{"product_id":"eaton-pdumv32hvnetlx-pdu-switched-7-4kw-230v-32a-blue-iec-309-lx-interface-0urm-taa","title":"Eaton PDUMV32HVNETLX – 7.4kW Switched PDU, LX Interface","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe Eaton PDUMV32HVNETLX is a 0U switched rack PDU delivering 7.4kW at 230V\/32A through 24 individually controllable outlets, built for data centers, server rooms, and network closets that need remote power control. With a built-in LX Platform network interface, this switched PDU gives operations teams the ability to turn on, turn off, reboot, or lock out power to individual outlets without a site visit. The IEC 309 32A Blue input plug and 0U vertical mounting make it a straightforward fit for existing rack cabinets running on single-phase 230V power. Facilities managing remote or unmanned data center sites will benefit from the reduction in truck rolls this switched PDU enables.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eThis 0U switched PDU distributes, monitors, and manages network-grade AC power for equipment mounted in a standard 19-inch rack. It is recommended for data centers, server rooms, and network closets where administrators need advanced network control and remote power monitoring, with the ability to turn on, turn off, reboot, or lock out power to each outlet individually. Being able to manage network power consumption and balance loads remotely, without visiting the site, helps reduce the ongoing cost of data center maintenance. During normal operation, 24 individually controllable outlets — 20 C13 and four C19 — distribute AC power to connected equipment, each accompanied by an LED that illuminates when the outlet is energized and ready for use. The outlets are split into two load banks, each protected by its own circuit breaker that trips if the connected load on that bank exceeds its maximum rating, and plug-lock insert sleeves are included to keep connected cords from working loose. A digital load meter reports the load for each outlet bank separately as well as the total connected load, which helps prevent the kind of overload that leads to costly downtime or damaged equipment. The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications over a secure web browser, SNMP, telnet, or SSH, with 10\/100 Mbps auto-sensing Ethernet connectivity and support for IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1-3, telnet, SSH, FTP, DHCP, and NTP. The 0U PDU mounts vertically in an EIA-standard 19-inch rack using the included toolless mounting buttons or brackets, and the optional PDUMVROTATEBRKT kit allows the outlets to face the rear for better airflow or equipment access. A 10-foot cord with an IEC 309 32A Blue (2P+E) input plug connects the single-phase PDU to a compatible AC source, generator, or protected UPS system. The PDUMV32HVNETLX is TAA-compliant for GSA Schedule purchases and is backed by a 2-year warranty.\u003c\/p\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/pdumv32hvnetlx.jpg?v=1786673861\" alt=\"Eaton PDUMV32HVNETLX switched rack PDU with LX Platform interface\"\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e24 Individually Switched Outlets\u003c\/strong\u003e — 20 C13 and 4 C19 outlets can each be turned on, off, or rebooted remotely without a site visit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-In LX Platform Network Card\u003c\/strong\u003e — Java-free HTML5 web interface supports SNMP, telnet, SSH, and secure browser access for 24\/7 remote management.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Load Metering\u003c\/strong\u003e — Separate ammeter readings for each outlet bank and total load help prevent overloads before they trip a breaker.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0U Vertical Mounting\u003c\/strong\u003e — Toolless mounting buttons or brackets install the PDU in the vertical cable channel of a standard 19-inch rack without consuming rack units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 309 32A Blue Input\u003c\/strong\u003e — A 10-foot cord connects directly to 230V single-phase mains, generator, or protected UPS power sources.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional EnviroSense2 Support\u003c\/strong\u003e — Add-on environmental monitoring modules extend the PDU's monitoring beyond power to temperature and humidity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-Year Manufacturer Warranty\u003c\/strong\u003e — Backed by Eaton's 2-year warranty for added confidence in data center deployments.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eData center\u003c\/li\u003e\n\u003cli\u003eServer room\u003c\/li\u003e\n\u003cli\u003eNetwork closet\u003c\/li\u003e\n\u003cli\u003eColocation facility\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Capacity\u003c\/td\u003e\n\u003ctd\u003e7.4kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlets\u003c\/td\u003e\n\u003ctd\u003e24 total (20 C13, 4 C19)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Plug\u003c\/td\u003e\n\u003ctd\u003eIEC 309 32A Blue (2P+E)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003e0U rack-mount (vertical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Interface\u003c\/td\u003e\n\u003ctd\u003eLX Platform, HTML5, SNMP\/telnet\/SSH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eCan individual outlets be switched remotely?\u003c\/h3\u003e\u003cp\u003eYes, each of the 24 outlets can be turned on, off, or rebooted independently through the built-in LX Platform network interface, without requiring a site visit.\u003c\/p\u003e\u003ch3\u003eWhat network protocols does the LX Platform support?\u003c\/h3\u003e\u003cp\u003eThe interface supports HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP, and NTP over a 10\/100 Mbps auto-sensing Ethernet connection.\u003c\/p\u003e\u003ch3\u003eHow does this PDU mount in a rack?\u003c\/h3\u003e\u003cp\u003eIt mounts in 0U of space using toolless mounting buttons or included brackets, and the optional PDUMVROTATEBRKT kit lets you install it with outlets facing the rear for better airflow or access.\u003c\/p\u003e\u003ch3\u003eWhat input power does the PDU require?\u003c\/h3\u003e\u003cp\u003eIt uses a 10-foot cord with an IEC 309 32A Blue (2P+E) plug, connecting to a 230V single-phase source, generator, or protected UPS system.\u003c\/p\u003e\u003ch3\u003eCan I add environmental monitoring to this PDU?\u003c\/h3\u003e\u003cp\u003eYes, optional EnviroSense2 modules, sold separately, add environmental monitoring capabilities alongside the PDU's power management features.\u003c\/p\u003e\u003ch3\u003eIs this PDU eligible for federal or GSA purchases?\u003c\/h3\u003e\u003cp\u003eYes, the PDUMV32HVNETLX is TAA-compliant, making it eligible for GSA Schedule purchases.\u003c\/p\u003e\u003ch3\u003eWhat warranty comes with this PDU?\u003c\/h3\u003e\u003cp\u003eIt is backed by Eaton's 2-year manufacturer warranty; contact Creation Networks for details on extended coverage options.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":48159670599916,"sku":"PDUMV32HVNETLX","price":1139.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/pdumv32hvnetlx.jpg?v=1786673861","url":"https:\/\/creationnetworks.net\/products\/eaton-pdumv32hvnetlx-pdu-switched-7-4kw-230v-32a-blue-iec-309-lx-interface-0urm-taa","provider":"Creation Networks","version":"1.0","type":"link"}