{"product_id":"eaton-pdumv20hv-pdu-metered-208v-240v-20a-6-c19-32-c13-c20-vertical-0urm","title":"Eaton PDUMV20HV – 0U Vertical Metered PDU, 38 Outlets","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe Eaton PDUMV20HV is a vertical 0U metered PDU designed to power dense rack enclosures without consuming horizontal rack space. Rated for 20A at 208\/230\/240V (agency derated to 16A), it distributes power through 32 C13 and 6 C19 outlets — supporting up to 38 directly connected pieces of networking or server equipment. A built-in two-character LED display gives IT managers continuous local current monitoring in one-amp increments, helping prevent overloads in high-density server rooms and network closets. This vertical metered rack PDU is well suited for data centers and colocation facilities that need maximum outlet count with minimal footprint.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eBuilt for high-density rack power distribution, the PDUMV20HV mounts vertically in 0U of space, using tooless mounting brackets that fit standard button-mount compatible 2-post and 4-post racks, as well as under-counter or wallmount configurations. Its 63.75 in. vertical chassis carries 32 C13 and 6 C19 outlets arranged in a single unbreakered load bank, giving integrators the outlet density needed to power a full rack of servers, switches, and other IEC-320 equipped equipment from one PDU. A built-in, easy-to-read two-character LED display continuously reports PDU output current in one-amp increments, giving IT managers real-time visibility into load levels to prevent mains, generator, UPS, or PDU overloads and to help maintain proper load balance in complex redundant power applications. The switch-free, unfiltered electrical pass-through design reliably distributes power from a UPS or generator to connected equipment without adding switching latency or points of failure. A 10 ft. detachable line cord with an L6-20P input plug connects the unit to the facility's power source, and plug retention brackets help keep connected equipment securely plugged in and continuously powered even in racks subject to frequent cable movement. Rated for 20A maximum capacity at 208\/230\/240V (agency derated to 16A), this PDU is a strong fit for data centers, server rooms, and network closets that need to power a large number of devices from a single vertical PDU without sacrificing horizontal rack space.\u003c\/p\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/pdumv20hv.jpg?v=1786673934\" alt=\"Eaton PDUMV20HV 0U vertical metered PDU with C13 and C19 outlets\"\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e38-Outlet Capacity\u003c\/strong\u003e — 32 C13 and 6 C19 outlets support up to 38 directly connected servers, switches, or other IEC-320 devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0U Vertical Mounting\u003c\/strong\u003e — Tooless mounting brackets install in button-mount compatible 2-post and 4-post racks without consuming horizontal rack units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocal Digital Metering\u003c\/strong\u003e — A built-in two-character LED display continuously reports output current in one-amp increments for real-time load visibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetachable L6-20P Input Cord\u003c\/strong\u003e — A 10 ft. detachable line cord simplifies installation and replacement without rewiring the PDU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlug Retention Brackets\u003c\/strong\u003e — Keep connected power cords securely seated to prevent accidental disconnects in busy rack environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitch-Free Pass-Through Design\u003c\/strong\u003e — Unfiltered electrical pass-through reliably distributes UPS or generator power without added switching complexity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eData center\u003c\/li\u003e\n\u003cli\u003eServer room\u003c\/li\u003e\n\u003cli\u003eColocation facility\u003c\/li\u003e\n\u003cli\u003eNetwork closet\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e208-240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Current\u003c\/td\u003e\n\u003ctd\u003e20A (agency derated to 16A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Plug\u003c\/td\u003e\n\u003ctd\u003eL6-20P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Cord Length\u003c\/td\u003e\n\u003ctd\u003e10 ft., detachable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Outlets\u003c\/td\u003e\n\u003ctd\u003e32 x C13, 6 x C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003e0U vertical, 63.75 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eHow does the PDUMV20HV mount in a rack without using rack units?\u003c\/h3\u003e\u003cp\u003eIt uses a 0U vertical mounting design with tooless brackets that install in button-mount compatible 2-post and 4-post racks, running along the side of the enclosure instead of occupying horizontal U space.\u003c\/p\u003e\u003ch3\u003eHow many devices can this PDU power?\u003c\/h3\u003e\u003cp\u003eThe 32 C13 and 6 C19 outlets support up to 38 directly connected pieces of server or networking equipment.\u003c\/p\u003e\u003ch3\u003eDoes this PDU support remote network monitoring?\u003c\/h3\u003e\u003cp\u003eThis model provides local monitoring via its built-in two-character LED current display; it does not include a network management card for remote SNMP or web access.\u003c\/p\u003e\u003ch3\u003eWhat input connection does the PDUMV20HV use?\u003c\/h3\u003e\u003cp\u003eIt uses a 10 ft. detachable line cord terminating in an L6-20P plug, rated for 208\/230\/240V circuits.\u003c\/p\u003e\u003ch3\u003eCan this PDU be wall-mounted or installed under a counter instead of in a rack?\u003c\/h3\u003e\u003cp\u003eYes. The included mounting brackets support vertical rack installation as well as wallmount and under-counter configurations.\u003c\/p\u003e\u003ch3\u003eWhat warranty applies to this unit?\u003c\/h3\u003e\u003cp\u003eEaton backs this unit with its standard manufacturer warranty; contact Creation Networks for the current term and any extended coverage options.\u003c\/p\u003e\u003ch3\u003eCan Creation Networks help determine if this PDU fits our rack's outlet requirements?\u003c\/h3\u003e\u003cp\u003eYes, our team can review your equipment list and rack layout to confirm outlet count and mounting compatibility before you order.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":48159672500460,"sku":"PDUMV20HV","price":346.49,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/pdumv20hv.jpg?v=1786673934","url":"https:\/\/creationnetworks.net\/products\/eaton-pdumv20hv-pdu-metered-208v-240v-20a-6-c19-32-c13-c20-vertical-0urm","provider":"Creation Networks","version":"1.0","type":"link"}