{"product_id":"eaton-evmi1530x-metered-input-rack-pdu","title":"Eaton EVMI1530X – G4 3-Phase Metered PDU 8.6kW","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe Eaton EVMI1530X is a 0U vertical, 3-phase metered rack PDU from Eaton's G4 platform, built for server and network racks running on 208V 3-phase circuits with a NEMA L15-30P input. It combines a large outlet count with Gigabit-speed network monitoring. Buyers researching a 3-phase metered PDU, G4 rack PDU, or L15-30P input PDU for a data center rack will find this model suited to modern, cascadable PDU deployments. It fits data center racks, server rooms, and network cabinets standardizing on Eaton's G4 platform.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eThe EVMI1530X draws 208V 3-phase power through a NEMA L15-30P plug on a 10 ft. cord, rated for 30A input and up to 8.6kW total output capacity, with a maximum of 24A per output phase. It delivers 42 outlets — 24 IEC C13 and 18 IEC C39 combo receptacles accepting both C14 and C20 corded devices — spread across three low-profile 20A breakers, each protecting two outlet banks independently so a fault on one bank does not take down the whole PDU. The Eaton Gigabit Network Module G4 provides embedded cybersecurity and Ethernet\/serial connectivity, and the unit is SNMP compatible for integration with existing network monitoring platforms. An onboard LCD pixel display reports current, voltage, power, and energy readings at ±1% accuracy, and the PDU can be cascaded with up to 40 other units under individual IP addresses, simplifying management of large multi-rack deployments. The aluminum, toolless-mount 0U vertical chassis measures roughly 68 inches tall, keeping all 42 outlets accessible along the rack rail. This PDU is a strong fit for data centers and server rooms that need 3-phase metered power distribution with modern network management and per-bank circuit protection.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e8.6kW 3-Phase Capacity\u003c\/strong\u003e — Delivers substantial power across 42 outlets from a 208V circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e42 Outlets (24 C13 \/ 18 C39)\u003c\/strong\u003e — Combo receptacles accept both C14 and C20 corded equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree Independent 20A Breakers\u003c\/strong\u003e — Per-bank circuit protection limits the impact of a single fault.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEaton Gigabit Network Module G4\u003c\/strong\u003e — Embedded cybersecurity with Ethernet\/serial connectivity and SNMP support.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLCD Pixel Display, ±1% Accuracy\u003c\/strong\u003e — Local readout of current, voltage, power, and energy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCascade up to 40 PDUs\u003c\/strong\u003e — Each unit keeps an individual IP address for simplified multi-rack management.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e208V, 3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Input Current\u003c\/td\u003e\n\u003ctd\u003e30A (24A per output phase max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Plug\u003c\/td\u003e\n\u003ctd\u003eNEMA L15-30P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCord Length\u003c\/td\u003e\n\u003ctd\u003e10 ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Output Power\u003c\/td\u003e\n\u003ctd\u003e8.6kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Receptacles\u003c\/td\u003e\n\u003ctd\u003e24x C13, 18x C39 combo (42 total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Protection\u003c\/td\u003e\n\u003ctd\u003e3x 20A low-profile breakers (per two outlet banks)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003e0U, vertical, aluminum chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e68.1 in x 2.09 in x 2.08 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e16.54 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Module\u003c\/td\u003e\n\u003ctd\u003eEaton Gigabit Network Module G4, SNMP compatible, cascade up to 40 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eLCD pixel display, ±1% accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":47865657065708,"sku":"EVMI1530X","price":1495.61,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/EVMI1530X_0_f5c8f983-785b-4ba0-bf6c-b85b08fe5c18.jpg?v=1786644872","url":"https:\/\/creationnetworks.net\/products\/eaton-evmi1530x-metered-input-rack-pdu","provider":"Creation Networks","version":"1.0","type":"link"}