{"product_id":"eaton-pdumnv32hv2lx-metered-input-rack-pdu","title":"Eaton PDUMNV32HV2LX – 7.7kW Metered PDU, IEC 32A Input","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe Eaton PDUMNV32HV2LX is a high-capacity, 0U vertical metered rack PDU built for data center and colocation cabinet racks that need more headroom than a standard 24A circuit provides. Its 32A IEC 60309 input and 7.7kW output rating make it a fit for a 32A metered rack PDU installation feeding a dense server, network, or AV equipment rack from a single high-amperage single-phase circuit. Integrators specifying this SKU should confirm that the facility has 200-240V IEC 60309 32A receptacles available, since this plug type is more common in international and purpose-built data center power distribution than in typical North American commercial buildings.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eThe PDUMNV32HV2LX is a single-phase, 0U vertical metered PDU designed to mount along the rear rail of a server rack or open-frame cabinet. It draws input power through a 200-240V IEC 60309 32A (2P+E) blue plug on a 10-foot cord and delivers up to 7.7kW of output across 36 C13 and 6 C19 outlets, giving it the same high outlet density as other units in the PDUMNV line but at a higher current and power rating. A built-in metered interface with digital ammeter functionality lets on-site technicians confirm load during a rack PDU installation or after adding new equipment, which is valuable in racks running at or near their rated capacity. This IEC 60309 PDU for high-density racks is commonly specified where equipment loads exceed what a 20A or 24A NEMA-plug PDU can safely support, such as blade server chassis, dense switch fabrics, or racks combining IT and AV signal processing gear. Because of its 32A\/200-240V input requirement, it is best suited to data centers, colocation cabinets, and purpose-built server rooms with IEC 60309 receptacles or whips already in place, rather than standard commercial office wiring. The 0U vertical form factor keeps the PDU out of usable rack space, running along the rear rail for the full height of the enclosure, while its 42-outlet layout allows a single unit to service a fully populated rack without a second PDU or a separate branch circuit.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e32A IEC 60309 Input\u003c\/strong\u003e — Supports higher current draw than standard 20A\/24A NEMA-plug PDUs for dense equipment racks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e7.7kW Output Capacity\u003c\/strong\u003e — Delivers more usable power per PDU than the 5.5kW models in the same product family.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e42-Outlet Density\u003c\/strong\u003e — 36 C13 and 6 C19 receptacles support a fully loaded rack of servers, switches, and AV equipment from one unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Ammeter Metering\u003c\/strong\u003e — On-site current readout helps confirm load balance during installation, moves, adds, and changes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0U Vertical Form Factor\u003c\/strong\u003e — Rear-rail mounting preserves all horizontal rack units for equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Operating Temperature Range\u003c\/strong\u003e — Rated to 122°F (50°C), suiting warmer data center hot-aisle environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternational-Standard Plug Type\u003c\/strong\u003e — IEC 60309 input aligns with data center and colocation facilities built to international electrical standards.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003edata center\u003c\/li\u003e\n\u003cli\u003ecolocation cabinet\u003c\/li\u003e\n\u003cli\u003eserver room\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e200-240V AC, single-phase, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Current\/Amperage\u003c\/th\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Plug\u003c\/th\u003e\n\u003ctd\u003eIEC 60309 32A, 2P+E, blue; 10 ft. cord\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Receptacles\/Outlets\u003c\/th\u003e\n\u003ctd\u003e42 total: 36x IEC C13, 6x IEC C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Rating\u003c\/th\u003e\n\u003ctd\u003e7.7 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\/Form Factor\u003c\/th\u003e\n\u003ctd\u003e0U vertical rack-mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMonitoring Type\u003c\/th\u003e\n\u003ctd\u003eMetered (digital ammeter, LX interface)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e69.92 in H x 2.2 in W x 2.65 in D; approx. 9.7 lb (per manufacturer listing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertifications\u003c\/th\u003e\n\u003ctd\u003eEN 60950-1, IEC 60950-1, CE marked, FCC Part 15 Class A, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eContact Eaton\/Creation Networks for warranty terms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat kind of electrical circuit does this PDU require?\u003c\/h3\u003e\u003cp\u003eIt requires a 200-240V, single-phase circuit terminated with an IEC 60309 32A (2P+E) receptacle. This differs from the NEMA L6-30 or L6-20 receptacles used by many North American commercial buildings, so confirm your facility's whip or receptacle type before ordering.\u003c\/p\u003e\u003ch3\u003eHow many outlets does this PDU provide and what type?\u003c\/h3\u003e\u003cp\u003eIt provides 42 total outlets: 36 IEC C13 and 6 IEC C19, matching the standard C14 and C20 power cords used on most rack-mount servers, switches, and AV equipment.\u003c\/p\u003e\u003ch3\u003eIs this PDU compatible with North American 120V equipment?\u003c\/h3\u003e\u003cp\u003eThe PDU itself is a 200-240V unit; connected equipment must accept C13\/C19-style power inputs rated for that voltage range, which is standard on most enterprise-class servers and network switches sold globally.\u003c\/p\u003e\u003ch3\u003eHow is this PDU mounted in a rack?\u003c\/h3\u003e\u003cp\u003eIt is a 0U vertical PDU that mounts along the rear rail of a standard rack or open-frame cabinet, leaving horizontal rack units available for equipment.\u003c\/p\u003e\u003ch3\u003eWhat monitoring capability does this PDU offer?\u003c\/h3\u003e\u003cp\u003eIt includes a metered LX interface with digital ammeter functionality for on-site load verification; confirm current network monitoring feature availability with Eaton or Creation Networks if remote SNMP polling is required for your deployment.\u003c\/p\u003e\u003ch3\u003eWhat is the warranty on this product?\u003c\/h3\u003e\u003cp\u003eContact Eaton or Creation Networks directly to confirm current warranty terms for this SKU.\u003c\/p\u003e\u003ch3\u003eCan Creation Networks help confirm compatibility before I order?\u003c\/h3\u003e\u003cp\u003eYes. Our team can help verify your facility's input circuit type, available amperage, and outlet requirements before you commit to a 32A IEC-input PDU for your data center or server room rack.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":47865656377580,"sku":"PDUMNV32HV2LX","price":659.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/PDUMNV32HV2LX_0_9001c793-d8b3-45f8-afed-518e9879f2f2.jpg?v=1786640208","url":"https:\/\/creationnetworks.net\/products\/eaton-pdumnv32hv2lx-metered-input-rack-pdu","provider":"Creation Networks","version":"1.0","type":"link"}