{"product_id":"eaton-pdumvr30netlx-managed-rack-pdu","title":"Eaton PDUMVR30NETLX – 0U Vertical Switched PDU, 120V","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe Eaton PDUMVR30NETLX is a 0U vertical switched PDU built for 120V server rooms, network closets, and AV racks that need remote outlet control without consuming rack space. Rated for 120V, 24A input and 2.9 kW maximum output across 24 NEMA 5-20R outlets, it is sized for racks of standard servers, switches, and low-voltage AV equipment rather than high-density 208V deployments. As a 0U vertical PDU for network closet installations, its LX platform network interface delivers remote outlet switching and monitoring from a browser-based interface. Integrators standardizing on 120V rack power in commercial spaces get network-based outlet control alongside a high outlet count from a single vertical unit.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/PDUMVR30NETLX_C.jpg?v=1782802346\" alt=\"Eaton PDUMVR30NETLX rack PDU\" style=\"max-width:100%;height:auto;\"\u003e\u003c\/p\u003e\u003cp\u003eThe PDUMVR30NETLX is part of the Eaton Tripp Lite series switched PDU family built on the LX platform interface, which provides network-based outlet switching and monitoring through a web management console. Input is delivered through a NEMA L5-30P plug rated 120V at 24A, feeding 24 NEMA 5-20R outlets for a maximum output of 2.9 kW, making it well suited to racks of standard servers, network switches, and commercial AV equipment that run on 120V power. The 0U vertical form factor mounts along the rear rail of the rack, preserving all horizontal rack units for equipment rather than the PDU itself, which matters in network closets and AV racks where space is already tight. Outlet-level switching and monitoring are managed through the pre-installed LX network card, allowing IT and AV support staff to remotely power-cycle individual devices, monitor load in real time via a built-in digital ammeter, and schedule reboots without visiting the rack in person. This capability is useful for organizations managing distributed network closets or AV racks in commercial meeting spaces and government facilities, where dispatching a technician for a routine reboot is inefficient. Because the unit runs on standard 120V power rather than 208V, it fits a wider range of existing commercial electrical circuits, simplifying deployment in facilities not built with dedicated three-phase or high-voltage data center power. At approximately 70 inches of mounting length and just under 10 lb, the PDUMVR30NETLX is designed for full-height enclosures needing a high outlet count on a single 120V circuit. Built to UL 60950-1, FCC Class A, and CSA standards, it is suited to commercial and government facilities with formal electrical compliance requirements.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e0U Vertical Mounting\u003c\/strong\u003e — Installs along the rear rail of the rack, keeping all horizontal rack units available for equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e24 NEMA 5-20R Outlets\u003c\/strong\u003e — Provides a high outlet count for racks of standard servers, switches, and AV equipment on 120V power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLX Platform Network Management\u003c\/strong\u003e — Delivers browser-based remote outlet switching and real-time load monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-In Digital Ammeter\u003c\/strong\u003e — Allows on-site load verification in addition to remote monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard 120V Input\u003c\/strong\u003e — Installs on common commercial circuits without requiring dedicated 208V or three-phase power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote Power Cycling\u003c\/strong\u003e — Reduces the need for on-site technician visits to reboot unresponsive equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 60950-1 and FCC Class A Compliance\u003c\/strong\u003e — Meets standards required for commercial and government facility deployments.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eServer room\u003c\/li\u003e\n\u003cli\u003eNetwork closet\u003c\/li\u003e\n\u003cli\u003eGovernment space\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space\u003c\/li\u003e\n\u003cli\u003eBroadcast studio\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e120V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\/Amperage\u003c\/td\u003e\n\u003ctd\u003e24A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Plug\u003c\/td\u003e\n\u003ctd\u003eNEMA L5-30P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Receptacles\/Outlets\u003c\/td\u003e\n\u003ctd\u003e24x NEMA 5-20R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Rating\u003c\/td\u003e\n\u003ctd\u003e2.9 kW max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\/Form Factor\u003c\/td\u003e\n\u003ctd\u003e0U vertical rack-mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring Type\u003c\/td\u003e\n\u003ctd\u003eSwitched\/Managed — LX platform network card, digital ammeter, remote outlet control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 70\" H x 2.2\" W x 2.05\" D; 9.94 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL 60950-1, RoHS, FCC Class A, NOM, CSA Std. C22.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eNot published by manufacturer for this specific SKU. Contact Eaton\/Creation Networks for warranty terms.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eIs the PDUMVR30NETLX compatible with standard 120V commercial circuits?\u003c\/h3\u003e\u003cp\u003eYes. It runs on a standard 120V, 24A circuit through a NEMA L5-30P plug, making it compatible with common commercial building power without requiring a 208V upgrade.\u003c\/p\u003e\u003ch3\u003eWhat rack height does this PDU require?\u003c\/h3\u003e\u003cp\u003eIts approximately 70-inch mounting length is designed for full-height enclosures. Confirm your cabinet's rear rail clearance before ordering.\u003c\/p\u003e\u003ch3\u003eCan I monitor load without logging into the network interface?\u003c\/h3\u003e\u003cp\u003eYes. The unit includes a built-in digital ammeter for on-site load verification in addition to remote network-based monitoring.\u003c\/p\u003e\u003ch3\u003eIs this PDU suitable for AV racks in a commercial meeting space?\u003c\/h3\u003e\u003cp\u003eYes. Its standard 120V input and high outlet count make it a practical fit for AV equipment racks in meeting rooms and presentation spaces.\u003c\/p\u003e\u003ch3\u003eHow is the LX platform network card managed?\u003c\/h3\u003e\u003cp\u003eThe pre-installed LX network interface provides browser-based access for remote outlet switching, monitoring, and alerting, and integrates with existing IT network infrastructure.\u003c\/p\u003e\u003ch3\u003eWhat is the warranty on the PDUMVR30NETLX?\u003c\/h3\u003e\u003cp\u003eSpecific warranty terms for this SKU were not published in available manufacturer documentation. Contact Eaton or Creation Networks to confirm coverage before purchase.\u003c\/p\u003e\u003ch3\u003eCan Creation Networks help determine if I need the 120V or 208V version of this PDU?\u003c\/h3\u003e\u003cp\u003eYes. Creation Networks can help confirm your facility's available voltage and recommend the PDUMVR30NETLX or the higher-voltage PDUMVR30HVNETLX accordingly.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":47865663684844,"sku":"PDUMVR30NETLX","price":1149.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/PDUMVR30NETLX_C.jpg?v=1782802346","url":"https:\/\/creationnetworks.net\/products\/eaton-pdumvr30netlx-managed-rack-pdu","provider":"Creation Networks","version":"1.0","type":"link"}