{"product_id":"eaton-emi338-06-metered-input-rack-pdu","title":"Eaton EMI338-06 – 60-Outlet Metered Rack PDU","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe Eaton EMI338-06 metered input rack PDU is designed for high-density data center and colocation cabinet installations that need extensive outlet capacity alongside 3-phase load monitoring. This metered rack PDU combines 48 C13 and 12 C19 outlets in a single 0U vertical unit, making it well suited for rack PDU installation in cabinets mixing servers with higher-draw equipment such as blade chassis or storage arrays. Facilities managers and integrators use this class of 3-phase PDU for server room power distribution where amperage visibility and electrical compliance are required.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eThe Eaton EMI338-06 is a 3-phase, 0U vertical metered input rack PDU rated for 200-240V at 48A, delivering up to 17.3 kW through a combined total of 60 outlets: 48 IEC C13 and 12 IEC C19 receptacles. The mixed outlet configuration accommodates both standard servers and network switches on C13 cords alongside higher-current equipment such as blade servers, storage enclosures, and some UPS units that terminate on C19. Input connects through an IEC 60309 460P9 plug, and a digital display on the PDU faceplate provides local readout of voltage and current for verifying load balance during rack PDU installation. The 0U vertical mounting profile runs the length of the rack frame, keeping all 60 outlets available without consuming horizontal rack unit space, which is a priority in dense colocation cabinet and data center deployments. An Ethernet monitoring interface allows remote polling of power data, supporting centralized oversight across multiple racks in a server room or colocation facility. Because the EMI338-06 provides more outlets and a mixed C13\/C19 configuration than a standard metered PDU, it is commonly specified for cabinets consolidating multiple device types onto a single 3-phase circuit, reducing the need for secondary power strips.\u003c\/p\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/EMI338-06_0_a8b72ffe-3ead-4946-a04b-667f72ff561f.jpg?v=1786645569\" alt=\"Eaton EMI338-06 0U vertical 60-outlet metered rack PDU\"\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e60 Total Outlets\u003c\/strong\u003e — 48 C13 and 12 C19 receptacles support mixed equipment loads on a single PDU, reducing the need for supplemental power strips.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Local Metering\u003c\/strong\u003e — A built-in display shows input voltage and current at the rack for quick verification during commissioning.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3-Phase 17.3 kW Capacity\u003c\/strong\u003e — Power is distributed across three phases, supporting higher aggregate loads than single-phase PDUs of similar size.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0U Vertical Mounting\u003c\/strong\u003e — The PDU mounts along the rack frame without occupying rack unit space needed for servers and switches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Monitoring Interface\u003c\/strong\u003e — Remote access to load data supports centralized monitoring across a data center or colocation environment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60309 460P9 Input\u003c\/strong\u003e — A widely available industrial-grade input plug simplifies electrical planning and whip sourcing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL Listed Construction\u003c\/strong\u003e — Third-party safety certification supports use in commercial and government facility deployments.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eData center\u003c\/li\u003e\n\u003cli\u003eColocation facility\u003c\/li\u003e\n\u003cli\u003eServer room\u003c\/li\u003e\n\u003cli\u003eNetwork closet\u003c\/li\u003e\n\u003cli\u003eGovernment space\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e200-240V, 50-60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\/Amperage\u003c\/td\u003e\n\u003ctd\u003e48A, 3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Plug\u003c\/td\u003e\n\u003ctd\u003eIEC 60309 460P9 (3P+N+E)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Receptacles\/Outlets\u003c\/td\u003e\n\u003ctd\u003e48 x IEC C13, 12 x IEC C19 (60 total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Rating (kW\/VA)\u003c\/td\u003e\n\u003ctd\u003e17.3 kW max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\/Form Factor\u003c\/td\u003e\n\u003ctd\u003e0U, vertical rack-mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring Type\u003c\/td\u003e\n\u003ctd\u003eMetered (local digital display plus Ethernet remote monitoring)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 63.2 in (L) x 4.1 in (W) x 2.09 in (H); 17.6 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e3-year limited warranty (Eaton)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat equipment can connect to the EMI338-06's outlets?\u003c\/h3\u003e\u003cp\u003eThe 48 C13 outlets support standard servers, switches, and network appliances with C14 power cords, while the 12 C19 outlets accommodate higher-draw equipment such as blade chassis and some storage arrays with C20 cords.\u003c\/p\u003e\u003ch3\u003eWhat electrical circuit does this PDU require?\u003c\/h3\u003e\u003cp\u003eIt requires a 3-phase, 200-240V, 48A circuit terminated with an IEC 60309 460P9 connector. Confirm this matches your facility's available electrical service before ordering.\u003c\/p\u003e\u003ch3\u003eHow is the EMI338-06 mounted in a rack cabinet?\u003c\/h3\u003e\u003cp\u003eIt mounts vertically in a 0U configuration along the rack frame, keeping all 60 outlets accessible without using horizontal rack unit space.\u003c\/p\u003e\u003ch3\u003eCan this PDU be monitored remotely?\u003c\/h3\u003e\u003cp\u003eYes. An Ethernet interface allows remote polling of input voltage and current, supporting integration into a broader data center or colocation monitoring setup.\u003c\/p\u003e\u003ch3\u003eDoes the EMI338-06 support individual outlet switching?\u003c\/h3\u003e\u003cp\u003eNo. This is a metered input model, providing total load visibility but not per-outlet control. Eaton's switched or managed models are the appropriate choice when outlet-level control is required.\u003c\/p\u003e\u003ch3\u003eWhat is the warranty on this Eaton PDU?\u003c\/h3\u003e\u003cp\u003eEaton provides a 3-year limited warranty on the EMI338-06. Contact Eaton or Creation Networks for complete warranty terms.\u003c\/p\u003e\u003ch3\u003eCan Creation Networks help determine if this PDU fits my cabinet's equipment load?\u003c\/h3\u003e\u003cp\u003eYes. Creation Networks can help review your equipment list and outlet requirements to confirm the EMI338-06's mixed C13\/C19 configuration matches your planned rack PDU installation.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":47865657360620,"sku":"EMI338-06","price":3096.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/EMI338-06_0_a8b72ffe-3ead-4946-a04b-667f72ff561f.jpg?v=1786645569","url":"https:\/\/creationnetworks.net\/products\/eaton-emi338-06-metered-input-rack-pdu","provider":"Creation Networks","version":"1.0","type":"link"}