{"product_id":"eaton-pdumh20hvnet-pdu-switched-200v-240v-20a-c13-8-outlet-l6-20p-horizontal-1urm","title":"Eaton PDUMH20HVNET – Switched 1U PDU, 200-240V 20A","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe Eaton PDUMH20HVNET is a single-phase switched PDU that gives data center and server room operators advanced remote control over 8 C13 outlets on a 200-240V, 20A circuit. This 1U horizontal rack PDU can turn on, turn off, recycle, or lock out power to each individual outlet, monitor site electrical conditions, and report output power consumption remotely. Its built-in LX Platform network interface makes it a strong fit for managed data centers running remote reboot and load monitoring workflows.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eIndividually switched outlets on the PDUMH20HVNET can be controlled in real time to remotely reboot unresponsive network hardware, or custom programmed for user-defined power-up and power-down sequences that ensure proper startup of interdependent IT systems and prevent inrush-related overloads as equipment is first energized. Unused outlets can be electronically locked off to prevent the connection of unauthorized hardware, a useful control in shared or colocation environments. PDU output current consumption in amps is continuously displayed locally via a visual meter, and remotely via the web\/network interface, providing an early warning of potential overloads before critical IT mains or branch breakers trip. The built-in LX Platform network management interface card provides a Java-free, HTML5-based interface for full remote access, supporting PDU status monitoring and email notifications via secure web browser, SNMP, telnet, or SSH. It supports 10\/100 Mbps auto-sensing for optimum communication with an Ethernet network, and protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP, and NTP. Optional EnviroSense2 modules, sold separately, provide a variety of environmental monitoring capabilities for racks that also need temperature and humidity visibility. With eight C13 outlets fed from an L6-20P input, this 1U horizontal rack PDU is designed for data centers running 208\/240V equipment that need individual outlet-level control and remote monitoring.\u003c\/p\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/pdumh20hvnet.jpg?v=1786674018\" alt=\"Eaton PDUMH20HVNET 1U switched PDU with network interface\"\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndividually Switched Outlets\u003c\/strong\u003e — Remotely turn on, turn off, recycle, or lock out power to each of the eight C13 outlets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgrammable Power-Up Sequencing\u003c\/strong\u003e — User-defined startup order and intervals prevent inrush overloads and ensure proper equipment sequencing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocal and Remote Current Display\u003c\/strong\u003e — Output current is shown locally via visual meter and remotely through the network interface for early overload warning.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-In LX Platform Interface\u003c\/strong\u003e — Java-free, HTML5-based remote access supports monitoring and notifications via web browser, SNMP, telnet, or SSH.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutlet Lockout\u003c\/strong\u003e — Unused outlets can be electronically locked off to prevent connection of unauthorized hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Monitoring Ready\u003c\/strong\u003e — Optional EnviroSense2 modules add temperature and humidity monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eData center\u003c\/li\u003e\n\u003cli\u003eServer room\u003c\/li\u003e\n\u003cli\u003eColocation facility\u003c\/li\u003e\n\u003cli\u003eNetwork closet\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e200-240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Current\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Plug\u003c\/td\u003e\n\u003ctd\u003eL6-20P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlets\u003c\/td\u003e\n\u003ctd\u003e8 x C13, individually switched\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Interface\u003c\/td\u003e\n\u003ctd\u003eBuilt-in LX Platform, HTML5\/SNMP\/SSH\/telnet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003e1U rack mount, horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eCan I reboot a single unresponsive server outlet without powering down the whole rack?\u003c\/h3\u003e\u003cp\u003eYes. Each of the eight C13 outlets can be switched independently, so you can remotely recycle power to a single unresponsive device without affecting the others.\u003c\/p\u003e\u003ch3\u003eHow does the PDU help prevent inrush-related overloads on startup?\u003c\/h3\u003e\u003cp\u003eIt supports user-programmable outlet startup sequencing, allowing you to define the order and interval in which outlets power on so interdependent systems start correctly and avoid a simultaneous inrush current spike.\u003c\/p\u003e\u003ch3\u003eCan unused outlets be secured against unauthorized equipment?\u003c\/h3\u003e\u003cp\u003eYes. Unused outlets can be electronically locked off, preventing connection of unauthorized hardware to those ports.\u003c\/p\u003e\u003ch3\u003eWhat network protocols does the built-in interface support?\u003c\/h3\u003e\u003cp\u003eThe interface supports HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP, and NTP for integration with common data center monitoring tools.\u003c\/p\u003e\u003ch3\u003eDoes this PDU support environmental monitoring out of the box?\u003c\/h3\u003e\u003cp\u003eNot by default, but the optional EnviroSense2 module, sold separately, adds environmental monitoring capability to this unit.\u003c\/p\u003e\u003ch3\u003eWhat warranty does Eaton provide on this unit?\u003c\/h3\u003e\u003cp\u003eEaton backs this unit with its standard manufacturer warranty; contact Creation Networks for the current term and any extended coverage options.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":48159674859756,"sku":"PDUMH20HVNET","price":818.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/pdumh20hvnet.jpg?v=1786674018","url":"https:\/\/creationnetworks.net\/products\/eaton-pdumh20hvnet-pdu-switched-200v-240v-20a-c13-8-outlet-l6-20p-horizontal-1urm","provider":"Creation Networks","version":"1.0","type":"link"}