{"product_id":"eaton-pdu3mv6l2120-5-7kw-3-phase-local-metered-pdu-208-120v-outlets-36-c13-6-c19-6-5-15-20r-l21-20p-6-ft-1-83-m-cord-0u-vertical-taa","title":"Eaton PDU3MV6L2120 – 5.7kW 3-Phase Metered PDU, 0U","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe Eaton PDU3MV6L2120 is a 5.7kW 3-phase local metered PDU delivering 208\/120V power across 36 C13, 6 C19, and 6 NEMA 5-15\/20R outlets, built into a 0U vertical, TAA-compliant chassis with an L21-20P input and a 6 ft. cord. It is designed for rack-mount, multi-outlet power distribution in data center and server room environments that need three-phase input with real-time local load metering. Three built-in digital meters give facilities managers phase-by-phase visibility into current draw, an important capability for balancing loads across three-phase rack circuits.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eThree-phase rack PDUs require careful load balancing across phases to avoid overloading any single leg, and the PDU3MV6L2120 supports this with real-time local reporting of current levels in amps via a set of three built-in digital meters, one per phase. This visual monitoring capability helps technicians preserve proper load balance and prevent circuit overloads as additional equipment is added to the rack over time. The PDU delivers 208\/120V power distribution across a large outlet count of 36 C13, 6 C19, and 6 NEMA 5-15\/20R receptacles, giving integrators the flexibility to power a wide mix of rack-mount servers, networking equipment, and standard NEMA-plug devices from a single vertical 0U unit. Reliable rackmount multi-outlet power distribution is delivered from any protected UPS, generator, or mains input power source through the L21-20P input plug and 6 ft. (1.83 m) cord. The rugged all-metal housing and included mounting accessories support secure rackmount installation in a standard 19-inch rack, and TAA compliance makes this PDU eligible for GSA Schedule and other federal procurement contracts. The combination of three-phase input, high outlet density, and local phase metering makes the PDU3MV6L2120 well suited for data center racks and server rooms that need to distribute power across a large number of devices while keeping each phase properly balanced.\u003c\/p\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/pdu3mv6l2120.jpg?v=1786673967\" alt=\"Eaton PDU3MV6L2120 3-phase local metered PDU with 36 C13, 6 C19 and 6 NEMA outlets\"\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3-Phase Local Load Metering\u003c\/strong\u003e — three built-in digital meters report current per phase to help maintain load balance and prevent overloads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Density Outlet Mix\u003c\/strong\u003e — 36 C13, 6 C19, and 6 NEMA 5-15\/20R outlets support a wide variety of rack and standard-plug equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0U Vertical Form Factor\u003c\/strong\u003e — mounts vertically in a 19-inch rack without consuming horizontal U space.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eL21-20P Input Plug\u003c\/strong\u003e — connects to a three-phase power source, UPS, or generator via the included 6 ft. cord.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRugged All-Metal Housing\u003c\/strong\u003e — built for secure rackmount installation with included mounting accessories.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTAA-Compliant\u003c\/strong\u003e — eligible for GSA Schedule and other federal procurement contracts.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eData center racks requiring three-phase power distribution with local metering\u003c\/li\u003e\n\u003cli\u003eServer rooms with a large mix of C13, C19, and NEMA-plug equipment\u003c\/li\u003e\n\u003cli\u003eColocation cabinets needing 0U vertical PDU installation\u003c\/li\u003e\n\u003cli\u003eGovernment and federal facility racks requiring TAA-compliant power distribution\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Rating\u003c\/td\u003e\n\u003ctd\u003e5.7kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003e3-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e208\/120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Count\u003c\/td\u003e\n\u003ctd\u003e36 C13, 6 C19, 6 NEMA 5-15\/20R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connector\u003c\/td\u003e\n\u003ctd\u003eNEMA L21-20P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCord Length\u003c\/td\u003e\n\u003ctd\u003e6 ft. (1.83 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003e0U Vertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetering\u003c\/td\u003e\n\u003ctd\u003e3 built-in digital meters (per-phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eTAA-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eHow does the per-phase metering help with load balancing?\u003c\/h3\u003e\u003cp\u003eThree built-in digital meters report current draw for each phase independently, giving technicians the visibility needed to keep loads balanced as equipment is added to the rack.\u003c\/p\u003e\u003ch3\u003eWhat outlet types are available on this PDU?\u003c\/h3\u003e\u003cp\u003eThe unit provides 36 C13, 6 C19, and 6 NEMA 5-15\/20R outlets to accommodate a wide range of rack and standard-plug equipment.\u003c\/p\u003e\u003ch3\u003eDoes this PDU require a three-phase electrical circuit?\u003c\/h3\u003e\u003cp\u003eYes, the L21-20P input plug is designed for a three-phase power source such as a facility mains circuit, generator, or UPS.\u003c\/p\u003e\u003ch3\u003eIs this PDU eligible for government procurement?\u003c\/h3\u003e\u003cp\u003eYes, the PDU3MV6L2120 is TAA-compliant, making it eligible for GSA Schedule and other federal procurement contracts.\u003c\/p\u003e\u003ch3\u003eHow is this PDU mounted in a rack?\u003c\/h3\u003e\u003cp\u003eIt mounts vertically as a 0U unit using the included rackmount mounting accessories and rugged all-metal housing.\u003c\/p\u003e\u003ch3\u003eWhat is the warranty on this product?\u003c\/h3\u003e\u003cp\u003eEaton backs this unit with its standard manufacturer warranty; contact Creation Networks for the current term and any extended coverage options.\u003c\/p\u003e\u003ch3\u003eCan Creation Networks help plan phase balancing for a new rack deployment?\u003c\/h3\u003e\u003cp\u003eYes, our team can help review your equipment's power draw to plan an appropriate three-phase load distribution across this PDU.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":48159673319660,"sku":"PDU3MV6L2120","price":641.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/pdu3mv6l2120.jpg?v=1786673967","url":"https:\/\/creationnetworks.net\/products\/eaton-pdu3mv6l2120-5-7kw-3-phase-local-metered-pdu-208-120v-outlets-36-c13-6-c19-6-5-15-20r-l21-20p-6-ft-1-83-m-cord-0u-vertical-taa","provider":"Creation Networks","version":"1.0","type":"link"}