{"product_id":"eaton-pdu3mv6h50-12-6kw-3-phase-local-metered-pdu-208v-outlets-36-c13-9-c19-hubbell-50a-cs8365c-6-ft","title":"Eaton PDU3MV6H50 – 12.6kW 3-Phase Local Metered PDU","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe Eaton PDU3MV6H50 is a 3-phase local metered rack PDU delivering 12.6kW at 208V through 45 outlets — 36 C13 and 9 C19 — for high-density rack power distribution. Local digital metering lets on-site staff read real-time current draw directly at the PDU, making it a solid fit for data centers and server rooms that need visual load monitoring without a full network management layer. The Hubbell 50A CS8365C input and 6-foot cord suit facilities already wired for locking 3-phase receptacles. This PDU is well suited to integrators standardizing on 3-phase rack power for dense server or network equipment deployments.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eThis 3-phase metered PDU offers real-time local reporting of current levels in amps through a set of three built-in digital meters, enabling visual monitoring of PDU current levels to preserve proper load balancing and prevent circuit overloads as additional equipment is added to a rack. It provides reliable rackmount multi-outlet power distribution from any protected UPS, generator, or mains input power source, with 45 total outlets — 36 C13 and 9 C19 — to accommodate a wide mix of servers, switches, and network appliances on a single 3-phase circuit. The unit is rated 208V and delivers up to 12.6kW of capacity, making it appropriate for dense server rack loads in enterprise data centers and server rooms. A Hubbell 50A CS8365C locking input plug on a 6-foot cord connects the PDU to a compatible 3-phase power source, and the locking design helps prevent accidental disconnection in a busy rack environment. High-quality construction includes a rugged all-metal housing and secure rackmount installation hardware, giving integrators a durable option for permanent rack PDU deployments. Because metering is local rather than networked, staff can read load levels directly from the unit during routine site visits or maintenance windows without needing a separate monitoring platform.\u003c\/p\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/pdu3mv6h50.jpg?v=1786673861\" alt=\"Eaton PDU3MV6H50 3-phase local metered rack PDU\"\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e45 Outlets (36 C13, 9 C19)\u003c\/strong\u003e — A high outlet count on a single 3-phase circuit accommodates dense mixes of servers, switches, and network equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree Digital Load Meters\u003c\/strong\u003e — Local, real-time current readings per phase help prevent overloads as equipment is added over time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e12.6kW at 208V 3-Phase\u003c\/strong\u003e — Delivers substantial power capacity suited to dense rack loads in enterprise data centers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHubbell 50A CS8365C Locking Input\u003c\/strong\u003e — A 6-foot locking cord connects securely to compatible 3-phase power sources, UPS systems, or generators.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRugged All-Metal Housing\u003c\/strong\u003e — Built for durable, long-term rackmount installation in commercial data center environments.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eData center\u003c\/li\u003e\n\u003cli\u003eServer room\u003c\/li\u003e\n\u003cli\u003eColocation facility\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Capacity\u003c\/td\u003e\n\u003ctd\u003e12.6kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e208V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003e3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlets\u003c\/td\u003e\n\u003ctd\u003e36 x C13, 9 x C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Plug\u003c\/td\u003e\n\u003ctd\u003eHubbell 50A CS8365C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCord Length\u003c\/td\u003e\n\u003ctd\u003e6 ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetering\u003c\/td\u003e\n\u003ctd\u003eLocal digital, per-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eDoes this PDU require networked monitoring software?\u003c\/h3\u003e\u003cp\u003eNo, the PDU3MV6H50 uses local digital ammeters that display current draw directly on the unit, so no separate monitoring software is required to read load levels.\u003c\/p\u003e\u003ch3\u003eWhat input connector does this PDU use?\u003c\/h3\u003e\u003cp\u003eIt uses a Hubbell 50A CS8365C locking plug on a 6-foot cord, designed for facilities wired with compatible 3-phase locking receptacles.\u003c\/p\u003e\u003ch3\u003eHow many devices can this PDU support?\u003c\/h3\u003e\u003cp\u003eIt provides 45 total outlets — 36 C13 and 9 C19 — allowing a wide mix of servers, switches, and network appliances to be powered from a single 3-phase circuit.\u003c\/p\u003e\u003ch3\u003eIs this PDU suitable for high-density server racks?\u003c\/h3\u003e\u003cp\u003eYes, its 12.6kW capacity at 208V 3-phase and high outlet count make it well suited for dense server and network equipment loads in enterprise data centers.\u003c\/p\u003e\u003ch3\u003eCan this PDU connect to a UPS system?\u003c\/h3\u003e\u003cp\u003eYes, it is designed to connect to any protected UPS, generator, or mains power source that provides a compatible 3-phase circuit.\u003c\/p\u003e\u003ch3\u003eWhat warranty applies to this PDU?\u003c\/h3\u003e\u003cp\u003eEaton backs this unit with its standard manufacturer warranty; contact Creation Networks for the current term and any extended coverage options.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":48159670698220,"sku":"PDU3MV6H50","price":1074.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/pdu3mv6h50.jpg?v=1786673861","url":"https:\/\/creationnetworks.net\/products\/eaton-pdu3mv6h50-12-6kw-3-phase-local-metered-pdu-208v-outlets-36-c13-9-c19-hubbell-50a-cs8365c-6-ft","provider":"Creation Networks","version":"1.0","type":"link"}