{"product_id":"eaton-pdumh15hvatnet-2-4kw-single-phase-switched-automatic-transfer-switch-pdu-two-200-240v","title":"Eaton PDUMH15HVATNET – 2.4kW Switched ATS PDU, Dual Input","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe Eaton PDUMH15HVATNET is a 2.4kW single-phase switched PDU with automatic transfer switching (ATS), built for data centers, server rooms, and network closets that need redundant A\/B power for single-corded equipment. With dual 200-240V inputs and millisecond-level failover between sources, it keeps network devices powered through a primary source failure. This 1U switched PDU also provides remote outlet control and monitoring through Eaton's LX Platform interface.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eThis 2-2.4kW single-phase ATS PDU has primary and secondary inputs for power redundancy. Recommended for data centers, server rooms, and network closets, this 1U switched power distribution unit enables redundant A\/B power for network devices with single power cords. Dual 12-foot input cords with C14 plugs connect to separate primary and secondary mains circuits, backup generators, UPS systems, or utility power grids. Plug-lock insert sleeves are included to prevent connected cords from becoming accidentally dislodged. The PDUMH15HVATNET constantly evaluates the power quality of both input sources and maintains continuous power to all outlets as derived from the primary source. Dynamic solid-state automatic transfer switching allows the IEC C13 PDU to switch to the secondary source within 2-5 milliseconds should the primary source fail or become unstable, ensuring connected equipment operates without interruption; an onboard ATS processor prevents switching if the secondary source is unavailable or of lower quality than the primary source. Eight switched C13 outlets, with two additional unswitched C13 outlets, are subject to advanced network control and remote power monitoring, including the ability to turn on, turn off, reboot, or lock out power to each outlet, reducing the frequency of on-site visits and lowering total cost of ownership. A front-panel digital load meter displays total PDU output current in amps, and LEDs indicate on\/off status of individual outlets and power status of primary and secondary inputs, while an input-voltage select switch lets you toggle between high (220, 230, or 240V) or low (200 or 208V) voltage. The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet, or SSH, supporting 10\/100 Mbps auto-sensing Ethernet communication, with optional EnviroSense2 modules available for environmental monitoring. The Auto Probe feature (firmware 15.5.2 and greater) checks connectivity status of networked devices and can automatically reboot an outlet, set SNMP traps or OIDs, or trigger scripts through the Tripp Lite PowerAlert Network Shutdown Agent. This ATS PDU mounts in 1U of space in a 19-inch rack or rack cabinet using included brackets and hardware, and is TAA-compliant, making it eligible for GSA Schedule and other federal procurement contracts.\u003c\/p\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/pdumh15hvatnet.jpg?v=1786673906\" alt=\"Eaton PDUMH15HVATNET automatic transfer switch PDU with dual inputs\"\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic Transfer Switching\u003c\/strong\u003e — Switches to the secondary power source within 2-5 milliseconds if the primary source fails or degrades.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Primary\/Secondary Inputs\u003c\/strong\u003e — Two 12-foot C14 input cords support redundant A\/B power for single-corded network devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e8 Switched + 2 Unswitched C13 Outlets\u003c\/strong\u003e — Switched outlets allow remote reboot, on\/off, and lockout control per outlet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLX Platform Remote Access\u003c\/strong\u003e — Java-free HTML5 interface for browser, SNMP, telnet, or SSH-based monitoring and control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput-Voltage Select Switch\u003c\/strong\u003e — Toggles between high (220-240V) and low (200-208V) voltage input ranges.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto Probe Device Management\u003c\/strong\u003e — Automatically checks device connectivity and takes configured actions, such as outlet reboot, on failure to respond.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTAA Compliant\u003c\/strong\u003e — Eligible for GSA Schedule and other federal procurement contracts.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eData centers requiring A\/B power redundancy\u003c\/li\u003e\n\u003cli\u003eServer rooms with single-corded network devices\u003c\/li\u003e\n\u003cli\u003eNetwork closets needing automatic failover protection\u003c\/li\u003e\n\u003cli\u003eGovernment and federal facility data centers\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePDUMH15HVATNET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity\u003c\/td\u003e\n\u003ctd\u003e2-2.4kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eSingle-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e200-240V (dual-range select switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlets\u003c\/td\u003e\n\u003ctd\u003e10 total (8 switched C13, 2 unswitched C13)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Plugs\u003c\/td\u003e\n\u003ctd\u003eDual C14 (primary and secondary), 12 ft cords\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Time\u003c\/td\u003e\n\u003ctd\u003e2-5 milliseconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003e1U rack-mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement\u003c\/td\u003e\n\u003ctd\u003eLX Platform (HTML5, SNMP, telnet, SSH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eTAA-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eHow fast does this PDU switch to the secondary power source?\u003c\/h3\u003e\u003cp\u003eThe solid-state automatic transfer switch completes the switch within 2-5 milliseconds if the primary source fails or becomes unstable.\u003c\/p\u003e\u003ch3\u003eCan I use this with single-corded equipment?\u003c\/h3\u003e\u003cp\u003eYes, the ATS design is specifically built to give single-corded network devices redundant A\/B power without requiring dual power supplies.\u003c\/p\u003e\u003ch3\u003eWhat input sources are supported?\u003c\/h3\u003e\u003cp\u003eThe dual 12-foot C14 input cords can connect to separate mains circuits, backup generators, UPS systems, or utility power grids.\u003c\/p\u003e\u003ch3\u003eCan I control individual outlets remotely?\u003c\/h3\u003e\u003cp\u003eYes, the 8 switched C13 outlets support remote on\/off, reboot, and lockout control through the LX Platform interface; 2 additional C13 outlets are unswitched.\u003c\/p\u003e\u003ch3\u003eIs this PDU eligible for federal procurement?\u003c\/h3\u003e\u003cp\u003eYes, it is TAA-compliant, making it eligible for GSA Schedule and other federal procurement contracts.\u003c\/p\u003e\u003ch3\u003eWhat warranty does Eaton provide on this PDU?\u003c\/h3\u003e\u003cp\u003eEaton backs this unit with its standard manufacturer warranty; contact Creation Networks for the current term and any extended coverage options.\u003c\/p\u003e\u003ch3\u003eCan Creation Networks help design an A\/B power redundancy scheme with this PDU?\u003c\/h3\u003e\u003cp\u003eYes, our team can help plan primary\/secondary source wiring and outlet allocation for your redundancy requirements.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":48159671746796,"sku":"PDUMH15HVATNET","price":1087.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/pdumh15hvatnet.jpg?v=1786673906","url":"https:\/\/creationnetworks.net\/products\/eaton-pdumh15hvatnet-2-4kw-single-phase-switched-automatic-transfer-switch-pdu-two-200-240v","provider":"Creation Networks","version":"1.0","type":"link"}