{"product_id":"eaton-pdub151u-100-125v-12a-single-phase-hot-swap-pdu-with-manual-bypass-6-nema-5-15r-outlets-2-5-15p-inputs-1u-rack-wall","title":"Eaton PDUB151U – 100-125V Hot-Swap Bypass PDU, 1U","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe Eaton PDUB151U is a 100-125V, 12A single-phase hot-swap PDU with manual bypass, designed to keep mission-critical data center equipment powered during scheduled UPS maintenance or replacement. Working alongside an existing UPS system, this 1U rack or wall-mount PDU lets technicians manually transfer connected equipment to utility power via a bypass switch, avoiding the downtime that a full power-down would otherwise require.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eScheduled UPS maintenance is often unavoidable in a data center, but powering down connected equipment to perform it is rarely acceptable when uptime is mission-critical. The PDUB151U solves this by allowing staff to manually transfer connected equipment to utility power through the PDU's bypass switch, permitting UPS maintenance or replacement with no interruption to running equipment. The unit provides six NEMA 5-15R outlets for connecting servers, switches, or other rack-mounted devices, and accepts dual NEMA 5-15P inputs so it can draw power from both the UPS output and a separate utility or bypass source. Built for 100-125V single-phase environments at 12A, the PDUB151U installs into 1U of a standard 19-inch rack or can be wall-mounted, giving integrators flexibility depending on available space in the equipment room. This hot-swap bypass PDU is recommended for data centers and other mission-critical environments where continuous 24\/7\/365 uptime during UPS maintenance windows is a requirement rather than a nice-to-have.\u003c\/p\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/pdub151u.jpg?v=1786673995\" alt=\"Eaton PDUB151U 1U hot-swap bypass PDU with manual bypass switch\"\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManual Bypass Switch\u003c\/strong\u003e — Transfers connected equipment to utility power so UPS maintenance or replacement can occur without downtime.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual NEMA 5-15P Inputs\u003c\/strong\u003e — Separate inputs allow the PDU to draw from both a UPS output and a bypass or utility source.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e6 NEMA 5-15R Outlets\u003c\/strong\u003e — Standard outlets connect servers, switches, and other rack-mounted equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1U Rack or Wall Mount\u003c\/strong\u003e — Compact housing installs into a standard 19-inch rack or mounts to a wall depending on available space.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous Uptime Design\u003c\/strong\u003e — Built to keep mission-critical equipment powered 24\/7\/365 through planned maintenance windows.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eData centers\u003c\/li\u003e\n\u003cli\u003eServer rooms\u003c\/li\u003e\n\u003cli\u003eColocation facilities\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e12A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e100-125V, single-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connectors\u003c\/td\u003e\n\u003ctd\u003e2 x NEMA 5-15P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Outlets\u003c\/td\u003e\n\u003ctd\u003e6 x NEMA 5-15R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003e1U rack or wall mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Type\u003c\/td\u003e\n\u003ctd\u003eManual bypass (hot-swap)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the purpose of the manual bypass switch?\u003c\/h3\u003e\u003cp\u003eThe bypass switch allows connected equipment to be transferred to utility power so the associated UPS can undergo maintenance or replacement without interrupting equipment operation.\u003c\/p\u003e\u003ch3\u003eHow many power sources connect to this PDU?\u003c\/h3\u003e\u003cp\u003eThe PDUB151U accepts two NEMA 5-15P inputs, typically one from the UPS output and one from a bypass or utility source.\u003c\/p\u003e\u003ch3\u003eHow is the PDUB151U mounted?\u003c\/h3\u003e\u003cp\u003eIt installs into 1U of a standard 19-inch rack or can be mounted to a wall, depending on available equipment room space.\u003c\/p\u003e\u003ch3\u003eIs the bypass switch automatic or manual?\u003c\/h3\u003e\u003cp\u003eThe PDUB151U uses a manual bypass switch, requiring a technician to initiate the transfer to utility power.\u003c\/p\u003e\u003ch3\u003eWhat environments is this PDU designed for?\u003c\/h3\u003e\u003cp\u003eIt is designed for mission-critical data center and server room environments where continuous uptime during UPS maintenance is required.\u003c\/p\u003e\u003ch3\u003eWhat warranty applies to this unit?\u003c\/h3\u003e\u003cp\u003eEaton backs this unit with its standard manufacturer warranty; contact Creation Networks for the current term and any extended coverage options.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":48159674204396,"sku":"PDUB151U","price":262.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/pdub151u.jpg?v=1786673995","url":"https:\/\/creationnetworks.net\/products\/eaton-pdub151u-100-125v-12a-single-phase-hot-swap-pdu-with-manual-bypass-6-nema-5-15r-outlets-2-5-15p-inputs-1u-rack-wall","provider":"Creation Networks","version":"1.0","type":"link"}