{"product_id":"eaton-mda3f34upx00000-edgeready-micro-data-center-34u-2-6-kva-ups-systems-n-n-network-management-and-dual-pdus-208-240v-or-230v-assembled-tested-unit","title":"Eaton MDA3F34UPX00000 – 34U EdgeReady Micro Data Center","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe Eaton MDA3F34UPX00000 is a fully assembled and tested 34U EdgeReady micro data center built for organizations that need a self-contained edge computing rack enclosure without a multi-week custom build. It ships pre-integrated with two 6 kVA UPS systems in an N+N redundant configuration, dual metered PDUs, and network management, making it a turnkey dual UPS N+N micro data center enclosure for distributed IT and AV infrastructure deployments. This is a fit for branch offices, retail locations, and remote facilities that need commercial-grade edge computing rack enclosure capacity delivered ready to power on. Because the unit arrives assembled and tested, integrators avoid the labor and coordination typically required to rack, wire, and commission a UPS and PDU setup on-site.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/mda3f34upx00000.jpg?v=1786678453\" alt=\"Eaton MDA3F34UPX00000 34U EdgeReady micro data center\" style=\"max-width:100%;height:auto;\"\u003e\u003cp\u003eThe MDA3F34UPX00000 is built on Tripp Lite's EdgeReady platform, which ships fully assembled and tested three business days after order receipt rather than requiring weeks of custom integration. The 34U rack enclosure houses two 6 kVA UPS systems in an N+N redundant configuration, so a failure or maintenance event on one UPS does not take down the protected load, a critical requirement for edge sites without on-site IT staff. Dual metered PDUs provide power distribution and monitoring for the racked equipment, giving remote administrators visibility into load and consumption without a site visit. Network management is built into the assembled unit, allowing centralized monitoring of UPS status, environmental conditions, and power events across a distributed fleet of edge deployments. This 34U pre-assembled micro data center configuration includes toolless blanking panels to maintain proper airflow across unused rack space, which matters for equipment density and thermal management in a compact enclosure. For organizations standardizing edge or branch infrastructure across multiple sites, the assembled MDA3F34UPX00000 reduces variability between installations compared to field-assembled rack, UPS, and PDU components sourced separately.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eN+N Redundant UPS Configuration\u003c\/strong\u003e — Two 6 kVA UPS systems provide power redundancy so a single UPS failure does not interrupt protected loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e34U Rack Capacity\u003c\/strong\u003e — Provides substantial equipment mounting space within a single self-contained enclosure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Metered PDUs\u003c\/strong\u003e — Delivers power distribution with load metering for remote visibility into rack power consumption.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Network Management\u003c\/strong\u003e — Enables centralized monitoring of UPS and environmental status across distributed deployments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAssembled and Tested Before Shipment\u003c\/strong\u003e — Ships ready to power on, reducing on-site integration labor and commissioning time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e208\/240V or 230V Input Support\u003c\/strong\u003e — Configurable for North American or international commercial power infrastructure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eToolless Blanking Panels Included\u003c\/strong\u003e — Maintains proper rack airflow across unused rack space for effective thermal management.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eGovernment space edge computing deployments requiring redundant UPS protection\u003c\/li\u003e\n\u003cli\u003eBroadcast studio remote or auxiliary equipment rooms needing self-contained power infrastructure\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space or multi-purpose facility edge IT closets in distributed enterprise networks\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;min-width:480px;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;border-bottom:1px solid #ccc;padding:6px;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"text-align:left;border-bottom:1px solid #ccc;padding:6px;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eUPS Configuration\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e(2) 6 kVA UPS systems, N+N redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eRack Capacity\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e34U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e208\/240V or 230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003ePDUs\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e(2) Metered PDUs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eNetwork Management\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eBlanking Panels\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e(34) 1U toolless blanking panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e538 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eShipping\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eAssembled and tested, ships within 3 business days of order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;\"\u003eCompliance\u003c\/td\u003e\n\u003ctd style=\"padding:6px;\"\u003eRoHS certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eDoes the MDA3F34UPX00000 arrive fully assembled?\u003c\/h3\u003e\u003cp\u003eYes. This EdgeReady micro data center ships assembled and tested, typically within three business days of order receipt, rather than requiring on-site rack, UPS, and PDU integration.\u003c\/p\u003e\u003ch3\u003eWhat redundancy does the dual UPS configuration provide?\u003c\/h3\u003e\u003cp\u003eThe two 6 kVA UPS systems operate in an N+N redundant configuration, meaning either unit can independently support the protected load if the other requires maintenance or experiences a fault.\u003c\/p\u003e\u003ch3\u003eCan the network management features be monitored remotely?\u003c\/h3\u003e\u003cp\u003eYes. The included network management functionality allows remote monitoring of UPS status and power events, which is useful for organizations managing multiple edge or branch locations from a central IT or facilities team.\u003c\/p\u003e\u003ch3\u003eWhat input voltage does this unit support?\u003c\/h3\u003e\u003cp\u003eThe MDA3F34UPX00000 is rated for 208\/240V or 230V input, covering both North American commercial power and international voltage standards.\u003c\/p\u003e\u003ch3\u003eIs this suitable for an AV integration project at a remote site?\u003c\/h3\u003e\u003cp\u003eYes. Because it arrives pre-assembled with power distribution and redundant UPS protection built in, it is well suited for branch offices, remote facilities, or auxiliary equipment rooms supporting AV and IT infrastructure without dedicated on-site technical staff.\u003c\/p\u003e\u003ch3\u003eWhat warranty and support does Eaton provide on this unit?\u003c\/h3\u003e\u003cp\u003eContact Creation Networks for complete manufacturer warranty terms and service plan options for this assembled micro data center configuration.\u003c\/p\u003e\u003ch3\u003eDoes Creation Networks assist with site planning for this unit?\u003c\/h3\u003e\u003cp\u003eYes. Contact Creation Networks to review power, space, and cooling requirements for your specific deployment before ordering.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":48159971016940,"sku":"MDA3F34UPX00000","price":17284.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/mda3f34upx00000.jpg?v=1786678453","url":"https:\/\/creationnetworks.net\/products\/eaton-mda3f34upx00000-edgeready-micro-data-center-34u-2-6-kva-ups-systems-n-n-network-management-and-dual-pdus-208-240v-or-230v-assembled-tested-unit","provider":"Creation Networks","version":"1.0","type":"link"}