{"product_id":"eaton-emi323-06-metered-input-rack-pdu","title":"Eaton EMI323-06 – 38-Outlet Metered Rack PDU","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Eaton EMI323-06 metered input rack PDU is built for data center and colocation cabinet deployments that need reliable 3-phase power distribution with real-time load visibility. As a metered rack PDU, it gives integrators and facilities managers a digital readout of total input current and voltage, supporting proper load balancing during rack PDU installation. With 38 C13 outlets and a 0U vertical form factor, it is a practical choice for high-density server room power distribution where cabinet space is limited. This unit suits any commercial AV\/IT deployment where amperage monitoring and 3-phase PDU deployment are required for compliance or capacity planning.\u003c\/p\u003e\n\n\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe Eaton EMI323-06 is a 3-phase, 0U vertical metered input rack PDU rated for 200-240V input at 48A, delivering up to 17.3 kW of usable power through 38 IEC C13 outlets. It connects via an IEC 60309 460P9 (3P+N+E) input plug and includes a digital display at the PDU faceplate for local monitoring of input voltage and current, so technicians can confirm load conditions during commissioning without a separate meter. This makes it well suited for rack PDU installation in colocation cabinets, network closets, and enterprise server rooms where 3-phase circuits are common and load balancing across phases is a requirement for uptime.\u003c\/p\u003e\n\u003cp\u003eBecause it mounts vertically in a 0U configuration, the EMI323-06 runs the full height of a rack enclosure along the side rail, preserving horizontal U space for servers, switches, and other active equipment. This is a common configuration for data center power distribution where rack real estate is at a premium and IT teams want a single PDU to feed an entire cabinet of C13-terminated equipment cords. The unit includes an Ethernet interface alongside its local display, allowing remote polling of load data from a network management workstation, which supports basic environmental and power monitoring practices in commercial data center and colocation environments.\u003c\/p\u003e\n\u003cp\u003eIntegrators sourcing an Eaton metered PDU for a new build-out or a cabinet refresh should confirm available input circuit type (3-phase, 200-240V) and outlet count needs before ordering, since the EMI323-06's 38-outlet, C13-only configuration is best matched to racks populated primarily with servers, switches, and low-draw network equipment rather than mixed C13\/C19 loads.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Local Metering\u003c\/strong\u003e — An integrated display shows input voltage and current directly at the rack, letting technicians verify load balance during installation without external test equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3-Phase 17.3 kW Capacity\u003c\/strong\u003e — The unit distributes up to 17.3 kW across three phases, supporting higher-density cabinets than single-phase alternatives.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e38 C13 Outlets\u003c\/strong\u003e — A high outlet count accommodates full-cabinet server and switch deployments without daisy-chaining additional power strips.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0U Vertical Mounting\u003c\/strong\u003e — The vertical form factor mounts to the rack frame without consuming rack unit space needed for active equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Monitoring Interface\u003c\/strong\u003e — Remote network polling of power data supports centralized monitoring across multiple cabinets in a data center or colocation facility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60309 460P9 Input\u003c\/strong\u003e — A standard industrial-grade 3-phase plug simplifies sourcing of matching whips and receptacles during electrical rough-in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL Listed Construction\u003c\/strong\u003e — Independent safety certification supports compliance requirements common in commercial and government facility deployments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eData center\u003c\/li\u003e\n\u003cli\u003eColocation cabinet\u003c\/li\u003e\n\u003cli\u003eServer room\u003c\/li\u003e\n\u003cli\u003eNetwork closet\u003c\/li\u003e\n\u003cli\u003eGovernment space\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200-240V, 50-60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Current\/Amperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48A, 3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Plug\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60309 460P9 (3P+N+E)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Receptacles\/Outlets\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e38 x IEC C13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Rating (kW\/VA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.3 kW max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\/Form Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0U, vertical rack-mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitoring Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMetered (local digital display plus Ethernet remote monitoring)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot published by manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-year limited warranty (Eaton)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eIs the EMI323-06 compatible with standard C13 server power cords?\u003c\/h3\u003e\n\u003cp\u003eYes. All 38 outlets on the EMI323-06 are IEC C13 receptacles, compatible with the standard C14 power cords included with most servers, switches, and network appliances.\u003c\/p\u003e\n\u003ch3\u003eWhat electrical service does this PDU require?\u003c\/h3\u003e\n\u003cp\u003eThe EMI323-06 requires a 3-phase, 200-240V, 48A circuit terminated with an IEC 60309 460P9 receptacle. Confirm your facility's electrical infrastructure supports this configuration before ordering.\u003c\/p\u003e\n\u003ch3\u003eHow is this unit mounted in a rack?\u003c\/h3\u003e\n\u003cp\u003eIt mounts vertically in a 0U configuration along the side rail of a standard rack enclosure, preserving horizontal rack unit space for servers and network equipment.\u003c\/p\u003e\n\u003ch3\u003eCan I monitor this PDU remotely as part of a larger AV\/IT monitoring system?\u003c\/h3\u003e\n\u003cp\u003eYes. The unit includes an Ethernet interface for remote polling of voltage and current readings, which can be integrated into broader data center or facility monitoring workflows.\u003c\/p\u003e\n\u003ch3\u003eDoes this PDU support outlet-level switching or control?\u003c\/h3\u003e\n\u003cp\u003eNo. The EMI323-06 is a metered input model, meaning it reports total input load but does not provide individual outlet switching. For outlet-level control, an Eaton switched or managed ePDU model is required.\u003c\/p\u003e\n\u003ch3\u003eWhat warranty does Eaton provide on this product?\u003c\/h3\u003e\n\u003cp\u003eEaton backs the EMI323-06 with a 3-year limited warranty. Contact Eaton or Creation Networks for full warranty terms and RMA procedures.\u003c\/p\u003e\n\u003ch3\u003eDoes Creation Networks provide installation support for this PDU?\u003c\/h3\u003e\n\u003cp\u003eCreation Networks' team can advise on rack PDU installation planning, including circuit requirements and outlet allocation, for commercial AV\/IT and data center deployments.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":47865657426156,"sku":"EMI323-06","price":2762.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/EMI323-06_0_725defed-a559-4533-8033-66d847a42a7f.jpg?v=1786645848","url":"https:\/\/creationnetworks.net\/products\/eaton-emi323-06-metered-input-rack-pdu","provider":"Creation Networks","version":"1.0","type":"link"}