eLine-interactive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connector\u003c\/td\u003e\n\u003ctd\u003eNEMA 5-20P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eValve Regulated Lead Acid (VRLA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRuntime at Full Load (1920W)\u003c\/td\u003e\n\u003ctd\u003e4.5 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRuntime at Half Load\u003c\/td\u003e\n\u003ctd\u003e12 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement Battery\u003c\/td\u003e\n\u003ctd\u003eRBC94-2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003e570 joules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlets\u003c\/td\u003e\n\u003ctd\u003e4x NEMA 5-15R, 4x NEMA 5-15\/20R (includes 2 switched load bank outlets)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunications\u003c\/td\u003e\n\u003ctd\u003eUSB, RS-232, EPO, optional network management card slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eInteractive LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003e2U rack\/tower\/wall-mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (D x W x H)\u003c\/td\u003e\n\u003ctd\u003e24\" x 21.7\" x 8.8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e64 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise Level\u003c\/td\u003e\n\u003ctd\u003e45 dBA maximum (1m, front)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e96% line-mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL 1778, CSA, FCC Class A, RoHS, TAA compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2 years standard (3 years with registration); $250,000 Ultimate Lifetime Insurance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWill this UPS work with active PFC server power supplies?\u003c\/strong\u003e Yes. The pure sine wave output is compatible with active PFC power supplies used in servers, network switches, and AV control processors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow is this UPS mounted in a rack?\u003c\/strong\u003e It ships as a 2U rack\/tower\/wall-mount unit and installs in a standard 19-inch rack using included rail hardware, or can stand alone in a network closet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I monitor this UPS remotely over the network?\u003c\/strong\u003e Yes, with an optional network management card installed in the card slot, the UPS supports SNMP-based remote monitoring alongside its standard USB and RS-232 ports.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow long will connected equipment run on battery?\u003c\/strong\u003e Runtime is rated at approximately 4.5 minutes at full 1920W load and about 12 minutes at half load, enough to ride through short outages or trigger a graceful shutdown.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the input plug type, and will it fit my existing circuit?\u003c\/strong\u003e The unit uses a NEMA 5-20P input plug for a 120V branch circuit, standard in most commercial server rooms and equipment racks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat warranty coverage comes with this UPS?\u003c\/strong\u003e It carries a 2-year standard warranty, extendable to 3 years with product registration, plus $250,000 Ultimate Lifetime Insurance coverage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan the battery be replaced without shutting down connected equipment?\u003c\/strong\u003e Yes, the battery pack (replacement part RBC94-2U) is designed for hot-swap replacement to minimize downtime during maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this UPS suitable for a shared IT\/AV equipment rack?\u003c\/strong\u003e Yes. With eight outlets split across always-on and switched load banks, it can protect network switches, servers, and AV control gear in the same rack while allowing non-critical loads to shed first during an outage.\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Eaton","offers":[{"title":"Default Title","offer_id":48159968329964,"sku":"SM2200RMXL2UP","price":1782.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/sm2200rmxl2up.jpg?v=1786678370","url":"https:\/\/creationnetworks.net\/products\/eaton-sm2200rmxl2up-2200va-1920w-ups-smart-rackmount-sine-wave-lcd-avr-120v-usb-2u","provider":"Creation Networks","version":"1.0","type":"link"}