{"product_id":"eaton-emit07-10-metered-input-rack-pdu","title":"Eaton EMIT07-10 – 208V Metered PDU 18 C13 Outlets","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe Eaton EMIT07-10 metered rack PDU is an 18-outlet, 208V single-phase unit built for server racks that need maximum C13 outlet density from a single 1U chassis. It is designed for data center and colocation cabinet deployments running large numbers of standard rack servers and network appliances. For integrators planning a high-outlet-count metered PDU installation without moving to a mixed C13\/C19 layout, the EMIT07-10 offers the highest C13-only outlet count in the EMIT platform.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/EMIT07-10_C.jpg?v=1782802196\" alt=\"Eaton EMIT07-10 rack PDU\" style=\"max-width:100%;height:auto;\"\u003e\u003cp\u003eThe EMIT07-10 is a 1U, 200-240V, 24A metered input rack PDU with eighteen IEC C13 output receptacles, delivering up to 5.76 kW of distributed power through a single NEMA L6-30P input. Its all-C13 configuration is suited to server racks and colocation cabinets populated primarily with standard 1U and 2U servers, storage nodes, and network appliances that use C14 power cords. As a metered input PDU, it reports total input current draw, giving IT and facilities teams the visibility needed to avoid overloading a 24A circuit as additional equipment is added to the rack over time. The unit's twist-lock L6-30P input plug provides a secure connection appropriate for the higher current draw associated with eighteen active outlets. Its 1U horizontal form factor means the additional outlet count does not come at the cost of extra rack space, which matters in fully populated data center and colocation cabinet elevations. Rated for continuous operation across a 0° to 60°C range, the unit performs reliably in both tightly conditioned data centers and less controlled server rooms. UL listing supports specification in commercial deployments with documented compliance requirements. A 3-year limited warranty backs the EMIT07-10 for long-term production use, and its single-phase metered-only design keeps acquisition cost lower than switched or per-outlet metered alternatives for teams that only need circuit-level visibility.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEighteen C13 Outlets\u003c\/strong\u003e — Eighteen IEC C13 receptacles provide the highest all-C13 outlet count in the EMIT family, ideal for racks dense with standard servers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e208V, 24A Input Capacity\u003c\/strong\u003e — The 200-240V, 24A input delivers up to 5.76 kW, supporting a large number of connected devices from one circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eL6-30P Twist-Lock Input\u003c\/strong\u003e — A locking NEMA L6-30P input plug provides a secure connection for the higher current draw of an 18-outlet PDU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1U Rack-Mount Form Factor\u003c\/strong\u003e — The compact 1U chassis maximizes outlet count without consuming additional rack units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Operating Temperature Range\u003c\/strong\u003e — Rated from 0° to 60°C, the unit tolerates both conditioned data centers and less tightly controlled server rooms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL Listed Construction\u003c\/strong\u003e — UL listing supports specification in commercial deployments requiring documented safety compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3-Year Limited Warranty\u003c\/strong\u003e — Eaton backs the EMIT07-10 with a 3-year limited warranty for long-term production reliability.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003edata center\u003c\/li\u003e\n\u003cli\u003ecolocation cabinet\u003c\/li\u003e\n\u003cli\u003eserver room\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200-240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Current\/Amperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Plug\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNEMA L6-30P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Receptacles\/Outlets\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e(18) IEC C13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Rating (kW\/VA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.76 kW max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\/Form Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1U rack-mount, horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitoring Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMetered (input current only, no per-outlet metering or switching)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19 in W x 1.69 in H x 8 in D; 9.1 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-year limited warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eHow many devices can connect to the EMIT07-10?\u003c\/h3\u003e\u003cp\u003eThe unit provides 18 C13 outlets, supporting up to 18 connected devices, subject to the total 24A\/5.76kW input rating and each device's actual draw.\u003c\/p\u003e\u003ch3\u003eWhat input circuit is required?\u003c\/h3\u003e\u003cp\u003eA dedicated 200-240V single-phase circuit rated at 24A or higher, terminated with a NEMA L6-30R receptacle.\u003c\/p\u003e\u003ch3\u003eDoes the EMIT07-10 support C19-terminated equipment?\u003c\/h3\u003e\u003cp\u003eNo. All 18 outlets on this model are C13; equipment requiring a C20 power cord should use a mixed-outlet model such as the EMIT04-10 or EMIT06-10.\u003c\/p\u003e\u003ch3\u003eDoes this PDU offer per-outlet control or metering?\u003c\/h3\u003e\u003cp\u003eNo. It reports total input current only and does not provide per-outlet metering, load shedding, or remote switching.\u003c\/p\u003e\u003ch3\u003eIs the EMIT07-10 suitable for a fully populated data center rack?\u003c\/h3\u003e\u003cp\u003eYes. Its 18-outlet, all-C13 design and 1U form factor make it well suited for server racks and colocation cabinets with a high density of standard IT equipment.\u003c\/p\u003e\u003ch3\u003eCan it be monitored over a network?\u003c\/h3\u003e\u003cp\u003eThe base configuration is a metered-input PDU with local metering; contact Eaton or Creation Networks to confirm network monitoring options available for this specific model.\u003c\/p\u003e\u003ch3\u003eWhat warranty does Eaton provide?\u003c\/h3\u003e\u003cp\u003eEaton provides a 3-year limited warranty on the EMIT07-10. Contact Eaton or Creation Networks for full terms and support.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":47865657196780,"sku":"EMIT07-10","price":972.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/EMIT07-10_C.jpg?v=1782802196","url":"https:\/\/creationnetworks.net\/products\/eaton-emit07-10-metered-input-rack-pdu","provider":"Creation Networks","version":"1.0","type":"link"}