{"product_id":"eaton-pdumnv30lx-metered-input-rack-pdu","title":"Eaton PDUMNV30LX – 0U Vertical Rack PDU, 24-Outlet","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe Eaton PDUMNV30LX is a 0U vertical rack PDU built for 120V racks that need high outlet density without giving up horizontal rack unit space. With twenty-four outlets on a single 30A circuit, it is a strong fit for a high-density vertical PDU for data center rack deployments where server rooms and network closets are packing more equipment into the same footprint. Integrators specifying a monitored 0U PDU with NIC for data center or colocation cabinet installs get both outlet count and network-based monitoring in one vertical strip.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/PDUMNV30LX_C.jpg?v=1782802197\" alt=\"Eaton PDUMNV30LX rack PDU\" style=\"max-width:100%;height:auto;\"\u003e\u003cp\u003eThe Eaton PDUMNV30LX is a 2.9kW single-phase rack PDU designed for 120V equipment racks that require higher outlet density than a standard 15A vertical PDU can provide. It mounts vertically (0U) along the rack's side channel, spans 70 inches to reach equipment across a full-height cabinet, and terminates its 10-ft input cord in a NEMA L5-30P locking plug rated for a 30A circuit (24A per agency de-rating). On the output side, it provides twenty-four outlets, giving integrators room to power a large number of low- to medium-draw devices, such as network switches, KVM extenders, and AV signal processing equipment, from a single PDU.\u003c\/p\u003e\u003cp\u003eLike other PDUMN-series units, the PDUMNV30LX uses Eaton's LX Platform interface and includes an integrated network card (NIC) with SNMP support, allowing IT and facilities teams to monitor output current remotely across a data center or colocation cabinet rather than checking each rack in person. This is particularly useful in high-density server room deployments where dozens of racks need centralized power monitoring. Because it mounts in 0U, it also frees every rack unit in the cabinet for switches, servers, or AV rack equipment.\u003c\/p\u003e\u003cp\u003eThe PDUMNV30LX is UL 60950-1 and CSA C22.2 certified, NOM compliant, and TAA compliant, making it suitable for government data center and colocation cabinet installations as well as commercial server rooms. For integrators standardizing a rack fleet on high-outlet-count vertical PDUs, this model pairs a 30A circuit with twenty-four outlets, reducing the number of PDUs needed to power a densely populated rack.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwenty-Four Outlets\u003c\/strong\u003e — Provides high outlet density on a single vertical PDU for densely populated 120V equipment racks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0U Vertical Mounting\u003c\/strong\u003e — Spans 70 inches along the rack's side channel, leaving every horizontal rack unit available for equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNEMA L5-30P Locking Input Plug\u003c\/strong\u003e — Connects to a 30A circuit (24A agency de-rated) via a 10-ft cord for stable, high-capacity power delivery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Network Card with SNMP\u003c\/strong\u003e — Supports remote, network-based monitoring of output current across a data center rack fleet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLX Platform Interface\u003c\/strong\u003e — Combines local digital metering with network monitoring capability in one PDU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2.9kW Power Capacity\u003c\/strong\u003e — Suited to powering a large number of network, KVM, and AV devices from a single circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTAA Compliant and UL Listed\u003c\/strong\u003e — Supports government and enterprise procurement standards for data center deployment.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eData center\u003c\/li\u003e\n\u003cli\u003eColocation cabinet\u003c\/li\u003e\n\u003cli\u003eServer room\u003c\/li\u003e\n\u003cli\u003eNetwork closet\u003c\/li\u003e\n\u003cli\u003eGovernment space\u003c\/li\u003e\n\u003cli\u003eBroadcast studio\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120V single-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Current\/Amperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30A max (agency de-rated to 24A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Plug\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNEMA L5-30P, 10-ft cord\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Receptacles\/Outlets\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24x NEMA 5-15\/20R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Rating (kW\/VA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.9kW (120V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\/Form Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0U vertical rack-mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitoring Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMonitored — LX Platform interface with integrated network card (NIC), SNMP support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70\"H x 2.19\"W x 1.75\"D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 60950-1, CSA C22.2, NOM, RoHS, FCC Part 15 Class A, TAA compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEaton Tripp Lite series PDUs typically carry a 2-year limited warranty; contact Eaton\/Creation Networks for exact terms on this SKU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eHow many outlets does the PDUMNV30LX provide?\u003c\/h3\u003e\u003cp\u003eIt provides twenty-four outlets along a 70-inch vertical strip, supporting high outlet density in a single rack PDU.\u003c\/p\u003e\u003ch3\u003eWhat circuit does this PDU require?\u003c\/h3\u003e\u003cp\u003eThe PDUMNV30LX requires a 120V circuit rated up to 30A (24A agency de-rated) and terminates in a NEMA L5-30P locking plug.\u003c\/p\u003e\u003ch3\u003eDoes this PDU support remote network monitoring?\u003c\/h3\u003e\u003cp\u003eYes. It includes an integrated network card with SNMP support, allowing remote monitoring of output current across a data center rack fleet.\u003c\/p\u003e\u003ch3\u003eHow does the PDUMNV30LX mount in a rack, and will it fit my cabinet?\u003c\/h3\u003e\u003cp\u003eIt mounts vertically (0U) in the rack's side channel and spans 70 inches, so it is best suited to full-height 42U-class racks; confirm cabinet height before ordering.\u003c\/p\u003e\u003ch3\u003eCan this PDU integrate with network monitoring software already in use?\u003c\/h3\u003e\u003cp\u003eYes. Its SNMP support allows integration with common network and data center monitoring platforms.\u003c\/p\u003e\u003ch3\u003eIs the PDUMNV30LX appropriate for government data center installations?\u003c\/h3\u003e\u003cp\u003eYes. It is TAA compliant and UL listed, supporting government and public-sector procurement requirements.\u003c\/p\u003e\u003ch3\u003eWhat is the warranty on the Eaton PDUMNV30LX?\u003c\/h3\u003e\u003cp\u003eEaton Tripp Lite series PDUs typically carry a 2-year limited warranty. Contact Eaton or Creation Networks to confirm the specific warranty terms for this SKU.\u003c\/p\u003e\u003ch3\u003eWho can help verify this PDU fits my rack and power plan?\u003c\/h3\u003e\u003cp\u003eCreation Networks' AV\/IT team can confirm rack height, circuit capacity, and outlet requirements before you order.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":47865657458924,"sku":"PDUMNV30LX","price":399.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/PDUMNV30LX_C.jpg?v=1782802197","url":"https:\/\/creationnetworks.net\/products\/eaton-pdumnv30lx-metered-input-rack-pdu","provider":"Creation Networks","version":"1.0","type":"link"}