{"product_id":"eaton-pdumnh30hv-metered-input-rack-pdu","title":"Eaton PDUMNH30HV – 2U Monitored Rack PDU, 208\/230V","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe Eaton PDUMNH30HV is a 2U monitored rack PDU built for 208\/230V data center and colocation cabinet deployments that need network-based load monitoring across 16 outlets. With an integrated network card supporting SNMP, HTTP\/HTTPS, and SSH, it functions as a network-monitored PDU for data center racks where remote visibility into circuit loading matters as much as physical capacity. Its mixed C13\/C19 outlet layout makes it a strong fit for a 2U rack PDU installation serving both standard servers and higher-draw equipment such as blade chassis or rack-mount UPS units.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/PDUMNH30HV_C_ac3ef876-aa52-4c46-926d-00a86b917924.jpg?v=1786635922\" alt=\"Eaton PDUMNH30HV rack PDU\" style=\"max-width:100%;height:auto;\"\u003e\u003cp\u003eThe Eaton PDUMNH30HV is a 5.5kW (230V) \/ 5kW (208V) single-phase rack PDU designed for 208\/230V equipment racks in data centers and colocation environments. It occupies 2U of rack space, mounts horizontally, and terminates its 12-ft input cord in a NEMA L6-30P plug rated for 30A service (agency de-rated to 24A). On the output side it provides sixteen receptacles, split between twelve C13 and four C19 connectors, protected by two 20A breakers that each cover eight outlets, so a single fault does not take down the entire PDU.\u003c\/p\u003e\u003cp\u003eWhat separates the PDUMNH30HV from a purely local-metered PDU is its integrated WEBCARDLX network card, which supports HTTP, HTTPS, SNMP v1\/v2\/v3, SSH, Telnet, and NTP. This lets facilities and IT teams monitor output current remotely across a data center or colocation cabinet fleet, rather than relying on a technician reading a local display. For a network monitored PDU deployment where SNMP integration with existing DCIM or network management tools is required, this model is built for that use case.\u003c\/p\u003e\u003cp\u003eThe mixed C13\/C19 outlet configuration supports a wide range of equipment, from standard 1U servers and switches to blade enclosures, PDUs feeding downstream rack-mount UPS units, and higher-draw broadcast or AV processing gear. The PDUMNH30HV is UL Listed, CSA certified, RoHS compliant, and TAA compliant, making it appropriate for government data center racks as well as commercial colocation deployments. Reversible mounting ears support both 2-post and 4-post rack installations.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e16 Mixed C13\/C19 Outlets\u003c\/strong\u003e — Twelve C13 and four C19 receptacles support both standard IT equipment and higher-draw devices in the same PDU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated WEBCARDLX Network Card\u003c\/strong\u003e — Provides SNMP v1\/v2\/v3, HTTP\/HTTPS, SSH, Telnet, and NTP support for remote monitoring across the data center.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual 20A Branch Circuit Breakers\u003c\/strong\u003e — Two breakers each protect eight outlets, isolating faults so a single overload does not disable the full PDU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2U Horizontal Rack-Mount Design\u003c\/strong\u003e — Fits standard 2-post and 4-post racks with reversible mounting ears for flexible installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNEMA L6-30P Locking Input Plug\u003c\/strong\u003e — 30A-rated input (24A agency de-rated) with a 12-ft cord for stable connection to a 208\/230V circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Local Display\u003c\/strong\u003e — Reports output current across three loading segments for at-a-glance verification alongside remote monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTAA Compliant and UL Listed\u003c\/strong\u003e — Meets government procurement and safety certification requirements for data center deployment.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eData center\u003c\/li\u003e\n\u003cli\u003eColocation cabinet\u003c\/li\u003e\n\u003cli\u003eServer room\u003c\/li\u003e\n\u003cli\u003eNetwork closet\u003c\/li\u003e\n\u003cli\u003eGovernment space\u003c\/li\u003e\n\u003cli\u003eBroadcast studio\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208\/230V single-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Current\/Amperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30A max (agency de-rated to 24A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Plug\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNEMA L6-30P, 12-ft cord\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Receptacles\/Outlets\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12x IEC C13, 4x IEC C19 (16 total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Rating (kW\/VA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.5kW (230V) \/ 5kW (208V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\/Form Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2U rack-mount, horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitoring Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMonitored — integrated WEBCARDLX network card, SNMP v1\/v2\/v3, HTTP\/HTTPS, SSH, Telnet, NTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5\"W x 3.5\"H x 12.5\"D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed, CSA, NOM, RoHS, FCC Part 15 Class A, TAA compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-year limited warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eDoes the PDUMNH30HV support remote SNMP monitoring?\u003c\/h3\u003e\u003cp\u003eYes. It includes an integrated WEBCARDLX network card supporting SNMP v1\/v2\/v3, HTTP\/HTTPS, SSH, Telnet, and NTP for remote, network-based load monitoring.\u003c\/p\u003e\u003ch3\u003eWhat outlet types does this PDU provide?\u003c\/h3\u003e\u003cp\u003eThe PDUMNH30HV provides sixteen outlets total: twelve IEC C13 and four IEC C19 receptacles, supporting both standard IT equipment and higher-draw devices.\u003c\/p\u003e\u003ch3\u003eWhat input circuit does the PDUMNH30HV require?\u003c\/h3\u003e\u003cp\u003eIt requires a 208\/230V circuit terminating in a NEMA L6-30P receptacle, with input rated up to 30A (agency de-rated to 24A).\u003c\/p\u003e\u003ch3\u003eIs this PDU compatible with standard 2-post and 4-post racks?\u003c\/h3\u003e\u003cp\u003eYes. The PDUMNH30HV includes reversible mounting ears for installation in both 2-post and 4-post 19-inch equipment racks.\u003c\/p\u003e\u003ch3\u003eCan this PDU integrate with a DCIM or network management platform?\u003c\/h3\u003e\u003cp\u003eYes. Its SNMP and HTTP\/HTTPS support allows integration with common data center infrastructure management and network monitoring tools.\u003c\/p\u003e\u003ch3\u003eIs the PDUMNH30HV suitable for broadcast or AV equipment racks?\u003c\/h3\u003e\u003cp\u003eYes. Its C13\/C19 outlet mix and 5.5kW capacity support broadcast processing equipment and AV rack gear alongside standard IT hardware.\u003c\/p\u003e\u003ch3\u003eWhat is the warranty on the Eaton PDUMNH30HV?\u003c\/h3\u003e\u003cp\u003eThe PDUMNH30HV carries a 2-year limited warranty from Eaton.\u003c\/p\u003e\u003ch3\u003eWho can help plan the circuit and rack layout before I order?\u003c\/h3\u003e\u003cp\u003eCreation Networks' AV\/IT team can review your power and rack layout to confirm the PDUMNH30HV fits your installation before purchase.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":47865658147052,"sku":"PDUMNH30HV","price":799.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/PDUMNH30HV_C_ac3ef876-aa52-4c46-926d-00a86b917924.jpg?v=1786635922","url":"https:\/\/creationnetworks.net\/products\/eaton-pdumnh30hv-metered-input-rack-pdu","provider":"Creation Networks","version":"1.0","type":"link"}