{"product_id":"eaton-pdu3evnr6h50a-metered-input-rack-pdu","title":"Eaton PDU3EVNR6H50A – 18-Outlet ePDU G3 Metered PDU","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Eaton PDU3EVNR6H50A is a 208V 3-phase metered input rack PDU from the ePDU G3 platform, purpose-built for server room and colocation cabinet installations where higher-current C19 equipment is common. This Eaton ePDU G3 metered PDU combines 6 C13 and 12 C19 outlets in a 0U vertical unit, supporting rack PDU installation for mixed server, storage, and network loads. Integrators specifying a 3-phase metered PDU for data center or colocation cabinet builds use this model where load monitoring is required without the added complexity of outlet switching.\u003c\/p\u003e\n\n\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/PDU3EVNR6H50A_0_6e872452-29f0-495a-80b2-c265dc4c7af4.jpg?v=1786636912\" alt=\"Eaton PDU3EVNR6H50A rack PDU\" style=\"max-width:100%;height:auto;\"\u003e\u003c\/p\u003e\n\u003cp\u003eThe Eaton PDU3EVNR6H50A is rated for 208V 3-phase input at 40A, delivering up to 14.4 kW through 18 total outlets: 6 IEC C13 and 12 IEC C19 receptacles. Input connects through a Hubbell CS8365C locking connector on a 6-foot cord, a configuration commonly specified in North American data center and colocation electrical infrastructure. The higher proportion of C19 outlets relative to C13 makes this PDU well suited to cabinets with storage arrays, blade enclosures, and other higher-draw equipment alongside standard servers.\u003c\/p\u003e\n\u003cp\u003eThe unit includes an LX platform interface supporting compatibility with Eaton's PowerAlert Device Manager, allowing facilities and IT teams to monitor input load remotely as part of a broader server room or data center power monitoring strategy. This is particularly relevant for commercial AV\/IT integrators who need visibility into circuit loading across multiple cabinets without manually checking each PDU at the rack. The 0U vertical mounting profile runs the height of the rack frame, keeping the outlet count fully accessible without using horizontal rack unit space.\u003c\/p\u003e\n\u003cp\u003eWhen planning a rack PDU installation with the PDU3EVNR6H50A, integrators should confirm that facility electrical service supports 208V 3-phase circuits terminated with a CS8365C receptacle, and that the 6:12 ratio of C13 to C19 outlets matches the cabinet's equipment mix, since this model is optimized for loads skewed toward C19-terminated devices rather than a C13-only server stack.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e18 Total Outlets\u003c\/strong\u003e — 6 C13 and 12 C19 receptacles are configured for cabinets with a higher proportion of storage, blade, and other C19-terminated equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e208V 3-Phase, 14.4 kW Capacity\u003c\/strong\u003e — The unit delivers substantial power capacity suited to dense server room and colocation cabinet loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHubbell CS8365C Input Connector\u003c\/strong\u003e — A locking industrial connector common to North American data center electrical infrastructure improves connection security.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLX Platform Monitoring Interface\u003c\/strong\u003e — Compatibility with PowerAlert Device Manager supports remote load monitoring across a facility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0U Vertical Mounting\u003c\/strong\u003e — Vertical installation preserves horizontal rack unit space for active equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Certification Compliance\u003c\/strong\u003e — UL 60950-1, CSA, FCC Class A, RoHS, and NOM certifications support commercial and regulated facility deployments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eData center\u003c\/li\u003e\n\u003cli\u003eColocation cabinet\u003c\/li\u003e\n\u003cli\u003eServer room\u003c\/li\u003e\n\u003cli\u003eNetwork closet\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208V, 3-phase, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Current\/Amperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Plug\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHubbell CS8365C, 6 ft cord\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Receptacles\/Outlets\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 x IEC C13, 12 x IEC C19 (18 total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Rating (kW\/VA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14.4 kW max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\/Form Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0U, vertical rack-mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitoring Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMetered (LX interface, PowerAlert Device Manager compatible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 70 in (H) x 2.17 in (W) x 2.86 in (D); 20.01 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 60950-1, CSA Std. C22.2, FCC Class A, RoHS, NOM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContact Eaton\/Creation Networks for warranty terms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat electrical circuit does the PDU3EVNR6H50A require?\u003c\/h3\u003e\n\u003cp\u003eIt requires a 208V, 3-phase circuit rated for 40A, terminated with a Hubbell CS8365C locking receptacle. Verify this matches your facility's electrical infrastructure before ordering.\u003c\/p\u003e\n\u003ch3\u003eWhat kind of equipment is this PDU best suited for?\u003c\/h3\u003e\n\u003cp\u003eWith 12 C19 and only 6 C13 outlets, it is best suited for cabinets with a higher proportion of storage arrays, blade servers, and other C19-terminated equipment rather than a C13-only server stack.\u003c\/p\u003e\n\u003ch3\u003eCan this PDU be integrated into an existing power monitoring system?\u003c\/h3\u003e\n\u003cp\u003eYes. The LX platform interface supports compatibility with Eaton's PowerAlert Device Manager for remote load monitoring alongside other Eaton power devices.\u003c\/p\u003e\n\u003ch3\u003eDoes the PDU3EVNR6H50A support individual outlet control?\u003c\/h3\u003e\n\u003cp\u003eNo. This is a metered input model, reporting total load without per-outlet switching. Eaton's switched or managed ePDU G3 models provide outlet-level control if needed.\u003c\/p\u003e\n\u003ch3\u003eHow is this PDU mounted in the rack?\u003c\/h3\u003e\n\u003cp\u003eIt mounts vertically in a 0U configuration along the rack frame, which keeps all 18 outlets accessible without using horizontal rack unit space.\u003c\/p\u003e\n\u003ch3\u003eWhat warranty applies to this product?\u003c\/h3\u003e\n\u003cp\u003eSpecific warranty term details for this model were not published by the manufacturer at time of writing. Contact Eaton or Creation Networks for current terms.\u003c\/p\u003e\n\u003ch3\u003eCan Creation Networks help confirm compatibility with my existing rack infrastructure?\u003c\/h3\u003e\n\u003cp\u003eYes. Creation Networks can review your cabinet's electrical service and equipment mix to confirm the PDU3EVNR6H50A fits your server room or colocation cabinet deployment.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":47865656180972,"sku":"PDU3EVNR6H50A","price":1449.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/PDU3EVNR6H50A_0_6e872452-29f0-495a-80b2-c265dc4c7af4.jpg?v=1786636912","url":"https:\/\/creationnetworks.net\/products\/eaton-pdu3evnr6h50a-metered-input-rack-pdu","provider":"Creation Networks","version":"1.0","type":"link"}