{"product_id":"eaton-emi310-10-metered-input-rack-pdu","title":"Eaton EMI310-10 – Three-Phase Metered Rack PDU 8.64kW","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Eaton EMI310-10 three-phase metered rack PDU is built for data center and colocation cabinet deployments that need higher power density than a single-phase circuit can provide. As a 3-phase metered PDU, it delivers 8.64 kW across 37 outlets while giving integrators real-time input load data for rack PDU installation and ongoing capacity planning. This unit is a common specification for enterprise data centers and colocation facilities consolidating dense server and network loads onto a single 3-phase circuit rather than multiple single-phase PDUs.\u003c\/p\u003e\n\n\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/EMI310-10_C.jpg?v=1782802197\" alt=\"Eaton EMI310-10 rack PDU\" style=\"max-width:100%;height:auto;\"\u003e\n\u003cp\u003eThe Eaton EMI310-10 is a 3-phase, metered input rack PDU rated for 120\/208V input at 24A, delivering up to 8.64 kW of usable power. It provides 37 total outlets: 30 IEC 60320 C13, 6 IEC 60320 C19, and 1 NEMA 5-20R receptacle, giving integrators a versatile outlet mix for servers, switches, and network appliances that terminate on either IEC or NEMA power cords. Input connects through a NEMA L21-30P plug on a 10-foot cord, a standard 3-phase wye connector widely used in North American data center electrical infrastructure. A local display and remote monitoring via Ethernet and RS-232 give facilities and IT staff visibility into aggregate input load, supporting proper phase balancing during rack PDU installation. Because power is distributed across three phases rather than a single circuit, the EMI310-10 can support a higher overall load per rack than a comparable single-phase unit of similar outlet count, which is a common requirement in colocation cabinet and enterprise data center deployments consolidating equipment onto fewer, higher-capacity circuits. The 0U vertical mounting profile runs the height of a standard 42U-class rack enclosure, keeping the full 37-outlet count accessible without consuming horizontal rack unit space needed for servers and switches. Integrators specifying this PDU for a data center or colocation cabinet build should confirm the facility supports 120\/208V 3-phase wye service and the L21-30P connector, and should plan equipment placement to balance load reasonably evenly across the three phases feeding the unit.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e37-Outlet Mixed Configuration\u003c\/strong\u003e — 30 C13, 6 C19, and 1 NEMA 5-20R outlet accommodate a wide range of servers, switches, and network appliances on one PDU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3-Phase 8.64 kW Capacity\u003c\/strong\u003e — Distributing power across three phases supports a higher overall rack load than a comparable single-phase PDU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocal and Remote Metering\u003c\/strong\u003e — A local display plus Ethernet and RS-232 connectivity provide both on-site and network-based visibility into input load.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0U Vertical Mounting\u003c\/strong\u003e — The PDU installs along the rack frame, preserving rack unit space for active equipment in standard 42U-class enclosures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNEMA L21-30P Input Plug\u003c\/strong\u003e — A standard 3-phase wye connector simplifies electrical planning in facilities with existing 3-phase infrastructure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL Listed and TAA Compliant\u003c\/strong\u003e — Independent certification and trade compliance support commercial and government facility deployments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3-Year Limited Warranty\u003c\/strong\u003e — Backed by Eaton's standard rack PDU warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eData center\u003c\/li\u003e\n\u003cli\u003eColocation cabinet\u003c\/li\u003e\n\u003cli\u003eServer room\u003c\/li\u003e\n\u003cli\u003eNetwork closet\u003c\/li\u003e\n\u003cli\u003eGovernment space\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\/208V AC, 3-phase wye, 50-60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Current\/Amperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Plug\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNEMA L21-30P, 10 ft cord\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Receptacles\/Outlets\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37 total: (30) IEC 60320 C13, (6) IEC 60320 C19, (1) NEMA 5-20R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Rating (kW\/VA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.64 kW max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\/Form Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0U, vertical rack-mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitoring Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMetered (local display plus Ethernet\/RS-232 remote monitoring; no individual outlet switching)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e66.5 in H x 2.1 in W x 2.05 in D; 17.61 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed, TAA Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-year limited warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat electrical circuit does the EMI310-10 require?\u003c\/h3\u003e\n\u003cp\u003eIt requires a 120\/208V, 3-phase wye circuit rated for 24A, terminated with a NEMA L21-30P receptacle. Confirm this matches your facility's available electrical service before ordering.\u003c\/p\u003e\n\u003ch3\u003eCan I mix IEC and NEMA-corded equipment on this PDU?\u003c\/h3\u003e\n\u003cp\u003eYes. The 37-outlet configuration includes 30 C13, 6 C19, and 1 NEMA 5-20R receptacle, supporting both IEC-terminated servers and equipment that ships with standard NEMA power cords.\u003c\/p\u003e\n\u003ch3\u003eWhy choose a 3-phase PDU instead of single-phase for this rack?\u003c\/h3\u003e\n\u003cp\u003eA 3-phase circuit distributes load across three separate phases, allowing the EMI310-10 to support a higher overall power capacity per rack than a comparable single-phase PDU, which is useful in dense data center and colocation cabinet deployments.\u003c\/p\u003e\n\u003ch3\u003eCan this PDU be monitored remotely?\u003c\/h3\u003e\n\u003cp\u003eYes. It includes an Ethernet interface and RS-232 serial port for remote monitoring of input load alongside its local display.\u003c\/p\u003e\n\u003ch3\u003eDoes the EMI310-10 support individual outlet switching?\u003c\/h3\u003e\n\u003cp\u003eNo. This is a metered input model, reporting total load without per-outlet control. Eaton's switched or managed PDU models are available where outlet-level control is required.\u003c\/p\u003e\n\u003ch3\u003eWhat warranty does this PDU carry?\u003c\/h3\u003e\n\u003cp\u003eThe EMI310-10 is covered by Eaton's standard 3-year limited warranty. Contact Eaton or Creation Networks for full terms.\u003c\/p\u003e\n\u003ch3\u003eCan Creation Networks help with phase balancing during installation?\u003c\/h3\u003e\n\u003cp\u003eYes. Creation Networks can advise on equipment placement across the PDU's outlets to help balance load evenly across the three phases during rack PDU installation.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":47865657557228,"sku":"EMI310-10","price":1605.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/EMI310-10_C.jpg?v=1782802197","url":"https:\/\/creationnetworks.net\/products\/eaton-emi310-10-metered-input-rack-pdu","provider":"Creation Networks","version":"1.0","type":"link"}