{"product_id":"eaton-mbp11k208g2-9px-g2-maintenance-bypass-for-select-8kva-to-11kva-9px-ups-systems","title":"Eaton MBP11K208G2 – 9PX G2 Maintenance Bypass Panel","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Eaton MBP11K208G2 is a maintenance bypass panel built for facilities running an Eaton 9PX G2 UPS between 8kVA and 11kVA that cannot tolerate a power interruption during service. It routes utility power directly to connected loads while the UPS is pulled offline for battery replacement, firmware updates, or scheduled maintenance, making it a standard part of any commercial UPS installation or data center power distribution plan. Integrators sizing a 9PX G2 deployment for a server room, network closet, or data center use this bypass to meet uptime requirements without adding a second UPS. It supports hardwired input and output with four L6-30R output receptacles for straightforward integration into existing rack power distribution.\u003c\/p\u003e\n\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eFacilities that depend on continuous uptime cannot afford to shut down critical loads every time a UPS needs service. The MBP11K208G2 solves this by giving technicians a manual bypass path around the 9PX G2 UPS, so maintenance, capacity upgrades, or unit replacement can happen without dropping power to connected servers, switches, or storage arrays. This is a common requirement in commercial UPS installation projects where the client's uptime requirements do not allow planned outages.\u003c\/p\u003e\n\u003cp\u003eThe unit is a 0U rear-mount design, meaning it does not consume dedicated rack space on its own and is intended to mount behind or alongside the UPS it protects, which keeps rack elevation clean in a data center or network closet buildout. It ships with a rack mounting kit and can also be configured for tower or wall installation, giving integrators flexibility depending on the equipment room layout.\u003c\/p\u003e\n\u003cp\u003eOutput is delivered through four hardwired NEMA L6-30R receptacles rated to support the full 11 kW load capacity of the largest compatible 9PX G2 unit, at 208\/220\/230\/240V AC. The panel is designed exclusively for the 9PX G2 family, including the 9PX8KG2, 9PX8KTF5G2, 9PX11KG2, 9PX11KTF11G2, and 9PX11KTF5G2 models, so integrators should confirm UPS compatibility before specifying this bypass for a job. Because it is hardwired on both input and output, installation should be performed or verified by a licensed electrician as part of the overall power distribution and UPS installation scope.\u003c\/p\u003e\n\u003cp\u003eFor data center and network closet deployments where downtime has a direct operational cost, this bypass panel is a low-cost way to build serviceability into the power path from day one, rather than retrofitting it after the first battery replacement forces an outage.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance bypass function\u003c\/strong\u003e — routes utility power around the 9PX G2 UPS so maintenance and battery replacement do not require a load shutdown.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0U rear-mount form factor\u003c\/strong\u003e — installs behind or alongside the UPS without consuming additional rack space in the enclosure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack, tower, or wall mounting\u003c\/strong\u003e — adapts to the physical layout of the server room, network closet, or data center it is installed in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFour L6-30R hardwired outlets\u003c\/strong\u003e — supports commercial-grade load connections up to the full rated capacity of the paired UPS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e11 kW load capacity\u003c\/strong\u003e — matched to 8kVA-11kVA 9PX G2 UPS systems for straightforward capacity planning.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBroad voltage compatibility\u003c\/strong\u003e — supports 208V, 220V, 230V, and 240V AC output for varied commercial electrical configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncluded mounting hardware\u003c\/strong\u003e — ships with a rack mounting kit to simplify installation during a UPS system deployment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOSHPD seismic certification\u003c\/strong\u003e — suitable for installations in regions requiring seismic-rated equipment mounting, including government and healthcare facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eData center\u003c\/li\u003e\n\u003cli\u003eNetwork closet\u003c\/li\u003e\n\u003cli\u003eServer room\u003c\/li\u003e\n\u003cli\u003eGovernment space\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ SKU\u003c\/td\u003e\n\u003ctd\u003eMBP11K208G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e5.1 in x 11.2 in x 5.1 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack space\u003c\/td\u003e\n\u003ctd\u003e0U rear mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting options\u003c\/td\u003e\n\u003ctd\u003eRack, tower, or wall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput connection\u003c\/td\u003e\n\u003ctd\u003eHardwired\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput connections\u003c\/td\u003e\n\u003ctd\u003e4 x NEMA L6-30R, hardwired\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad capacity\u003c\/td\u003e\n\u003ctd\u003e11 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage\u003c\/td\u003e\n\u003ctd\u003e208V \/ 220V \/ 230V \/ 240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible UPS models\u003c\/td\u003e\n\u003ctd\u003e9PX8KG2, 9PX8KTF5G2, 9PX11KG2, 9PX11KTF11G2, 9PX11KTF5G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003ecUL Listed, NOM, OSHPD Seismic Certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e3-year limited\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs this bypass compatible with the original 9PX (non-G2) UPS series?\u003c\/strong\u003e\u003cbr\u003eNo. The MBP11K208G2 is designed specifically for the 9PX G2 generation of UPS units (9PX8KG2, 9PX11KG2, and related TF variants). The original 9PX series uses a different bypass model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit require an electrician to install?\u003c\/strong\u003e\u003cbr\u003eYes. Both the input and output connections are hardwired, so installation should be performed by a licensed electrician as part of the facility's power distribution work.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I service the UPS while the bypass is active?\u003c\/strong\u003e\u003cbr\u003eYes. That is the core function of this panel — it routes utility power directly to the load so the UPS can be powered down for battery replacement, firmware updates, or unit swaps without interrupting connected equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow much rack space does this unit use?\u003c\/strong\u003e\u003cbr\u003eNone on its own. It is a 0U rear-mount design intended to install behind or alongside the UPS rather than occupying a dedicated rack position.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat load capacity does this bypass support?\u003c\/strong\u003e\u003cbr\u003eUp to 11 kW, matching the largest 9PX G2 UPS models it is designed to pair with (8kVA to 11kVA).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat warranty does Eaton provide on this product?\u003c\/strong\u003e\u003cbr\u003eEaton backs the MBP11K208G2 with a 3-year limited warranty.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this suitable for a data center with seismic mounting requirements?\u003c\/strong\u003e\u003cbr\u003eYes. The unit carries OSHPD seismic certification, making it suitable for installations in California and other regions with seismic mounting codes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat outlet type does the bypass provide for connected equipment?\u003c\/strong\u003e\u003cbr\u003eFour hardwired NEMA L6-30R receptacles are provided for load connections.\u003c\/p\u003e\n","brand":"Eaton","offers":[{"title":"Default Title","offer_id":48159967281388,"sku":"MBP11K208G2","price":1049.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/mbp11k208g2.jpg?v=1786678329","url":"https:\/\/creationnetworks.net\/products\/eaton-mbp11k208g2-9px-g2-maintenance-bypass-for-select-8kva-to-11kva-9px-ups-systems","provider":"Creation Networks","version":"1.0","type":"link"}